FS GREEN ENERGIES PRIVATE LIMITED FST-M10144G-600 is a 600.0 W STC (570.6 W PTC) Mono-c-Si solar module ranking #1,320 of 21,677 CEC listings (top 6.7%; higher than 93.3% of peers). It delivers 23.44% efficiency, 53.7 V Voc at 25 C, and 57.82 V cold Voc at -10 C (10 panels max per 600 V string).
- STC Wattage
- 600.0 W
- PTC Wattage
- 570.6 W
- Voc @ 25C
- 53.7 V
- Efficiency
- 23.44%
How Does FS GREEN ENERGIES PRIVATE LIMITED FST-M10144G-600 Compare Against Peer CEC Listings?
Solar engineering breakdown for FS GREEN ENERGIES PRIVATE LIMITED FST-M10144G-600: PTC thermal retention, roof footprint, and cold Voc string bounds.
Measured at 600.0 W STC and 570.6 W PTC, FS GREEN ENERGIES PRIVATE LIMITED FST-M10144G-600 sits +215.0 W vs all-CEC median (top 6.7%; higher than 93.3% of peers) among 21,677 listed modules. Power density reaches 234.4 W/m2 (3.53 percentage points above 19.91% CEC median). Higher 53.7 V open-circuit voltage caps 600 V residential strings at 10 panels at 14 F (-10 C), whereas 1,000 V commercial inverters handle up to 17 panels in series. Alternative peer AMPS Solar AMPS-600N-144SW rates 600.0 W.
Where Does FS GREEN ENERGIES PRIVATE LIMITED FST-M10144G-600 Fall Across Listed CEC Models?
Distribution marker showing FS GREEN ENERGIES PRIVATE LIMITED FST-M10144G-600 (600.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define FS GREEN ENERGIES PRIVATE LIMITED FST-M10144G-600?
Dataset percentiles tracking FS GREEN ENERGIES PRIVATE LIMITED FST-M10144G-600 power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for FS GREEN ENERGIES PRIVATE LIMITED FST-M10144G-600?
Benchmark highlights for FS GREEN ENERGIES PRIVATE LIMITED FST-M10144G-600 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
Top 6.7% STC Output
600.0 W STC (+215.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
23.44% Aperture Efficiency
Power density 234.4 W/m2 (3.53 percentage points above 19.91% CEC median). PTC/STC ratio: 95.1% (rank #713).
10 Panels Max @ -10 C (600 V)
Cold Voc reaches 57.82 V at -10 C (578.2 V string) and 58.99 V at -20 C (10 max).
14 Panels = 8,400 W STC
Occupies 35.8 m2 (386 sq ft) producing 7,988 W PTC; NEC 690.8 OCPD floor is 22.25 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 53.7 * (1 + (-0.219/100) * (-10 - 25)) = 57.82 V | OCPD = 1.56 * 14.26 = 22.25 A
Inputs from CEC Modules.csv for FS GREEN ENERGIES PRIVATE LIMITED FST-M10144G-600: Voc=53.7 V, beta_Voc=-0.219%/C, Isc=14.26 A, STC=600.0 W, Area=2.56 m2.
Result: 10 panels max on 600 V (578.2 V); 14 panels for 8 kW (386 sq ft).
What Are the Published CEC Specifications for FS GREEN ENERGIES PRIVATE LIMITED FST-M10144G-600?
