Hansol Technics Co Ltd HS300TB-AN3 is a 300.0 W STC (269.5 W PTC) Multi-c-Si solar module ranking #16,498 of 21,677 CEC listings (below all-CEC median; higher than 22.1% of peers). It delivers 17.96% efficiency, 40.3 V Voc at 25 C, and 45.1 V cold Voc at -10 C (13 panels max per 600 V string).
- STC Wattage
- 300.0 W
- PTC Wattage
- 269.5 W
- Voc @ 25C
- 40.3 V
- Efficiency
- 17.96%
How Does Hansol Technics Co Ltd HS300TB-AN3 Compare Against Peer CEC Listings?
Solar engineering breakdown for Hansol Technics Co Ltd HS300TB-AN3: PTC thermal retention, roof footprint, and cold Voc string bounds.
Measured at 300.0 W STC and 269.5 W PTC, Hansol Technics Co Ltd HS300TB-AN3 sits -85.0 W vs all-CEC median (below all-CEC median; higher than 22.1% of peers) among 21,677 listed modules. Power density reaches 179.6 W/m2 (1.95 percentage points below 19.91% CEC median). Mid-range 40.3 V open-circuit voltage allows up to 13 panels per 600 V string at 14 F, whereas 1,000 V commercial inverters handle up to 22 panels in series. Alternative peer CertainTeed CT300M10-03 rates 300.0 W.
Where Does Hansol Technics Co Ltd HS300TB-AN3 Fall Across Listed CEC Models?
Distribution marker showing Hansol Technics Co Ltd HS300TB-AN3 (300.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define Hansol Technics Co Ltd HS300TB-AN3?
Dataset percentiles tracking Hansol Technics Co Ltd HS300TB-AN3 power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for Hansol Technics Co Ltd HS300TB-AN3?
Benchmark highlights for Hansol Technics Co Ltd HS300TB-AN3 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
300.0 W STC · Higher Than 22.1%
300.0 W STC (-85.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.
17.96% Aperture Efficiency
Power density 179.6 W/m2 (1.95 percentage points below 19.91% CEC median). PTC/STC ratio: 89.8% (rank #19,481).
13 Panels Max @ -10 C (600 V)
Cold Voc reaches 45.1 V at -10 C (586.3 V string) and 46.47 V at -20 C (12 max).
27 Panels = 8,100 W STC
Occupies 45.1 m2 (485 sq ft) producing 7,276 W PTC; NEC 690.8 OCPD floor is 15.04 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 40.3 * (1 + (-0.34/100) * (-10 - 25)) = 45.1 V | OCPD = 1.56 * 9.64 = 15.04 A
Inputs from CEC Modules.csv for Hansol Technics Co Ltd HS300TB-AN3: Voc=40.3 V, beta_Voc=-0.34%/C, Isc=9.64 A, STC=300.0 W, Area=1.67 m2.
Result: 13 panels max on 600 V (586.3 V); 27 panels for 8 kW (485 sq ft).
What Are the Published CEC Specifications for Hansol Technics Co Ltd HS300TB-AN3?
Official CEC datasheet figures for Hansol Technics Co Ltd HS300TB-AN3 (Multi-c-Si) used in utility interconnection and permit reviews.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 300.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 269.5 W (89.8% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 40.3 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.64 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 33.0 V / 9.1 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.34 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 17.96% (1.67 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Multi-c-Si) | Monofacial backsheet |
How Many Hansol Technics Co Ltd HS300TB-AN3 Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many Hansol Technics Co Ltd HS300TB-AN3 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 20 | 6.0 kW | 360 sq ft | $1,502 | $2,539 |
| 8 kW Class | 27 | 8.1 kW | 485 sq ft | $2,027 | $3,428 |
| 10 kW Class | 34 | 10.2 kW | 611 sq ft | $2,553 | $4,317 |
How Many Hansol Technics Co Ltd HS300TB-AN3 Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on Hansol Technics Co Ltd HS300TB-AN3 (45.1 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 46.47 V | 12 panels | 557.6 V | 21 panels |
| -10 C (14 F) | 45.1 V | 13 panels | 586.3 V | 22 panels |
| 0 C (32 F) | 43.73 V | 13 panels | 568.5 V | 22 panels |
| 25 C (77 F STC) | 40.3 V | 14 panels | 564.2 V | 24 panels |
Which Cross-Brand Solar Modules Compare Closest to Hansol Technics Co Ltd HS300TB-AN3?
Competing CEC solar panels closest to Hansol Technics Co Ltd HS300TB-AN3 in nameplate wattage and Voc, starting with CertainTeed CT300M10-03.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| CertainTeed CT300M10-03 CertainTeed |
300.0 W | Tie (0 W) | 40.3 V | 18.55% | 92.4% |
| CertainTeed CT300M11-03 CertainTeed |
300.0 W | Tie (0 W) | 40.3 V | 18.68% | 92.1% |
| Enphase Energy Inc XACM-IQ7-LR6-60PB-300M Enphase Energy Inc |
300.0 W | Tie (0 W) | 40.1 V | 18.99% | 91.1% |
| FreeVolt PV-GRAF-60M6-300/M FreeVolt |
300.0 W | Tie (0 W) | 39.6 V | 18.29% | 91.1% |
What Are the Design Limits and Best-Fit Uses for Hansol Technics Co Ltd HS300TB-AN3?
Evaluate Hansol Technics Co Ltd HS300TB-AN3 (300.0 W STC, 40.3 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Hansol Technics Co Ltd HS300TB-AN3 reaches 46.47 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
- Footprint constraint: 27 panels for an 8 kW build require 485 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 27 panels (485 sq ft).
- 2026 tax credit baseline: cash residential installs of Hansol Technics Co Ltd HS300TB-AN3 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Hansol Technics Co Ltd HS300TB-AN3 8 kW Residential Fit
Needs 27 modules (485 sq ft) with a 20 A string OCPD, offsetting ~$2,027/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 13 panels (-10 C) or 12 panels (-20 C), or compare CertainTeed CT300M10-03.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 269.5 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Hansol Technics Co Ltd HS300TB-AN3 by Hansol Technics Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
How many Hansol Technics Co Ltd HS300TB-AN3 panels fit on a 600 V winter solar string?
At -10 C (14 F), Hansol Technics Co Ltd HS300TB-AN3 cold Voc rises from 40.3 V to 45.1 V (beta_Voc -0.34%/C), capping a 600 V string at 13 panels (586.3 V).
How much roof area does an 8 kW array of Hansol Technics Co Ltd HS300TB-AN3 need?
An 8 kW DC system uses 27 Hansol Technics Co Ltd HS300TB-AN3 modules (8,100 W STC / 7,276 W PTC), covering roughly 485 sq ft and saving ~$2,027/yr at 18.54 c/kWh.
How does Hansol Technics Co Ltd HS300TB-AN3 compare against CertainTeed CT300M10-03?
Hansol Technics Co Ltd HS300TB-AN3 outputs 300.0 W STC (40.3 V Voc, rank #16,498 of 21,677), while CertainTeed CT300M10-03 delivers 300.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)