Skip to main content
WireAndSun
Calculators
CEC PV Module

Hanersun Energy Co Ltd HN21RN-48HT455W — CEC Solar Module Specifications

Manufacturer: Hanersun Energy Co Ltd Registry: CEC Verified Engineering Specification

Hanersun Energy Co Ltd HN21RN-48HT455W is a 455.0 W STC (432.8 W PTC) Mono-c-Si solar module ranking #5,417 of 21,677 CEC listings (top 26.2%; higher than 73.8% of peers). It delivers 23.45% efficiency, 35.93 V Voc at 25 C, and 39.38 V cold Voc at -10 C (15 panels max per 600 V string).

STC Wattage
455.0 W
PTC Wattage
432.8 W
Voc @ 25C
35.93 V
Efficiency
23.45%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Hanersun Energy Co Ltd HN21RN-48HT455W Compare Against Peer CEC Listings?

Solar engineering breakdown for Hanersun Energy Co Ltd HN21RN-48HT455W: PTC thermal retention, roof footprint, and cold Voc string bounds.

Measured at 455.0 W STC and 432.8 W PTC, Hanersun Energy Co Ltd HN21RN-48HT455W sits +70.0 W vs all-CEC median (top 26.2%; higher than 73.8% of peers) among 21,677 listed modules. Power density reaches 234.5 W/m2 (3.54 percentage points above 19.91% CEC median). Lower 35.93 V string voltage fits 15 panels in series at 14 F and pairs easily with microinverters, whereas 1,000 V commercial inverters handle up to 25 panels in series. Alternative peer CSI Solar Co Ltd CS62-48TM-455H rates 455.0 W.

Where Does Hanersun Energy Co Ltd HN21RN-48HT455W Fall Across Listed CEC Models?

Distribution marker showing Hanersun Energy Co Ltd HN21RN-48HT455W (455.0 W) relative to the 385.0 W all-CEC solar panel median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Hanersun Energy Co Ltd HN21RN-48HT455W (455.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCHanersun Energy Co: 455.0 W

What Dataset Percentiles Define Hanersun Energy Co Ltd HN21RN-48HT455W?

Dataset percentiles tracking Hanersun Energy Co Ltd HN21RN-48HT455W power output, thermal retention ratio, and aperture efficiency against 21,677 models.

Hanersun Energy Co Ltd HN21RN-48HT455W Engineering BenchmarksPercentile comparison of Hanersun Energy Co Ltd HN21RN-48HT455W wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage455.0 WPTC/STC Retention95.1%Module Efficiency23.45%

What Do the Dataset Ranks Show for Hanersun Energy Co Ltd HN21RN-48HT455W?

Benchmark highlights for Hanersun Energy Co Ltd HN21RN-48HT455W covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #5,417 / 21,677

Top 26.2% STC Output

455.0 W STC (+70.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #560

23.45% Aperture Efficiency

Power density 234.5 W/m2 (3.54 percentage points above 19.91% CEC median). PTC/STC ratio: 95.1% (rank #713).

NEC 690.7 Limit

15 Panels Max @ -10 C (600 V)

Cold Voc reaches 39.38 V at -10 C (590.7 V string) and 40.36 V at -20 C (14 max).

8 kW Reference Array

18 Panels = 8,190 W STC

Occupies 34.9 m2 (376 sq ft) producing 7,790 W PTC; NEC 690.8 OCPD floor is 25.05 A (30 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 35.93 * (1 + (-0.274/100) * (-10 - 25)) = 39.38 V | OCPD = 1.56 * 16.06 = 25.05 A

Inputs from CEC Modules.csv for Hanersun Energy Co Ltd HN21RN-48HT455W: Voc=35.93 V, beta_Voc=-0.274%/C, Isc=16.06 A, STC=455.0 W, Area=1.94 m2.

Result: 15 panels max on 600 V (590.7 V); 18 panels for 8 kW (376 sq ft).

What Are the Published CEC Specifications for Hanersun Energy Co Ltd HN21RN-48HT455W?

Official CEC datasheet figures for Hanersun Energy Co Ltd HN21RN-48HT455W (Mono-c-Si) used in utility interconnection and permit reviews.

