Hansol Technics Co Ltd HS310ND-AN3 is a 310.0 W STC (279.8 W PTC) Multi-c-Si solar module ranking #15,760 of 21,677 CEC listings (below all-CEC median; higher than 25.6% of peers). It delivers 15.55% efficiency, 45.3 V Voc at 25 C, and 50.22 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 310.0 W
- PTC Wattage
- 279.8 W
- Voc @ 25C
- 45.3 V
- Efficiency
- 15.55%
How Does Hansol Technics Co Ltd HS310ND-AN3 Compare Against Peer CEC Listings?
Engineering position of Hansol Technics Co Ltd HS310ND-AN3 (310.0 W STC) vs. Advance Power API-P310 across 1,407 CEC Multi-c-Si solar modules.
Ranking #15,760 across 21,677 CEC solar panels (below all-CEC median; higher than 25.6% of peers), Hansol Technics Co Ltd HS310ND-AN3 operates as a compact residential or specialty off-grid module sitting 31.2 W above the 278.8 W Multi-c-Si median. Mid-range 45.3 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F. With typical 90.3% PTC-to-STC thermal output (279.8 W real-world rating), 26 panels occupy 558 sq ft and offset roughly $2,017/yr at average US rates (or $3,411/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.
Where Does Hansol Technics Co Ltd HS310ND-AN3 Fall Across Listed CEC Models?
Plots Hansol Technics Co Ltd HS310ND-AN3 at 310.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.
What Dataset Percentiles Define Hansol Technics Co Ltd HS310ND-AN3?
Benchmarks Hansol Technics Co Ltd HS310ND-AN3 on STC wattage, thermal PTC/STC retention, and 15.55 aperture conversion efficiency against CEC peers.
What Do the Dataset Ranks Show for Hansol Technics Co Ltd HS310ND-AN3?
Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Hansol Technics Co Ltd HS310ND-AN3 by Hansol Technics Co Ltd.
310.0 W STC · Higher Than 25.6%
310.0 W STC (-75.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.
15.55% Aperture Efficiency
Power density 155.5 W/m2 (4.36 percentage points below 19.91% CEC median). PTC/STC ratio: 90.3% (rank #18,305).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 50.22 V at -10 C (552.4 V string) and 51.62 V at -20 C (11 max).
26 Panels = 8,060 W STC
Occupies 51.8 m2 (558 sq ft) producing 7,275 W PTC; NEC 690.8 OCPD floor is 14.15 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 45.3 * (1 + (-0.31/100) * (-10 - 25)) = 50.22 V | OCPD = 1.56 * 9.07 = 14.15 A
Inputs from CEC Modules.csv for Hansol Technics Co Ltd HS310ND-AN3: Voc=45.3 V, beta_Voc=-0.31%/C, Isc=9.07 A, STC=310.0 W, Area=1.994 m2.
Result: 11 panels max on 600 V (552.4 V); 26 panels for 8 kW (558 sq ft).
What Are the Published CEC Specifications for Hansol Technics Co Ltd HS310ND-AN3?
Laboratory test ratings recorded for Hansol Technics Co Ltd HS310ND-AN3 (Multi-c-Si) in the official California Energy Commission NREL SAM equipment catalog.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 310.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 279.8 W (90.3% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 45.3 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.07 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 36.3 V / 8.55 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.31 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 15.55% (1.994 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Multi-c-Si) | Monofacial backsheet |
How Many Hansol Technics Co Ltd HS310ND-AN3 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Panel counts, roof square footage (558 sq ft at 8 kW), and estimated Year-1 electric bill offset for Hansol Technics Co Ltd HS310ND-AN3.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 20 | 6.2 kW | 429 sq ft | $1,552 | $2,624 |
| 8 kW Class | 26 | 8.06 kW | 558 sq ft | $2,017 | $3,411 |
| 10 kW Class | 33 | 10.23 kW | 708 sq ft | $2,560 | $4,330 |
Which Sibling Wattage & Trim Variants Belong to This Hansol Technics Co Ltd Series?
