CSI Solar Co Ltd CS62-48TM-455H is a 455.0 W STC (432.3 W PTC) Mono-c-Si solar module ranking #5,417 of 21,677 CEC listings (top 26.2%; higher than 73.8% of peers). It delivers 23.58% efficiency, 36.0 V Voc at 25 C, and 37.84 V cold Voc at -10 C (15 panels max per 600 V string).
- STC Wattage
- 455.0 W
- PTC Wattage
- 432.3 W
- Voc @ 25C
- 36.0 V
- Efficiency
- 23.58%
How Does CSI Solar Co Ltd CS62-48TM-455H Compare Against Peer CEC Listings?
How CSI Solar Co Ltd CSI Solar Co Ltd CS62-48TM-455H handles rooftop heat (432.3 W PTC), 8 kW sizing, and cold winter string voltage.
For NEC string engineering, CSI Solar Co Ltd CS62-48TM-455H exhibits 15.89 A short-circuit current, requiring a 24.79 A (156%) conductor rating and 25 A OCPD under NEC 690.8. Ranked #5,417 of 21,677 (45.0 W above the 410.0 W Mono-c-Si median), this modern high-density residential and light-commercial module covers 34.7 m2 for an 8 kW system (22 panels for 10 kW). Lower 36.0 V string voltage fits 15 panels in series at 14 F and pairs easily with microinverters.
Where Does CSI Solar Co Ltd CS62-48TM-455H Fall Across Listed CEC Models?
Where CSI Solar Co Ltd CS62-48TM-455H (455.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define CSI Solar Co Ltd CS62-48TM-455H?
Percentile placement of CSI Solar Co Ltd CS62-48TM-455H across power density (235.8 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for CSI Solar Co Ltd CS62-48TM-455H?
Four critical engineering numbers homeowners and solar installers check first when reviewing CSI Solar Co Ltd CS62-48TM-455H specifications.
Top 26.2% STC Output
455.0 W STC (+70.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
23.58% Aperture Efficiency
Power density 235.8 W/m2 (3.67 percentage points above 19.91% CEC median). PTC/STC ratio: 95.0% (rank #1,106).
15 Panels Max @ -10 C (600 V)
Cold Voc reaches 37.84 V at -10 C (567.6 V string) and 38.37 V at -20 C (15 max).
18 Panels = 8,190 W STC
Occupies 34.7 m2 (374 sq ft) producing 7,781 W PTC; NEC 690.8 OCPD floor is 24.79 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 36.0 * (1 + (-0.146/100) * (-10 - 25)) = 37.84 V | OCPD = 1.56 * 15.89 = 24.79 A
Inputs from CEC Modules.csv for CSI Solar Co Ltd CS62-48TM-455H: Voc=36.0 V, beta_Voc=-0.146%/C, Isc=15.89 A, STC=455.0 W, Area=1.93 m2.
Result: 15 panels max on 600 V (567.6 V); 18 panels for 8 kW (374 sq ft).
What Are the Published CEC Specifications for CSI Solar Co Ltd CS62-48TM-455H?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for CSI Solar Co Ltd CS62-48TM-455H.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 455.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 432.3 W (95.0% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 36.0 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 15.89 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 30.8 V / 14.78 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.146 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 23.58% (1.93 m2) | Array roof footprint density |
| Cell Count & Technology | 48 cells (Mono-c-Si) | Monofacial backsheet |
How Many CSI Solar Co Ltd CS62-48TM-455H Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using CSI Solar Co Ltd CS62-48TM-455H (455.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 14 | 6.37 kW | 291 sq ft | $1,594 | $2,696 |
| 8 kW Class | 18 | 8.19 kW | 374 sq ft | $2,050 | $3,466 |
| 10 kW Class | 22 | 10.01 kW | 457 sq ft | $2,505 | $4,236 |
Which Sibling Wattage & Trim Variants Belong to This CSI Solar Co Ltd Series?
