Skip to main content
WireAndSun
Calculators
CEC PV Module

First Solar Inc FS-4115-2 — CEC Solar Module Specifications

Manufacturer: First Solar Inc Registry: CEC Verified Engineering Specification

First Solar Inc FS-4115-2 is a 115.0 W STC (105.2 W PTC) Thin Film solar module ranking #21,511 of 21,677 CEC listings (below all-CEC median; higher than 0.7% of peers). It delivers 15.97% efficiency, 87.8 V Voc at 25 C, and 98.71 V cold Voc at -10 C (6 panels max per 600 V string).

STC Wattage
115.0 W
PTC Wattage
105.2 W
Voc @ 25C
87.8 V
Efficiency
15.97%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does First Solar Inc FS-4115-2 Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for First Solar Inc FS-4115-2 (Thin Film) residential solar systems.

Homeowners evaluating First Solar Inc FS-4115-2 need 53 panels for 6 kW or 70 panels (543 sq ft) for an 8 kW array—useful on tight dormer roofs or battery cabins, though 8 kW requires 70 panels (543 sq ft). Under NEC 690.7(A), beta_Voc (-0.355%/C) pushes open-circuit voltage to 98.71 V at 14 F and 101.83 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

Where Does First Solar Inc FS-4115-2 Fall Across Listed CEC Models?

Comparison of First Solar Inc FS-4115-2 (115.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where First Solar Inc FS-4115-2 (115.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCFirst Solar Inc FS: 115.0 W

What Dataset Percentiles Define First Solar Inc FS-4115-2?

Relative ranking of First Solar Inc FS-4115-2 across nameplate watts, 91.5% PTC thermal ratio, and module aperture efficiency.

First Solar Inc FS-4115-2 Engineering BenchmarksPercentile comparison of First Solar Inc FS-4115-2 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage115.0 WPTC/STC Retention91.5%Module Efficiency15.97%

What Do the Dataset Ranks Show for First Solar Inc FS-4115-2?

Summary of First Solar Inc FS-4115-2 output rank, 8 kW array size (70 panels), efficiency rating, and 600 V string limit.

Rank #21,511 / 21,677

115.0 W STC · Higher Than 0.7%

115.0 W STC (-270.0 W vs all-CEC median) vs 117.5 W Thin Film median.

Eff #18,237

15.97% Aperture Efficiency

Power density 159.7 W/m2 (3.94 percentage points below 19.91% CEC median). PTC/STC ratio: 91.5% (rank #15,584).

NEC 690.7 Limit

6 Panels Max @ -10 C (600 V)

Cold Voc reaches 98.71 V at -10 C (592.3 V string) and 101.83 V at -20 C (5 max).

8 kW Reference Array

70 Panels = 8,050 W STC

Occupies 50.4 m2 (543 sq ft) producing 7,364 W PTC; NEC 690.8 OCPD floor is 2.78 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 87.8 * (1 + (-0.355/100) * (-10 - 25)) = 98.71 V | OCPD = 1.56 * 1.78 = 2.78 A

Inputs from CEC Modules.csv for First Solar Inc FS-4115-2: Voc=87.8 V, beta_Voc=-0.355%/C, Isc=1.78 A, STC=115.0 W, Area=0.72 m2.

Result: 6 panels max on 600 V (592.3 V); 70 panels for 8 kW (543 sq ft).

What Are the Published CEC Specifications for First Solar Inc FS-4115-2?

Complete CEC test sheet for First Solar Inc FS-4115-2 including Isc (1.78 A), Voc (87.8 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for First Solar Inc FS-4115-2.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 115.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 105.2 W (91.5% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 87.8 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 1.78 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 70.5 V / 1.63 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.355 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 15.97% (0.72 m2) Array roof footprint density
Cell Count & Technology 216 cells (Thin Film) Monofacial backsheet

How Many First Solar Inc FS-4115-2 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using First Solar Inc FS-4115-2.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 53 6.09 kW 411 sq ft $1,524 $2,577
8 kW Class 70 8.05 kW 543 sq ft $2,015 $3,407
10 kW Class 87 10.01 kW 674 sq ft $2,505 $4,236

How Many First Solar Inc FS-4115-2 Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for First Solar Inc FS-4115-2 (87.8 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=87.8V and beta_Voc=-0.355%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 101.83 V 5 panels 509.1 V 9 panels
-10 C (14 F) 98.71 V 6 panels 592.3 V 10 panels
0 C (32 F) 95.59 V 6 panels 573.5 V 10 panels
25 C (77 F STC) 87.8 V 6 panels 526.8 V 11 panels

Which Cross-Brand Solar Modules Compare Closest to First Solar Inc FS-4115-2?

Four comparable CEC modules such as Toledo Solar Inc TS1 (115.0 W) for side-by-side solar quote checks. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Toledo Solar Inc TS1
Toledo Solar Inc
115.0 W Tie (0 W) 87.1 V 15.97% 92.9%
Caterpillar Inc PVT112
Caterpillar Inc
112.5 W -2.5 W 87.7 V 15.62% 92.9%
Caterpillar Inc PVT112 ARC
Caterpillar Inc
112.5 W -2.5 W 87.7 V 15.62% 92.9%
T-Solar Global TS102
T-Solar Global
102.5 W -12.5 W 93.0 V 7.19% 93.0%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for First Solar Inc FS-4115-2?

Evaluate First Solar Inc FS-4115-2 (115.0 W STC, 87.8 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), First Solar Inc FS-4115-2 reaches 101.83 V per panel—exceeding 5 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 70 panels for an 8 kW build require 543 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 70 panels (543 sq ft).
  • 2026 tax credit baseline: cash residential installs of First Solar Inc FS-4115-2 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

First Solar Inc FS-4115-2 8 kW Residential Fit

Needs 70 modules (543 sq ft) with a 15 A string OCPD, offsetting ~$2,015/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 6 panels (-10 C) or 5 panels (-20 C), or compare Toledo Solar Inc TS1.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 105.2 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for First Solar Inc FS-4115-2 by First Solar Inc grounded in CEC test data and NEC 690.7/690.8 limits.

Why is First Solar Inc FS-4115-2 PTC wattage (105.2 W) lower than STC (115.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 105.2 W PTC (91.5% retention) across First Solar Inc FS-4115-2's 0.72 m2 aperture.

Who should skip First Solar Inc FS-4115-2 on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 70 First Solar Inc FS-4115-2 panels (543 sq ft) leave unusable roof gaps vs. Toledo Solar Inc TS1.

What is the 1,000 V commercial string limit for First Solar Inc FS-4115-2?

On 1,000 V commercial inverters at -10 C (98.71 V cold Voc), First Solar Inc FS-4115-2 fits up to 10 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting First Solar Inc FS-4115-2.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.