HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S360XG(BK) — CEC Solar Module Specifications

Manufacturer: HD HYUNDAI ENERGY SOLUTIONS CO LTD Registry: CEC Verified Engineering Specification

HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S360XG(BK) is a 360.0 W STC (336.5 W PTC) Mono-c-Si solar module ranking #12,385 of 21,677 CEC listings (below all-CEC median; higher than 41.3% of peers). It delivers 19.78% efficiency, 41.0 V Voc at 25 C, and 44.6 V cold Voc at -10 C (13 panels max per 600 V string).

STC Wattage
360.0 W
PTC Wattage
336.5 W
Voc @ 25C
41.0 V
Efficiency
19.78%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S360XG(BK) Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S360XG(BK) (Mono-c-Si) residential solar systems.

Homeowners evaluating HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S360XG(BK) need 17 panels for 6 kW or 23 panels (451 sq ft) for an 8 kW array—useful on tight dormer roofs or battery cabins, though 8 kW requires 23 panels (451 sq ft). Under NEC 690.7(A), beta_Voc (-0.251%/C) pushes open-circuit voltage to 44.6 V at 14 F and 45.63 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

Where Does HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S360XG(BK) Fall Across Listed CEC Models?

Comparison of HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S360XG(BK) (360.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S360XG(BK) (360.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCHD HYUNDAI ENERGY : 360.0 W

What Dataset Percentiles Define HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S360XG(BK)?

Relative ranking of HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S360XG(BK) across nameplate watts, 93.5% PTC thermal ratio, and module aperture efficiency.

HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S360XG(BK) Engineering BenchmarksPercentile comparison of HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S360XG(BK) wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage360.0 WPTC/STC Retention93.5%Module Efficiency19.78%

What Do the Dataset Ranks Show for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S360XG(BK)?

Summary of HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S360XG(BK) output rank, 8 kW array size (23 panels), efficiency rating, and 600 V string limit.

Rank #12,385 / 21,677

360.0 W STC · Higher Than 41.3%

360.0 W STC (-25.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #11,263

19.78% Aperture Efficiency

Power density 197.8 W/m2 (0.13 percentage points below 19.91% CEC median). PTC/STC ratio: 93.5% (rank #7,159).

NEC 690.7 Limit

13 Panels Max @ -10 C (600 V)

Cold Voc reaches 44.6 V at -10 C (579.8 V string) and 45.63 V at -20 C (13 max).

8 kW Reference Array

23 Panels = 8,280 W STC

Occupies 41.9 m2 (451 sq ft) producing 7,740 W PTC; NEC 690.8 OCPD floor is 17.47 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 41.0 * (1 + (-0.251/100) * (-10 - 25)) = 44.6 V | OCPD = 1.56 * 11.2 = 17.47 A

Inputs from CEC Modules.csv for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S360XG(BK): Voc=41.0 V, beta_Voc=-0.251%/C, Isc=11.2 A, STC=360.0 W, Area=1.82 m2.

Result: 13 panels max on 600 V (579.8 V); 23 panels for 8 kW (451 sq ft).

What Are the Published CEC Specifications for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S360XG(BK)?

Complete CEC test sheet for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S360XG(BK) including Isc (11.2 A), Voc (41.0 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S360XG(BK).
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 360.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 336.5 W (93.5% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 41.0 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 11.2 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 34.1 V / 10.56 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.251 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 19.78% (1.82 m2) Array roof footprint density
Cell Count & Technology 60 cells (Mono-c-Si) Monofacial backsheet

How Many HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S360XG(BK) Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S360XG(BK).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 17 6.12 kW 333 sq ft $1,532 $2,590
8 kW Class 23 8.28 kW 451 sq ft $2,072 $3,504
10 kW Class 28 10.08 kW 549 sq ft $2,523 $4,266

Which Sibling Wattage & Trim Variants Belong to This HD HYUNDAI ENERGY SOLUTIONS CO LTD Series?

Related HD HYUNDAI ENERGY SOLUTIONS CO LTD power steps and black/silver trims consolidated into this HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S360XG(BK) series guide.

Sibling CEC listings grouped into the HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S360XG(BK) wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S350XG(BK) 350.0 W 326.9 W 40.3 V 33.6 V 19.23%
HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S355XG(BK) 355.0 W 331.7 W 40.6 V 33.9 V 19.51%
HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S360XG(BK) 360.0 W 336.5 W 41.0 V 34.1 V 19.78%
HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S365XG(BK) 365.0 W 341.3 W 41.3 V 34.3 V 20.05%
HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S370XG(BK) 370.0 W 346.1 W 41.5 V 34.6 V 20.33%

How Many HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S360XG(BK) Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S360XG(BK) (41.0 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=41.0V and beta_Voc=-0.251%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 45.63 V 13 panels 593.2 V 21 panels
-10 C (14 F) 44.6 V 13 panels 579.8 V 22 panels
0 C (32 F) 43.57 V 13 panels 566.4 V 22 panels
25 C (77 F STC) 41.0 V 14 panels 574.0 V 24 panels

Which Cross-Brand Solar Modules Compare Closest to HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S360XG(BK)?

Four comparable CEC modules such as DualSun SAS DualSun 360M-120-00 (360.0 W) for side-by-side solar quote checks. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
DualSun SAS DualSun 360M-120-00
DualSun SAS
360.0 W Tie (0 W) 40.9 V 19.89% 93.3%
DualSun SAS DualSun 360M-120-01
DualSun SAS
360.0 W Tie (0 W) 40.9 V 19.89% 93.2%
CSI Solar Co Ltd CS3L-360P
CSI Solar Co Ltd
360.0 W Tie (0 W) 40.6 V 20.11% 92.4%
Apollo Renewables Inc Apollo-M660BH-360BB
Apollo Renewables Inc
360.0 W Tie (0 W) 40.5 V 20.0% 93.6%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S360XG(BK)?

Evaluate HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S360XG(BK) (360.0 W STC, 41.0 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S360XG(BK) reaches 45.63 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 23 panels for an 8 kW build require 451 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 23 panels (451 sq ft).
  • 2026 tax credit baseline: cash residential installs of HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S360XG(BK) carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S360XG(BK) 8 kW Residential Fit

Needs 23 modules (451 sq ft) with a 20 A string OCPD, offsetting ~$2,072/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare DualSun SAS DualSun 360M-120-00.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 336.5 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S360XG(BK) by HD HYUNDAI ENERGY SOLUTIONS CO LTD grounded in CEC test data and NEC 690.7/690.8 limits.

Why is HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S360XG(BK) PTC wattage (336.5 W) lower than STC (360.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 336.5 W PTC (93.5% retention) across HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S360XG(BK)'s 1.82 m2 aperture.

Who should skip HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S360XG(BK) on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 23 HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S360XG(BK) panels (451 sq ft) leave unusable roof gaps vs. DualSun SAS DualSun 360M-120-00.

What is the 1,000 V commercial string limit for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S360XG(BK)?

On 1,000 V commercial inverters at -10 C (44.6 V cold Voc), HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S360XG(BK) fits up to 22 panels per series string.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.