Hanersun Energy Co Ltd HN18-72HT555W is a 555.0 W STC (524.4 W PTC) Mono-c-Si solar module ranking #2,550 of 21,677 CEC listings (top 12.6%; higher than 87.4% of peers). It delivers 22.02% efficiency, 50.2 V Voc at 25 C, and 54.65 V cold Voc at -10 C (10 panels max per 600 V string).
- STC Wattage
- 555.0 W
- PTC Wattage
- 524.4 W
- Voc @ 25C
- 50.2 V
- Efficiency
- 22.02%
How Does Hanersun Energy Co Ltd HN18-72HT555W Compare Against Peer CEC Listings?
Solar engineering breakdown for Hanersun Energy Co Ltd HN18-72HT555W: PTC thermal retention, roof footprint, and cold Voc string bounds.
Across 5,889 Mono-c-Si listings from Hanersun Energy Co Ltd and peers, Hanersun Energy Co Ltd HN18-72HT555W stands 145.0 W above the 410.0 W Mono-c-Si median and strong 94.5% PTC-to-STC heat retention (#2,573 of 21,677). Sizing 6 kW (11 panels) to 10 kW (19 panels) yields $1,529-$2,638/yr in baseline US bill offset. Higher 50.2 V open-circuit voltage caps 600 V residential strings at 10 panels at 14 F (-10 C).
Where Does Hanersun Energy Co Ltd HN18-72HT555W Fall Across Listed CEC Models?
Distribution marker showing Hanersun Energy Co Ltd HN18-72HT555W (555.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define Hanersun Energy Co Ltd HN18-72HT555W?
Dataset percentiles tracking Hanersun Energy Co Ltd HN18-72HT555W power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for Hanersun Energy Co Ltd HN18-72HT555W?
Benchmark highlights for Hanersun Energy Co Ltd HN18-72HT555W covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
Top 12.6% STC Output
555.0 W STC (+170.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
22.02% Aperture Efficiency
Power density 220.2 W/m2 (2.11 percentage points above 19.91% CEC median). PTC/STC ratio: 94.5% (rank #2,573).
10 Panels Max @ -10 C (600 V)
Cold Voc reaches 54.65 V at -10 C (546.5 V string) and 55.92 V at -20 C (10 max).
15 Panels = 8,325 W STC
Occupies 37.8 m2 (407 sq ft) producing 7,866 W PTC; NEC 690.8 OCPD floor is 21.9 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 50.2 * (1 + (-0.253/100) * (-10 - 25)) = 54.65 V | OCPD = 1.56 * 14.04 = 21.9 A
Inputs from CEC Modules.csv for Hanersun Energy Co Ltd HN18-72HT555W: Voc=50.2 V, beta_Voc=-0.253%/C, Isc=14.04 A, STC=555.0 W, Area=2.52 m2.
Result: 10 panels max on 600 V (546.5 V); 15 panels for 8 kW (407 sq ft).
What Are the Published CEC Specifications for Hanersun Energy Co Ltd HN18-72HT555W?
Official CEC datasheet figures for Hanersun Energy Co Ltd HN18-72HT555W (Mono-c-Si) used in utility interconnection and permit reviews.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 555.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 524.4 W (94.5% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 50.2 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 14.04 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 42.26 V / 13.14 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.253 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 22.02% (2.52 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Bifacial glass-glass |
How Many Hanersun Energy Co Ltd HN18-72HT555W Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many Hanersun Energy Co Ltd HN18-72HT555W modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 11 | 6.11 kW | 298 sq ft | $1,529 | $2,586 |
| 8 kW Class | 15 | 8.32 kW | 407 sq ft | $2,082 | $3,521 |
| 10 kW Class | 19 | 10.54 kW | 515 sq ft | $2,638 | $4,461 |
Which Sibling Wattage & Trim Variants Belong to This Hanersun Energy Co Ltd Series?
Consolidated Hanersun Energy Co Ltd wattage variants sharing the Hanersun Energy Co Ltd HN18-72HT555W mechanical and cell layout.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Hanersun Energy Co Ltd HN18-72HT550W | 550.0 W | 519.5 W | 49.9 V | 41.96 V | 21.83% |
| Hanersun Energy Co Ltd HN18-72HT555W | 555.0 W | 524.4 W | 50.2 V | 42.26 V | 22.02% |
How Many Hanersun Energy Co Ltd HN18-72HT555W Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on Hanersun Energy Co Ltd HN18-72HT555W (54.65 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 55.92 V | 10 panels | 559.2 V | 17 panels |
| -10 C (14 F) | 54.65 V | 10 panels | 546.5 V | 18 panels |
| 0 C (32 F) | 53.38 V | 11 panels | 587.2 V | 18 panels |
| 25 C (77 F STC) | 50.2 V | 11 panels | 552.2 V | 19 panels |
Which Cross-Brand Solar Modules Compare Closest to Hanersun Energy Co Ltd HN18-72HT555W?
Competing CEC solar panels closest to Hanersun Energy Co Ltd HN18-72HT555W in nameplate wattage and Voc, starting with G-Star Pte Ltd GSP7G72M(H)555WT.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| G-Star Pte Ltd GSP7G72M(H)555WT G-Star Pte Ltd |
555.0 W | Tie (0 W) | 50.08 V | 21.68% | 94.1% |
| GCL System Integration Technology Co Ltd GCL-M10/72GDF555 GCL System Integration Technology Co Ltd |
555.0 W | Tie (0 W) | 50.08 V | 21.68% | 93.5% |
| AXITEC AC-555MBT/144V AXITEC |
555.0 W | Tie (0 W) | 50.05 V | 21.68% | 93.6% |
| AXITEC AC-555MBT/144VB AXITEC |
555.0 W | Tie (0 W) | 50.05 V | 21.68% | 93.6% |
What Are the Design Limits and Best-Fit Uses for Hanersun Energy Co Ltd HN18-72HT555W?
Evaluate Hanersun Energy Co Ltd HN18-72HT555W (555.0 W STC, 50.2 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Hanersun Energy Co Ltd HN18-72HT555W reaches 55.92 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 15 panels for an 8 kW build require 407 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of Hanersun Energy Co Ltd HN18-72HT555W carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Hanersun Energy Co Ltd HN18-72HT555W 8 kW Residential Fit
Needs 15 modules (407 sq ft) with a 25 A string OCPD, offsetting ~$2,082/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare G-Star Pte Ltd GSP7G72M(H)555WT.
Bifacial / High-Heat Roof Check
Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 524.4 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Hanersun Energy Co Ltd HN18-72HT555W by Hanersun Energy Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Hanersun Energy Co Ltd HN18-72HT555W?
Multiplying Hanersun Energy Co Ltd HN18-72HT555W's 14.04 A short-circuit current by 1.56 equals 21.9 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.
Can Hanersun Energy Co Ltd HN18-72HT555W pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 54.65 V cold Voc at 14 F and handles 14.04 A Isc; string inverters cap Hanersun Energy Co Ltd HN18-72HT555W at 10 panels on 600 V.
Is Hanersun Energy Co Ltd HN18-72HT555W eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Hanersun Energy Co Ltd HN18-72HT555W rely on utility bill offset (~$2,082/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)