First Solar Inc FS-4115A-3 is a 115.0 W STC (107.3 W PTC) Thin Film solar module ranking #21,511 of 21,677 CEC listings (below all-CEC median; higher than 0.7% of peers). It delivers 15.97% efficiency, 87.6 V Voc at 25 C, and 98.61 V cold Voc at -10 C (6 panels max per 600 V string).
- STC Wattage
- 115.0 W
- PTC Wattage
- 107.3 W
- Voc @ 25C
- 87.6 V
- Efficiency
- 15.97%
How Does First Solar Inc FS-4115A-3 Compare Against Peer CEC Listings?
Engineering position of First Solar Inc FS-4115A-3 (115.0 W STC) vs. Toledo Solar Inc TS1 across 106 CEC Thin Film solar modules.
Built with 216 Thin Film cells, First Solar Inc FS-4115A-3 pairs strong 93.3% PTC-to-STC heat retention (#8,323 of 21,677) with 87.6 V nominal Voc. An 8 kW residential build (8,050 W DC, 7,511 W PTC) saves ~$2,015/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer Toledo Solar Inc TS1 offers a 115.0 W alternative.
Where Does First Solar Inc FS-4115A-3 Fall Across Listed CEC Models?
Plots First Solar Inc FS-4115A-3 at 115.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.
What Dataset Percentiles Define First Solar Inc FS-4115A-3?
Benchmarks First Solar Inc FS-4115A-3 on STC wattage, thermal PTC/STC retention, and 15.97 aperture conversion efficiency against CEC peers.
What Do the Dataset Ranks Show for First Solar Inc FS-4115A-3?
Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for First Solar Inc FS-4115A-3 by First Solar Inc.
115.0 W STC · Higher Than 0.7%
115.0 W STC (-270.0 W vs all-CEC median) vs 117.5 W Thin Film median.
15.97% Aperture Efficiency
Power density 159.7 W/m2 (3.94 percentage points below 19.91% CEC median). PTC/STC ratio: 93.3% (rank #8,323).
6 Panels Max @ -10 C (600 V)
Cold Voc reaches 98.61 V at -10 C (591.7 V string) and 101.75 V at -20 C (5 max).
70 Panels = 8,050 W STC
Occupies 50.4 m2 (543 sq ft) producing 7,511 W PTC; NEC 690.8 OCPD floor is 2.85 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 87.6 * (1 + (-0.359/100) * (-10 - 25)) = 98.61 V | OCPD = 1.56 * 1.83 = 2.85 A
Inputs from CEC Modules.csv for First Solar Inc FS-4115A-3: Voc=87.6 V, beta_Voc=-0.359%/C, Isc=1.83 A, STC=115.0 W, Area=0.72 m2.
Result: 6 panels max on 600 V (591.7 V); 70 panels for 8 kW (543 sq ft).
What Are the Published CEC Specifications for First Solar Inc FS-4115A-3?
Laboratory test ratings recorded for First Solar Inc FS-4115A-3 (Thin Film) in the official California Energy Commission NREL SAM equipment catalog.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 115.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 107.3 W (93.3% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 87.6 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 1.83 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 69.3 V / 1.66 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.359 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 15.97% (0.72 m2) | Array roof footprint density |
| Cell Count & Technology | 216 cells (Thin Film) | Monofacial backsheet |
How Many First Solar Inc FS-4115A-3 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Panel counts, roof square footage (543 sq ft at 8 kW), and estimated Year-1 electric bill offset for First Solar Inc FS-4115A-3.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 53 | 6.09 kW | 411 sq ft | $1,524 | $2,577 |
| 8 kW Class | 70 | 8.05 kW | 543 sq ft | $2,015 | $3,407 |
| 10 kW Class | 87 | 10.01 kW | 674 sq ft | $2,505 | $4,236 |
How Many First Solar Inc FS-4115A-3 Modules Fit in a Cold-Weather String?
Cold-weather Voc escalation for First Solar Inc FS-4115A-3 (beta_Voc -0.359%/C) across 600 V residential and 1,000 V commercial inverters.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 101.75 V | 5 panels | 508.8 V | 9 panels |
| -10 C (14 F) | 98.61 V | 6 panels | 591.7 V | 10 panels |
| 0 C (32 F) | 95.46 V | 6 panels | 572.8 V | 10 panels |
| 25 C (77 F STC) | 87.6 V | 6 panels | 525.6 V | 11 panels |
Which Cross-Brand Solar Modules Compare Closest to First Solar Inc FS-4115A-3?
Closest cross-brand CEC competitors to First Solar Inc FS-4115A-3 matched near 115.0 W STC and 87.6 V Voc, led by Toledo Solar Inc TS1.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Toledo Solar Inc TS1 Toledo Solar Inc |
115.0 W | Tie (0 W) | 87.1 V | 15.97% | 92.9% |
| Caterpillar Inc PVT112 Caterpillar Inc |
112.5 W | -2.5 W | 87.7 V | 15.62% | 92.9% |
| Caterpillar Inc PVT112 ARC Caterpillar Inc |
112.5 W | -2.5 W | 87.7 V | 15.62% | 92.9% |
| T-Solar Global TS102 T-Solar Global |
102.5 W | -12.5 W | 93.0 V | 7.19% | 93.0% |
What Are the Design Limits and Best-Fit Uses for First Solar Inc FS-4115A-3?
Evaluate First Solar Inc FS-4115A-3 (115.0 W STC, 87.6 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), First Solar Inc FS-4115A-3 reaches 101.75 V per panel—exceeding 5 panels in series voids 600 V inverter warranties.
- Footprint constraint: 70 panels for an 8 kW build require 543 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 70 panels (543 sq ft).
- 2026 tax credit baseline: cash residential installs of First Solar Inc FS-4115A-3 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
First Solar Inc FS-4115A-3 8 kW Residential Fit
Needs 70 modules (543 sq ft) with a 15 A string OCPD, offsetting ~$2,015/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 6 panels (-10 C) or 5 panels (-20 C), or compare Toledo Solar Inc TS1.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 107.3 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for First Solar Inc FS-4115A-3 by First Solar Inc grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for First Solar Inc FS-4115A-3?
Multiplying First Solar Inc FS-4115A-3's 1.83 A short-circuit current by 1.56 equals 2.85 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.
Can First Solar Inc FS-4115A-3 pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 98.61 V cold Voc at 14 F and handles 1.83 A Isc; string inverters cap First Solar Inc FS-4115A-3 at 6 panels on 600 V.
Is First Solar Inc FS-4115A-3 eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of First Solar Inc FS-4115A-3 rely on utility bill offset (~$2,015/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)