Official California Energy Commission (NREL SAM) test parameters for Hanersun Energy Co Ltd HN21RN-48HT455W.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 455.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 432.8 W (95.1% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 35.93 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 16.06 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 29.94 V / 15.2 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.274 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 23.45% (1.94 m2) Array roof footprint density
Cell Count & Technology 48 cells (Mono-c-Si) Monofacial backsheet

How Many Hanersun Energy Co Ltd HN21RN-48HT455W Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many Hanersun Energy Co Ltd HN21RN-48HT455W modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 14 6.37 kW 292 sq ft $1,594 $2,696
8 kW Class 18 8.19 kW 376 sq ft $2,050 $3,466
10 kW Class 22 10.01 kW 459 sq ft $2,505 $4,236

Which Sibling Wattage & Trim Variants Belong to This Hanersun Energy Co Ltd Series?

Consolidated Hanersun Energy Co Ltd wattage variants sharing the Hanersun Energy Co Ltd HN21RN-48HT455W mechanical and cell layout.

Sibling CEC listings grouped into the Hanersun Energy Co Ltd HN21RN-48HT455W wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Hanersun Energy Co Ltd HN21RN-48HT450W 450.0 W 427.9 W 35.73 V 29.78 V 23.2%
Hanersun Energy Co Ltd HN21RN-48HT455W 455.0 W 432.8 W 35.93 V 29.94 V 23.45%

How Many Hanersun Energy Co Ltd HN21RN-48HT455W Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on Hanersun Energy Co Ltd HN21RN-48HT455W (39.38 V at 14 F).

Computed from Voc=35.93V and beta_Voc=-0.274%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 40.36 V 14 panels 565.0 V 24 panels
-10 C (14 F) 39.38 V 15 panels 590.7 V 25 panels
0 C (32 F) 38.39 V 15 panels 575.9 V 26 panels
25 C (77 F STC) 35.93 V 16 panels 574.9 V 27 panels

Which Cross-Brand Solar Modules Compare Closest to Hanersun Energy Co Ltd HN21RN-48HT455W?

Competing CEC solar panels closest to Hanersun Energy Co Ltd HN21RN-48HT455W in nameplate wattage and Voc, starting with CSI Solar Co Ltd CS62-48TM-455H.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
CSI Solar Co Ltd CS62-48TM-455H
CSI Solar Co Ltd
455.0 W Tie (0 W) 36.0 V 23.58% 95.0%
G-Star Pte Ltd GSD8R48T-460BT
G-Star Pte Ltd
460.0 W +5.0 W 35.99 V 23.23% 95.2%
G-Star Pte Ltd GSD8R48T-460WT
G-Star Pte Ltd
460.0 W +5.0 W 35.99 V 23.23% 95.2%
ELITE Solar ET-NR48TBH460GB
ELITE Solar
460.0 W +5.0 W 36.09 V 23.0% 95.1%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Hanersun Energy Co Ltd HN21RN-48HT455W?

Evaluate Hanersun Energy Co Ltd HN21RN-48HT455W (455.0 W STC, 35.93 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Hanersun Energy Co Ltd HN21RN-48HT455W reaches 40.36 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 18 panels for an 8 kW build require 376 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 18 panels (376 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of Hanersun Energy Co Ltd HN21RN-48HT455W carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Hanersun Energy Co Ltd HN21RN-48HT455W 8 kW Residential Fit

Needs 18 modules (376 sq ft) with a 30 A string OCPD, offsetting ~$2,050/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 15 panels (-10 C) or 14 panels (-20 C), or compare CSI Solar Co Ltd CS62-48TM-455H.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 432.8 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Hanersun Energy Co Ltd HN21RN-48HT455W by Hanersun Energy Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.

How many Hanersun Energy Co Ltd HN21RN-48HT455W panels fit on a 600 V winter solar string?

At -10 C (14 F), Hanersun Energy Co Ltd HN21RN-48HT455W cold Voc rises from 35.93 V to 39.38 V (beta_Voc -0.274%/C), capping a 600 V string at 15 panels (590.7 V).

How much roof area does an 8 kW array of Hanersun Energy Co Ltd HN21RN-48HT455W need?

An 8 kW DC system uses 18 Hanersun Energy Co Ltd HN21RN-48HT455W modules (8,190 W STC / 7,790 W PTC), covering roughly 376 sq ft and saving ~$2,050/yr at 18.54 c/kWh.

How does Hanersun Energy Co Ltd HN21RN-48HT455W compare against CSI Solar Co Ltd CS62-48TM-455H?

Hanersun Energy Co Ltd HN21RN-48HT455W outputs 455.0 W STC (35.93 V Voc, rank #5,417 of 21,677), while CSI Solar Co Ltd CS62-48TM-455H delivers 455.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.