All closely matched CSI Solar Co Ltd wattages and cosmetic trims sharing the CSI Solar Co Ltd CS62-48TM-455H architecture.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| CSI Solar Co Ltd CS62-48TM-450H | 450.0 W | 427.4 W | 35.8 V | 30.6 V | 23.32% |
| CSI Solar Co Ltd CS62-48TM-455H | 455.0 W | 432.3 W | 36.0 V | 30.8 V | 23.58% |
| CSI Solar Co Ltd CS62-48TM-460H | 460.0 W | 437.1 W | 36.2 V | 31.0 V | 23.83% |
How Many CSI Solar Co Ltd CS62-48TM-455H Modules Fit in a Cold-Weather String?
Maximum series module counts for CSI Solar Co Ltd CS62-48TM-455H from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 38.37 V | 15 panels | 575.5 V | 26 panels |
| -10 C (14 F) | 37.84 V | 15 panels | 567.6 V | 26 panels |
| 0 C (32 F) | 37.31 V | 16 panels | 597.0 V | 26 panels |
| 25 C (77 F STC) | 36.0 V | 16 panels | 576.0 V | 27 panels |
Which Cross-Brand Solar Modules Compare Closest to CSI Solar Co Ltd CS62-48TM-455H?
Alternative CEC solar modules from competing brands near CSI Solar Co Ltd CS62-48TM-455H (455.0 W), including Hanersun Energy Co Ltd HN21RN-48HT455W.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Hanersun Energy Co Ltd HN21RN-48HT455W Hanersun Energy Co Ltd |
455.0 W | Tie (0 W) | 35.93 V | 23.45% | 95.1% |
| G-Star Pte Ltd GSD8R48T-460BT G-Star Pte Ltd |
460.0 W | +5.0 W | 35.99 V | 23.23% | 95.2% |
| G-Star Pte Ltd GSD8R48T-460WT G-Star Pte Ltd |
460.0 W | +5.0 W | 35.99 V | 23.23% | 95.2% |
| ELITE Solar ET-NR48TBH460GB ELITE Solar |
460.0 W | +5.0 W | 36.09 V | 23.0% | 95.1% |
What Are the Design Limits and Best-Fit Uses for CSI Solar Co Ltd CS62-48TM-455H?
Evaluate CSI Solar Co Ltd CS62-48TM-455H (455.0 W STC, 36.0 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), CSI Solar Co Ltd CS62-48TM-455H reaches 38.37 V per panel—exceeding 15 panels in series voids 600 V inverter warranties.
- Footprint constraint: 18 panels for an 8 kW build require 374 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 18 panels (374 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of CSI Solar Co Ltd CS62-48TM-455H carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
CSI Solar Co Ltd CS62-48TM-455H 8 kW Residential Fit
Needs 18 modules (374 sq ft) with a 25 A string OCPD, offsetting ~$2,050/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 15 panels (-10 C) or 15 panels (-20 C), or compare Hanersun Energy Co Ltd HN21RN-48HT455W.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 432.3 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for CSI Solar Co Ltd CS62-48TM-455H by CSI Solar Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
Why is CSI Solar Co Ltd CS62-48TM-455H PTC wattage (432.3 W) lower than STC (455.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 432.3 W PTC (95.0% retention) across CSI Solar Co Ltd CS62-48TM-455H's 1.93 m2 aperture.
Who should skip CSI Solar Co Ltd CS62-48TM-455H on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 18 CSI Solar Co Ltd CS62-48TM-455H panels (374 sq ft) leave unusable roof gaps vs. Hanersun Energy Co Ltd HN21RN-48HT455W.
What is the 1,000 V commercial string limit for CSI Solar Co Ltd CS62-48TM-455H?
On 1,000 V commercial inverters at -10 C (37.84 V cold Voc), CSI Solar Co Ltd CS62-48TM-455H fits up to 26 panels per series string.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)