Skip to main content
WireAndSun
Calculators
CEC PV Module

CSI Solar Co Ltd CS62-48TM-455H — CEC Solar Module Specifications

Manufacturer: CSI Solar Co Ltd Registry: CEC Verified Engineering Specification

CSI Solar Co Ltd CS62-48TM-455H is a 455.0 W STC (432.3 W PTC) Mono-c-Si solar module ranking #5,417 of 21,677 CEC listings (top 26.2%; higher than 73.8% of peers). It delivers 23.58% efficiency, 36.0 V Voc at 25 C, and 37.84 V cold Voc at -10 C (15 panels max per 600 V string).

STC Wattage
455.0 W
PTC Wattage
432.3 W
Voc @ 25C
36.0 V
Efficiency
23.58%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does CSI Solar Co Ltd CS62-48TM-455H Compare Against Peer CEC Listings?

How CSI Solar Co Ltd CSI Solar Co Ltd CS62-48TM-455H handles rooftop heat (432.3 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, CSI Solar Co Ltd CS62-48TM-455H exhibits 15.89 A short-circuit current, requiring a 24.79 A (156%) conductor rating and 25 A OCPD under NEC 690.8. Ranked #5,417 of 21,677 (45.0 W above the 410.0 W Mono-c-Si median), this modern high-density residential and light-commercial module covers 34.7 m2 for an 8 kW system (22 panels for 10 kW). Lower 36.0 V string voltage fits 15 panels in series at 14 F and pairs easily with microinverters.

Where Does CSI Solar Co Ltd CS62-48TM-455H Fall Across Listed CEC Models?

Where CSI Solar Co Ltd CS62-48TM-455H (455.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where CSI Solar Co Ltd CS62-48TM-455H (455.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCCSI Solar Co Ltd C: 455.0 W

What Dataset Percentiles Define CSI Solar Co Ltd CS62-48TM-455H?

Percentile placement of CSI Solar Co Ltd CS62-48TM-455H across power density (235.8 W/m2), thermal retention, and nameplate STC wattage.

CSI Solar Co Ltd CS62-48TM-455H Engineering BenchmarksPercentile comparison of CSI Solar Co Ltd CS62-48TM-455H wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage455.0 WPTC/STC Retention95.0%Module Efficiency23.58%

What Do the Dataset Ranks Show for CSI Solar Co Ltd CS62-48TM-455H?

Four critical engineering numbers homeowners and solar installers check first when reviewing CSI Solar Co Ltd CS62-48TM-455H specifications.

Rank #5,417 / 21,677

Top 26.2% STC Output

455.0 W STC (+70.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #450

23.58% Aperture Efficiency

Power density 235.8 W/m2 (3.67 percentage points above 19.91% CEC median). PTC/STC ratio: 95.0% (rank #1,106).

NEC 690.7 Limit

15 Panels Max @ -10 C (600 V)

Cold Voc reaches 37.84 V at -10 C (567.6 V string) and 38.37 V at -20 C (15 max).

8 kW Reference Array

18 Panels = 8,190 W STC

Occupies 34.7 m2 (374 sq ft) producing 7,781 W PTC; NEC 690.8 OCPD floor is 24.79 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 36.0 * (1 + (-0.146/100) * (-10 - 25)) = 37.84 V | OCPD = 1.56 * 15.89 = 24.79 A

Inputs from CEC Modules.csv for CSI Solar Co Ltd CS62-48TM-455H: Voc=36.0 V, beta_Voc=-0.146%/C, Isc=15.89 A, STC=455.0 W, Area=1.93 m2.

Result: 15 panels max on 600 V (567.6 V); 18 panels for 8 kW (374 sq ft).

What Are the Published CEC Specifications for CSI Solar Co Ltd CS62-48TM-455H?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for CSI Solar Co Ltd CS62-48TM-455H.

