Hansol Technics Co Ltd HS295UB-JH2 {Blk} is a 295.0 W STC (274.0 W PTC) Mono-c-Si solar module ranking #16,890 of 21,677 CEC listings (below all-CEC median; higher than 20.4% of peers). It delivers 18.31% efficiency, 39.6 V Voc at 25 C, and 43.48 V cold Voc at -10 C (13 panels max per 600 V string).
- STC Wattage
- 295.0 W
- PTC Wattage
- 274.0 W
- Voc @ 25C
- 39.6 V
- Efficiency
- 18.31%
How Does Hansol Technics Co Ltd HS295UB-JH2 {Blk} Compare Against Peer CEC Listings?
How Hansol Technics Co Ltd Hansol Technics Co Ltd HS295UB-JH2 {Blk} handles rooftop heat (274.0 W PTC), 8 kW sizing, and cold winter string voltage.
Hansol Technics Co Ltd builds the Hansol Technics Co Ltd HS295UB-JH2 {Blk} (Mono-c-Si) as a compact residential or specialty off-grid module delivering 183.1 W/m2 (1.60 percentage points below 19.91% CEC median). Compared against GCL System Integration Technology Co Ltd GCL-M6/60295 (295.0 W), this model holds strong 92.9% PTC-to-STC heat retention (#10,348 of 21,677). Lower 39.6 V string voltage fits 13 panels in series at 14 F and pairs easily with microinverters, while NEC 690.8 sets a 14.73 A overcurrent floor served by a 15 A breaker.
Where Does Hansol Technics Co Ltd HS295UB-JH2 {Blk} Fall Across Listed CEC Models?
Where Hansol Technics Co Ltd HS295UB-JH2 {Blk} (295.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define Hansol Technics Co Ltd HS295UB-JH2 {Blk}?
Percentile placement of Hansol Technics Co Ltd HS295UB-JH2 {Blk} across power density (183.1 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for Hansol Technics Co Ltd HS295UB-JH2 {Blk}?
Four critical engineering numbers homeowners and solar installers check first when reviewing Hansol Technics Co Ltd HS295UB-JH2 {Blk} specifications.
295.0 W STC · Higher Than 20.4%
295.0 W STC (-90.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
18.31% Aperture Efficiency
Power density 183.1 W/m2 (1.60 percentage points below 19.91% CEC median). PTC/STC ratio: 92.9% (rank #10,348).
13 Panels Max @ -10 C (600 V)
Cold Voc reaches 43.48 V at -10 C (565.2 V string) and 44.59 V at -20 C (13 max).
28 Panels = 8,260 W STC
Occupies 45.1 m2 (486 sq ft) producing 7,672 W PTC; NEC 690.8 OCPD floor is 14.73 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 39.6 * (1 + (-0.28/100) * (-10 - 25)) = 43.48 V | OCPD = 1.56 * 9.44 = 14.73 A
Inputs from CEC Modules.csv for Hansol Technics Co Ltd HS295UB-JH2 {Blk}: Voc=39.6 V, beta_Voc=-0.28%/C, Isc=9.44 A, STC=295.0 W, Area=1.611 m2.
Result: 13 panels max on 600 V (565.2 V); 28 panels for 8 kW (486 sq ft).
What Are the Published CEC Specifications for Hansol Technics Co Ltd HS295UB-JH2 {Blk}?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Hansol Technics Co Ltd HS295UB-JH2 {Blk}.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 295.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 274.0 W (92.9% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 39.6 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.44 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 33.5 V / 8.81 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.28 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 18.31% (1.611 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Mono-c-Si) | Monofacial backsheet |
How Many Hansol Technics Co Ltd HS295UB-JH2 {Blk} Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Hansol Technics Co Ltd HS295UB-JH2 {Blk} (295.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 21 | 6.2 kW | 364 sq ft | $1,552 | $2,624 |
| 8 kW Class | 28 | 8.26 kW | 486 sq ft | $2,067 | $3,496 |
| 10 kW Class | 34 | 10.03 kW | 590 sq ft | $2,510 | $4,245 |
How Many Hansol Technics Co Ltd HS295UB-JH2 {Blk} Modules Fit in a Cold-Weather String?
Maximum series module counts for Hansol Technics Co Ltd HS295UB-JH2 {Blk} from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 44.59 V | 13 panels | 579.7 V | 22 panels |
| -10 C (14 F) | 43.48 V | 13 panels | 565.2 V | 22 panels |
| 0 C (32 F) | 42.37 V | 14 panels | 593.2 V | 23 panels |
| 25 C (77 F STC) | 39.6 V | 15 panels | 594.0 V | 25 panels |
Which Cross-Brand Solar Modules Compare Closest to Hansol Technics Co Ltd HS295UB-JH2 {Blk}?
Alternative CEC solar modules from competing brands near Hansol Technics Co Ltd HS295UB-JH2 {Blk} (295.0 W), including GCL System Integration Technology Co Ltd GCL-M6/60295.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| GCL System Integration Technology Co Ltd GCL-M6/60295 GCL System Integration Technology Co Ltd |
295.0 W | Tie (0 W) | 39.3 V | 18.1% | 90.2% |
| CSI Solar Co Ltd CS3K-295MS CSI Solar Co Ltd |
295.0 W | Tie (0 W) | 39.1 V | 18.4% | 93.0% |
| DualSun SAS DualSun 290M-60-00 DualSun SAS |
290.0 W | -5.0 W | 39.7 V | 17.68% | 90.9% |
| CertainTeed CT290M10-02 CertainTeed |
290.0 W | -5.0 W | 39.77 V | 17.83% | 91.8% |
What Are the Design Limits and Best-Fit Uses for Hansol Technics Co Ltd HS295UB-JH2 {Blk}?
Evaluate Hansol Technics Co Ltd HS295UB-JH2 {Blk} (295.0 W STC, 39.6 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Hansol Technics Co Ltd HS295UB-JH2 {Blk} reaches 44.59 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 28 panels for an 8 kW build require 486 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 28 panels (486 sq ft).
- 2026 tax credit baseline: cash residential installs of Hansol Technics Co Ltd HS295UB-JH2 {Blk} carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Hansol Technics Co Ltd HS295UB-JH2 {Blk} 8 kW Residential Fit
Needs 28 modules (486 sq ft) with a 15 A string OCPD, offsetting ~$2,067/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare GCL System Integration Technology Co Ltd GCL-M6/60295.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 274.0 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Hansol Technics Co Ltd HS295UB-JH2 {Blk} by Hansol Technics Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Hansol Technics Co Ltd HS295UB-JH2 {Blk}?
Multiplying Hansol Technics Co Ltd HS295UB-JH2 {Blk}'s 9.44 A short-circuit current by 1.56 equals 14.73 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.
Can Hansol Technics Co Ltd HS295UB-JH2 {Blk} pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 43.48 V cold Voc at 14 F and handles 9.44 A Isc; string inverters cap Hansol Technics Co Ltd HS295UB-JH2 {Blk} at 13 panels on 600 V.
Is Hansol Technics Co Ltd HS295UB-JH2 {Blk} eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Hansol Technics Co Ltd HS295UB-JH2 {Blk} rely on utility bill offset (~$2,067/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)