Skip to main content
WireAndSun
Calculators
CEC PV Module

Hansol Technics Co Ltd HS330ND-AN4 — CEC Solar Module Specifications

Manufacturer: Hansol Technics Co Ltd Registry: CEC Verified Engineering Specification

Hansol Technics Co Ltd HS330ND-AN4 is a 330.0 W STC (302.6 W PTC) Multi-c-Si solar module ranking #14,165 of 21,677 CEC listings (below all-CEC median; higher than 32.9% of peers). It delivers 17.06% efficiency, 46.9 V Voc at 25 C, and 51.94 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
330.0 W
PTC Wattage
302.6 W
Voc @ 25C
46.9 V
Efficiency
17.06%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Hansol Technics Co Ltd HS330ND-AN4 Compare Against Peer CEC Listings?

Solar engineering breakdown for Hansol Technics Co Ltd HS330ND-AN4: PTC thermal retention, roof footprint, and cold Voc string bounds.

Measured at 330.0 W STC and 302.6 W PTC, Hansol Technics Co Ltd HS330ND-AN4 sits -55.0 W vs all-CEC median (below all-CEC median; higher than 32.9% of peers) among 21,677 listed modules. Power density reaches 170.5 W/m2 (2.85 percentage points below 19.91% CEC median). Mid-range 46.9 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F, whereas 1,000 V commercial inverters handle up to 19 panels in series. Alternative peer Centrosolar America DM72 330 rates 330.0 W.

Where Does Hansol Technics Co Ltd HS330ND-AN4 Fall Across Listed CEC Models?

Distribution marker showing Hansol Technics Co Ltd HS330ND-AN4 (330.0 W) relative to the 385.0 W all-CEC solar panel median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Hansol Technics Co Ltd HS330ND-AN4 (330.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCHansol Technics Co: 330.0 W

What Dataset Percentiles Define Hansol Technics Co Ltd HS330ND-AN4?

Dataset percentiles tracking Hansol Technics Co Ltd HS330ND-AN4 power output, thermal retention ratio, and aperture efficiency against 21,677 models.

Hansol Technics Co Ltd HS330ND-AN4 Engineering BenchmarksPercentile comparison of Hansol Technics Co Ltd HS330ND-AN4 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage330.0 WPTC/STC Retention91.7%Module Efficiency17.06%

What Do the Dataset Ranks Show for Hansol Technics Co Ltd HS330ND-AN4?

Benchmark highlights for Hansol Technics Co Ltd HS330ND-AN4 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #14,165 / 21,677

330.0 W STC · Higher Than 32.9%

330.0 W STC (-55.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #16,397

17.06% Aperture Efficiency

Power density 170.5 W/m2 (2.85 percentage points below 19.91% CEC median). PTC/STC ratio: 91.7% (rank #15,053).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 51.94 V at -10 C (571.3 V string) and 53.38 V at -20 C (11 max).

8 kW Reference Array

25 Panels = 8,250 W STC

Occupies 48.4 m2 (521 sq ft) producing 7,565 W PTC; NEC 690.8 OCPD floor is 14.41 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 46.9 * (1 + (-0.307/100) * (-10 - 25)) = 51.94 V | OCPD = 1.56 * 9.24 = 14.41 A

Inputs from CEC Modules.csv for Hansol Technics Co Ltd HS330ND-AN4: Voc=46.9 V, beta_Voc=-0.307%/C, Isc=9.24 A, STC=330.0 W, Area=1.935 m2.

Result: 11 panels max on 600 V (571.3 V); 25 panels for 8 kW (521 sq ft).

What Are the Published CEC Specifications for Hansol Technics Co Ltd HS330ND-AN4?

Official CEC datasheet figures for Hansol Technics Co Ltd HS330ND-AN4 (Multi-c-Si) used in utility interconnection and permit reviews.