Official California Energy Commission (NREL SAM) test parameters for CSI Solar Co Ltd CS62-48TM-455H.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 455.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 432.3 W (95.0% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 36.0 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 15.89 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 30.8 V / 14.78 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.146 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 23.58% (1.93 m2) Array roof footprint density
Cell Count & Technology 48 cells (Mono-c-Si) Monofacial backsheet

How Many CSI Solar Co Ltd CS62-48TM-455H Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using CSI Solar Co Ltd CS62-48TM-455H (455.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 14 6.37 kW 291 sq ft $1,594 $2,696
8 kW Class 18 8.19 kW 374 sq ft $2,050 $3,466
10 kW Class 22 10.01 kW 457 sq ft $2,505 $4,236

Which Sibling Wattage & Trim Variants Belong to This CSI Solar Co Ltd Series?

All closely matched CSI Solar Co Ltd wattages and cosmetic trims sharing the CSI Solar Co Ltd CS62-48TM-455H architecture.

Sibling CEC listings grouped into the CSI Solar Co Ltd CS62-48TM-455H wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
CSI Solar Co Ltd CS62-48TM-450H 450.0 W 427.4 W 35.8 V 30.6 V 23.32%
CSI Solar Co Ltd CS62-48TM-455H 455.0 W 432.3 W 36.0 V 30.8 V 23.58%
CSI Solar Co Ltd CS62-48TM-460H 460.0 W 437.1 W 36.2 V 31.0 V 23.83%

How Many CSI Solar Co Ltd CS62-48TM-455H Modules Fit in a Cold-Weather String?

Maximum series module counts for CSI Solar Co Ltd CS62-48TM-455H from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=36.0V and beta_Voc=-0.146%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 38.37 V 15 panels 575.5 V 26 panels
-10 C (14 F) 37.84 V 15 panels 567.6 V 26 panels
0 C (32 F) 37.31 V 16 panels 597.0 V 26 panels
25 C (77 F STC) 36.0 V 16 panels 576.0 V 27 panels

Which Cross-Brand Solar Modules Compare Closest to CSI Solar Co Ltd CS62-48TM-455H?

Alternative CEC solar modules from competing brands near CSI Solar Co Ltd CS62-48TM-455H (455.0 W), including Hanersun Energy Co Ltd HN21RN-48HT455W.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Hanersun Energy Co Ltd HN21RN-48HT455W
Hanersun Energy Co Ltd
455.0 W Tie (0 W) 35.93 V 23.45% 95.1%
G-Star Pte Ltd GSD8R48T-460BT
G-Star Pte Ltd
460.0 W +5.0 W 35.99 V 23.23% 95.2%
G-Star Pte Ltd GSD8R48T-460WT
G-Star Pte Ltd
460.0 W +5.0 W 35.99 V 23.23% 95.2%
ELITE Solar ET-NR48TBH460GB
ELITE Solar
460.0 W +5.0 W 36.09 V 23.0% 95.1%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for CSI Solar Co Ltd CS62-48TM-455H?

Evaluate CSI Solar Co Ltd CS62-48TM-455H (455.0 W STC, 36.0 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), CSI Solar Co Ltd CS62-48TM-455H reaches 38.37 V per panel—exceeding 15 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 18 panels for an 8 kW build require 374 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 18 panels (374 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of CSI Solar Co Ltd CS62-48TM-455H carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

CSI Solar Co Ltd CS62-48TM-455H 8 kW Residential Fit

Needs 18 modules (374 sq ft) with a 25 A string OCPD, offsetting ~$2,050/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 15 panels (-10 C) or 15 panels (-20 C), or compare Hanersun Energy Co Ltd HN21RN-48HT455W.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 432.3 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for CSI Solar Co Ltd CS62-48TM-455H by CSI Solar Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.

Why is CSI Solar Co Ltd CS62-48TM-455H PTC wattage (432.3 W) lower than STC (455.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 432.3 W PTC (95.0% retention) across CSI Solar Co Ltd CS62-48TM-455H's 1.93 m2 aperture.

Who should skip CSI Solar Co Ltd CS62-48TM-455H on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 18 CSI Solar Co Ltd CS62-48TM-455H panels (374 sq ft) leave unusable roof gaps vs. Hanersun Energy Co Ltd HN21RN-48HT455W.

What is the 1,000 V commercial string limit for CSI Solar Co Ltd CS62-48TM-455H?

On 1,000 V commercial inverters at -10 C (37.84 V cold Voc), CSI Solar Co Ltd CS62-48TM-455H fits up to 26 panels per series string.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.