Sibling wattage bins and frame colors grouped with Hansol Technics Co Ltd HS310ND-AN3 under Hansol Technics Co Ltd to prevent duplicate spec pages.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Hansol Technics Co Ltd HS300ND-AN3 | 300.0 W | 270.5 W | 44.5 V | 35.5 V | 15.05% |
| Hansol Technics Co Ltd HS305ND-AN3 | 305.0 W | 275.1 W | 44.9 V | 35.9 V | 15.3% |
| Hansol Technics Co Ltd HS310ND-AN3 | 310.0 W | 279.8 W | 45.3 V | 36.3 V | 15.55% |
| Hansol Technics Co Ltd HS315ND-AN3 | 315.0 W | 284.4 W | 45.7 V | 36.7 V | 15.8% |
| Hansol Technics Co Ltd HS320ND-AN3 | 320.0 W | 289.0 W | 46.1 V | 37.1 V | 16.05% |
How Many Hansol Technics Co Ltd HS310ND-AN3 Modules Fit in a Cold-Weather String?
Cold-weather Voc escalation for Hansol Technics Co Ltd HS310ND-AN3 (beta_Voc -0.31%/C) across 600 V residential and 1,000 V commercial inverters.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 51.62 V | 11 panels | 567.8 V | 19 panels |
| -10 C (14 F) | 50.22 V | 11 panels | 552.4 V | 19 panels |
| 0 C (32 F) | 48.81 V | 12 panels | 585.7 V | 20 panels |
| 25 C (77 F STC) | 45.3 V | 13 panels | 588.9 V | 22 panels |
Which Cross-Brand Solar Modules Compare Closest to Hansol Technics Co Ltd HS310ND-AN3?
Closest cross-brand CEC competitors to Hansol Technics Co Ltd HS310ND-AN3 matched near 310.0 W STC and 45.3 V Voc, led by Advance Power API-P310.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Advance Power API-P310 Advance Power |
310.0 W | Tie (0 W) | 45.22 V | 15.89% | 89.5% |
| Auxin Solar AXN6P612T310 Auxin Solar |
310.0 W | Tie (0 W) | 45.22 V | 15.89% | 89.5% |
| Chinaland Solar Energy HSE310-72M Chinaland Solar Energy |
310.0 W | Tie (0 W) | 45.4 V | 16.06% | 90.3% |
| GCL System Integration Technology Co Ltd GCL-P6/72310 GCL System Integration Technology Co Ltd |
310.0 W | Tie (0 W) | 45.4 V | 15.98% | 90.5% |
What Are the Design Limits and Best-Fit Uses for Hansol Technics Co Ltd HS310ND-AN3?
Evaluate Hansol Technics Co Ltd HS310ND-AN3 (310.0 W STC, 45.3 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Hansol Technics Co Ltd HS310ND-AN3 reaches 51.62 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 26 panels for an 8 kW build require 558 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 26 panels (558 sq ft).
- 2026 tax credit baseline: cash residential installs of Hansol Technics Co Ltd HS310ND-AN3 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Hansol Technics Co Ltd HS310ND-AN3 8 kW Residential Fit
Needs 26 modules (558 sq ft) with a 15 A string OCPD, offsetting ~$2,017/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Advance Power API-P310.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 279.8 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Hansol Technics Co Ltd HS310ND-AN3 by Hansol Technics Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
How many Hansol Technics Co Ltd HS310ND-AN3 panels fit on a 600 V winter solar string?
At -10 C (14 F), Hansol Technics Co Ltd HS310ND-AN3 cold Voc rises from 45.3 V to 50.22 V (beta_Voc -0.31%/C), capping a 600 V string at 11 panels (552.4 V).
How much roof area does an 8 kW array of Hansol Technics Co Ltd HS310ND-AN3 need?
An 8 kW DC system uses 26 Hansol Technics Co Ltd HS310ND-AN3 modules (8,060 W STC / 7,275 W PTC), covering roughly 558 sq ft and saving ~$2,017/yr at 18.54 c/kWh.
How does Hansol Technics Co Ltd HS310ND-AN3 compare against Advance Power API-P310?
Hansol Technics Co Ltd HS310ND-AN3 outputs 310.0 W STC (45.3 V Voc, rank #15,760 of 21,677), while Advance Power API-P310 delivers 310.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)