Official California Energy Commission (NREL SAM) test parameters for Hansol Technics Co Ltd HS330ND-AN4.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 330.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 302.6 W (91.7% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 46.9 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.24 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 37.9 V / 8.71 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.307 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 17.06% (1.935 m2) Array roof footprint density
Cell Count & Technology 72 cells (Multi-c-Si) Monofacial backsheet

How Many Hansol Technics Co Ltd HS330ND-AN4 Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many Hansol Technics Co Ltd HS330ND-AN4 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 19 6.27 kW 396 sq ft $1,569 $2,654
8 kW Class 25 8.25 kW 521 sq ft $2,065 $3,492
10 kW Class 31 10.23 kW 646 sq ft $2,560 $4,330

Which Sibling Wattage & Trim Variants Belong to This Hansol Technics Co Ltd Series?

Consolidated Hansol Technics Co Ltd wattage variants sharing the Hansol Technics Co Ltd HS330ND-AN4 mechanical and cell layout.

Sibling CEC listings grouped into the Hansol Technics Co Ltd HS330ND-AN4 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Hansol Technics Co Ltd HS325ND-AN4 325.0 W 297.9 W 46.5 V 37.5 V 16.8%
Hansol Technics Co Ltd HS330ND-AN4 330.0 W 302.6 W 46.9 V 37.9 V 17.06%
Hansol Technics Co Ltd HS335ND-AN4 335.0 W 307.3 W 47.3 V 38.3 V 17.32%

How Many Hansol Technics Co Ltd HS330ND-AN4 Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on Hansol Technics Co Ltd HS330ND-AN4 (51.94 V at 14 F).

Computed from Voc=46.9V and beta_Voc=-0.307%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 53.38 V 11 panels 587.2 V 18 panels
-10 C (14 F) 51.94 V 11 panels 571.3 V 19 panels
0 C (32 F) 50.5 V 11 panels 555.5 V 19 panels
25 C (77 F STC) 46.9 V 12 panels 562.8 V 21 panels

Which Cross-Brand Solar Modules Compare Closest to Hansol Technics Co Ltd HS330ND-AN4?

Competing CEC solar panels closest to Hansol Technics Co Ltd HS330ND-AN4 in nameplate wattage and Voc, starting with Centrosolar America DM72 330.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Centrosolar America DM72 330
Centrosolar America
330.0 W Tie (0 W) 46.9 V 16.97% 90.9%
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6P-330W
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd
330.0 W Tie (0 W) 46.65 V 17.16% 91.3%
Centrosolar America EP72 330BW
Centrosolar America
330.0 W Tie (0 W) 46.65 V 17.16% 91.3%
Centrosolar America EP72 330SW
Centrosolar America
330.0 W Tie (0 W) 46.65 V 17.16% 91.3%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Hansol Technics Co Ltd HS330ND-AN4?

Evaluate Hansol Technics Co Ltd HS330ND-AN4 (330.0 W STC, 46.9 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Hansol Technics Co Ltd HS330ND-AN4 reaches 53.38 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 25 panels for an 8 kW build require 521 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 25 panels (521 sq ft).
  • 2026 tax credit baseline: cash residential installs of Hansol Technics Co Ltd HS330ND-AN4 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Hansol Technics Co Ltd HS330ND-AN4 8 kW Residential Fit

Needs 25 modules (521 sq ft) with a 15 A string OCPD, offsetting ~$2,065/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Centrosolar America DM72 330.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 302.6 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Hansol Technics Co Ltd HS330ND-AN4 by Hansol Technics Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.

How many Hansol Technics Co Ltd HS330ND-AN4 panels fit on a 600 V winter solar string?

At -10 C (14 F), Hansol Technics Co Ltd HS330ND-AN4 cold Voc rises from 46.9 V to 51.94 V (beta_Voc -0.307%/C), capping a 600 V string at 11 panels (571.3 V).

How much roof area does an 8 kW array of Hansol Technics Co Ltd HS330ND-AN4 need?

An 8 kW DC system uses 25 Hansol Technics Co Ltd HS330ND-AN4 modules (8,250 W STC / 7,565 W PTC), covering roughly 521 sq ft and saving ~$2,065/yr at 18.54 c/kWh.

How does Hansol Technics Co Ltd HS330ND-AN4 compare against Centrosolar America DM72 330?

Hansol Technics Co Ltd HS330ND-AN4 outputs 330.0 W STC (46.9 V Voc, rank #14,165 of 21,677), while Centrosolar America DM72 330 delivers 330.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.