Skip to main content
WireAndSun
Calculators
CEC PV Module

First Solar Inc FS-4110A-3 — CEC Solar Module Specifications

Manufacturer: First Solar Inc Registry: CEC Verified Engineering Specification

First Solar Inc FS-4110A-3 is a 110.0 W STC (102.6 W PTC) Thin Film solar module ranking #21,527 of 21,677 CEC listings (below all-CEC median; higher than 0.7% of peers). It delivers 15.28% efficiency, 86.4 V Voc at 25 C, and 97.26 V cold Voc at -10 C (6 panels max per 600 V string).

STC Wattage
110.0 W
PTC Wattage
102.6 W
Voc @ 25C
86.4 V
Efficiency
15.28%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does First Solar Inc FS-4110A-3 Compare Against Peer CEC Listings?

Solar engineering breakdown for First Solar Inc FS-4110A-3: PTC thermal retention, roof footprint, and cold Voc string bounds.

Across 106 Thin Film listings from First Solar Inc and peers, First Solar Inc FS-4110A-3 stands 7.5 W below the 117.5 W Thin Film median and strong 93.3% PTC-to-STC heat retention (#8,323 of 21,677). Sizing 6 kW (55 panels) to 10 kW (91 panels) yields $1,514-$2,505/yr in baseline US bill offset. Higher 86.4 V open-circuit voltage caps 600 V residential strings at 6 panels at 14 F (-10 C).

Where Does First Solar Inc FS-4110A-3 Fall Across Listed CEC Models?

Distribution marker showing First Solar Inc FS-4110A-3 (110.0 W) relative to the 385.0 W all-CEC solar panel median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where First Solar Inc FS-4110A-3 (110.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCFirst Solar Inc FS: 110.0 W

What Dataset Percentiles Define First Solar Inc FS-4110A-3?

Dataset percentiles tracking First Solar Inc FS-4110A-3 power output, thermal retention ratio, and aperture efficiency against 21,677 models.

First Solar Inc FS-4110A-3 Engineering BenchmarksPercentile comparison of First Solar Inc FS-4110A-3 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage110.0 WPTC/STC Retention93.3%Module Efficiency15.28%

What Do the Dataset Ranks Show for First Solar Inc FS-4110A-3?

Benchmark highlights for First Solar Inc FS-4110A-3 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #21,527 / 21,677

110.0 W STC · Higher Than 0.7%

110.0 W STC (-275.0 W vs all-CEC median) vs 117.5 W Thin Film median.

Eff #19,278

15.28% Aperture Efficiency

Power density 152.8 W/m2 (4.63 percentage points below 19.91% CEC median). PTC/STC ratio: 93.3% (rank #8,323).

NEC 690.7 Limit

6 Panels Max @ -10 C (600 V)

Cold Voc reaches 97.26 V at -10 C (583.6 V string) and 100.36 V at -20 C (5 max).

8 kW Reference Array

73 Panels = 8,030 W STC

Occupies 52.6 m2 (566 sq ft) producing 7,490 W PTC; NEC 690.8 OCPD floor is 2.84 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 86.4 * (1 + (-0.359/100) * (-10 - 25)) = 97.26 V | OCPD = 1.56 * 1.82 = 2.84 A

Inputs from CEC Modules.csv for First Solar Inc FS-4110A-3: Voc=86.4 V, beta_Voc=-0.359%/C, Isc=1.82 A, STC=110.0 W, Area=0.72 m2.

Result: 6 panels max on 600 V (583.6 V); 73 panels for 8 kW (566 sq ft).

What Are the Published CEC Specifications for First Solar Inc FS-4110A-3?

Official CEC datasheet figures for First Solar Inc FS-4110A-3 (Thin Film) used in utility interconnection and permit reviews.

Official California Energy Commission (NREL SAM) test parameters for First Solar Inc FS-4110A-3.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 110.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 102.6 W (93.3% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 86.4 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 1.82 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 67.8 V / 1.62 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.359 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 15.28% (0.72 m2) Array roof footprint density
Cell Count & Technology 216 cells (Thin Film) Monofacial backsheet

How Many First Solar Inc FS-4110A-3 Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many First Solar Inc FS-4110A-3 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 55 6.05 kW 426 sq ft $1,514 $2,561
8 kW Class 73 8.03 kW 566 sq ft $2,010 $3,398
10 kW Class 91 10.01 kW 705 sq ft $2,505 $4,236

How Many First Solar Inc FS-4110A-3 Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on First Solar Inc FS-4110A-3 (97.26 V at 14 F).

Computed from Voc=86.4V and beta_Voc=-0.359%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 100.36 V 5 panels 501.8 V 9 panels
-10 C (14 F) 97.26 V 6 panels 583.6 V 10 panels
0 C (32 F) 94.15 V 6 panels 564.9 V 10 panels
25 C (77 F STC) 86.4 V 6 panels 518.4 V 11 panels

Which Cross-Brand Solar Modules Compare Closest to First Solar Inc FS-4110A-3?

Competing CEC solar panels closest to First Solar Inc FS-4110A-3 in nameplate wattage and Voc, starting with Caterpillar Inc PVT112.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Caterpillar Inc PVT112
Caterpillar Inc
112.5 W +2.5 W 87.7 V 15.62% 92.9%
Caterpillar Inc PVT112 ARC
Caterpillar Inc
112.5 W +2.5 W 87.7 V 15.62% 92.9%
Toledo Solar Inc TS1
Toledo Solar Inc
115.0 W +5.0 W 87.1 V 15.97% 92.9%
T-Solar Global TS102
T-Solar Global
102.5 W -7.5 W 93.0 V 7.19% 93.0%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for First Solar Inc FS-4110A-3?

Evaluate First Solar Inc FS-4110A-3 (110.0 W STC, 86.4 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), First Solar Inc FS-4110A-3 reaches 100.36 V per panel—exceeding 5 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 73 panels for an 8 kW build require 566 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 73 panels (566 sq ft).
  • 2026 tax credit baseline: cash residential installs of First Solar Inc FS-4110A-3 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

First Solar Inc FS-4110A-3 8 kW Residential Fit

Needs 73 modules (566 sq ft) with a 15 A string OCPD, offsetting ~$2,010/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 6 panels (-10 C) or 5 panels (-20 C), or compare Caterpillar Inc PVT112.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 102.6 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for First Solar Inc FS-4110A-3 by First Solar Inc grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for First Solar Inc FS-4110A-3?

Multiplying First Solar Inc FS-4110A-3's 1.82 A short-circuit current by 1.56 equals 2.84 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

Can First Solar Inc FS-4110A-3 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 97.26 V cold Voc at 14 F and handles 1.82 A Isc; string inverters cap First Solar Inc FS-4110A-3 at 6 panels on 600 V.

Is First Solar Inc FS-4110A-3 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of First Solar Inc FS-4110A-3 rely on utility bill offset (~$2,010/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.