Official CEC datasheet figures for FS GREEN ENERGIES PRIVATE LIMITED FST-M10144G-600 (Mono-c-Si) used in utility interconnection and permit reviews.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 600.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 570.6 W (95.1% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 53.7 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 14.26 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 44.71 V / 13.42 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.219 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 23.44% (2.56 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Bifacial glass-glass |
How Many FS GREEN ENERGIES PRIVATE LIMITED FST-M10144G-600 Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many FS GREEN ENERGIES PRIVATE LIMITED FST-M10144G-600 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 10 | 6.0 kW | 276 sq ft | $1,502 | $2,539 |
| 8 kW Class | 14 | 8.4 kW | 386 sq ft | $2,102 | $3,555 |
| 10 kW Class | 17 | 10.2 kW | 468 sq ft | $2,553 | $4,317 |
How Many FS GREEN ENERGIES PRIVATE LIMITED FST-M10144G-600 Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on FS GREEN ENERGIES PRIVATE LIMITED FST-M10144G-600 (57.82 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 58.99 V | 10 panels | 589.9 V | 16 panels |
| -10 C (14 F) | 57.82 V | 10 panels | 578.2 V | 17 panels |
| 0 C (32 F) | 56.64 V | 10 panels | 566.4 V | 17 panels |
| 25 C (77 F STC) | 53.7 V | 11 panels | 590.7 V | 18 panels |
Which Cross-Brand Solar Modules Compare Closest to FS GREEN ENERGIES PRIVATE LIMITED FST-M10144G-600?
Competing CEC solar panels closest to FS GREEN ENERGIES PRIVATE LIMITED FST-M10144G-600 in nameplate wattage and Voc, starting with AMPS Solar AMPS-600N-144SW.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| AMPS Solar AMPS-600N-144SW AMPS Solar |
600.0 W | Tie (0 W) | 53.3 V | 23.44% | 95.0% |
| HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S600OJ HD HYUNDAI ENERGY SOLUTIONS CO LTD |
600.0 W | Tie (0 W) | 54.2 V | 21.74% | 93.3% |
| JA Solar JAM72D40-600/MB-US JA Solar |
600.0 W | Tie (0 W) | 54.3 V | 23.81% | 95.1% |
| CW ENERJ M HEND SL K T CARET VE SANAY ANON M RKET CWT600-144TNB10 CW ENERJ M HEND SL K T CARET VE SANAY ANON M RKET |
600.0 W | Tie (0 W) | 53.05 V | 23.26% | 95.5% |
What Are the Design Limits and Best-Fit Uses for FS GREEN ENERGIES PRIVATE LIMITED FST-M10144G-600?
Evaluate FS GREEN ENERGIES PRIVATE LIMITED FST-M10144G-600 (600.0 W STC, 53.7 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), FS GREEN ENERGIES PRIVATE LIMITED FST-M10144G-600 reaches 58.99 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 14 panels for an 8 kW build require 386 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of FS GREEN ENERGIES PRIVATE LIMITED FST-M10144G-600 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
FS GREEN ENERGIES PRIVATE LIMITED FST-M10144G-600 8 kW Residential Fit
Needs 14 modules (386 sq ft) with a 25 A string OCPD, offsetting ~$2,102/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare AMPS Solar AMPS-600N-144SW.
Bifacial / High-Heat Roof Check
Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 570.6 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for FS GREEN ENERGIES PRIVATE LIMITED FST-M10144G-600 by FS GREEN ENERGIES PRIVATE LIMITED grounded in CEC test data and NEC 690.7/690.8 limits.
How many FS GREEN ENERGIES PRIVATE LIMITED FST-M10144G-600 panels fit on a 600 V winter solar string?
At -10 C (14 F), FS GREEN ENERGIES PRIVATE LIMITED FST-M10144G-600 cold Voc rises from 53.7 V to 57.82 V (beta_Voc -0.219%/C), capping a 600 V string at 10 panels (578.2 V).
How much roof area does an 8 kW array of FS GREEN ENERGIES PRIVATE LIMITED FST-M10144G-600 need?
An 8 kW DC system uses 14 FS GREEN ENERGIES PRIVATE LIMITED FST-M10144G-600 modules (8,400 W STC / 7,988 W PTC), covering roughly 386 sq ft and saving ~$2,102/yr at 18.54 c/kWh.
How does FS GREEN ENERGIES PRIVATE LIMITED FST-M10144G-600 compare against AMPS Solar AMPS-600N-144SW?
FS GREEN ENERGIES PRIVATE LIMITED FST-M10144G-600 outputs 600.0 W STC (53.7 V Voc, rank #1,320 of 21,677), while AMPS Solar AMPS-600N-144SW delivers 600.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)