First Solar Inc FS-4107A-2 is a 107.5 W STC (99.7 W PTC) Thin Film solar module ranking #21,537 of 21,677 CEC listings (below all-CEC median; higher than 0.6% of peers). It delivers 14.93% efficiency, 86.6 V Voc at 25 C, and 94.72 V cold Voc at -10 C (6 panels max per 600 V string).
- STC Wattage
- 107.5 W
- PTC Wattage
- 99.7 W
- Voc @ 25C
- 86.6 V
- Efficiency
- 14.93%
How Does First Solar Inc FS-4107A-2 Compare Against Peer CEC Listings?
Engineering position of First Solar Inc FS-4107A-2 (107.5 W STC) vs. Caterpillar Inc PVT112 across 106 CEC Thin Film solar modules.
Built with 216 Thin Film cells, First Solar Inc FS-4107A-2 pairs strong 92.7% PTC-to-STC heat retention (#11,468 of 21,677) with 86.6 V nominal Voc. An 8 kW residential build (8,062 W DC, 7,478 W PTC) saves ~$2,017/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer Caterpillar Inc PVT112 offers a 112.5 W alternative.
Where Does First Solar Inc FS-4107A-2 Fall Across Listed CEC Models?
Plots First Solar Inc FS-4107A-2 at 107.5 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.
What Dataset Percentiles Define First Solar Inc FS-4107A-2?
Benchmarks First Solar Inc FS-4107A-2 on STC wattage, thermal PTC/STC retention, and 14.93 aperture conversion efficiency against CEC peers.
What Do the Dataset Ranks Show for First Solar Inc FS-4107A-2?
Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for First Solar Inc FS-4107A-2 by First Solar Inc.
107.5 W STC · Higher Than 0.6%
107.5 W STC (-277.5 W vs all-CEC median) vs 117.5 W Thin Film median.
14.93% Aperture Efficiency
Power density 149.3 W/m2 (4.98 percentage points below 19.91% CEC median). PTC/STC ratio: 92.7% (rank #11,468).
6 Panels Max @ -10 C (600 V)
Cold Voc reaches 94.72 V at -10 C (568.3 V string) and 97.04 V at -20 C (6 max).
75 Panels = 8,062 W STC
Occupies 54.0 m2 (581 sq ft) producing 7,478 W PTC; NEC 690.8 OCPD floor is 2.73 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 86.6 * (1 + (-0.268/100) * (-10 - 25)) = 94.72 V | OCPD = 1.56 * 1.75 = 2.73 A
Inputs from CEC Modules.csv for First Solar Inc FS-4107A-2: Voc=86.6 V, beta_Voc=-0.268%/C, Isc=1.75 A, STC=107.5 W, Area=0.72 m2.
Result: 6 panels max on 600 V (568.3 V); 75 panels for 8 kW (581 sq ft).
What Are the Published CEC Specifications for First Solar Inc FS-4107A-2?
Laboratory test ratings recorded for First Solar Inc FS-4107A-2 (Thin Film) in the official California Energy Commission NREL SAM equipment catalog.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 107.5 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 99.7 W (92.7% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 86.6 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 1.75 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 68.6 V / 1.57 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.268 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 14.93% (0.72 m2) | Array roof footprint density |
| Cell Count & Technology | 216 cells (Thin Film) | Monofacial backsheet |
How Many First Solar Inc FS-4107A-2 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Panel counts, roof square footage (581 sq ft at 8 kW), and estimated Year-1 electric bill offset for First Solar Inc FS-4107A-2.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 56 | 6.02 kW | 434 sq ft | $1,507 | $2,548 |
| 8 kW Class | 75 | 8.06 kW | 581 sq ft | $2,017 | $3,411 |
| 10 kW Class | 94 | 10.11 kW | 729 sq ft | $2,530 | $4,279 |
How Many First Solar Inc FS-4107A-2 Modules Fit in a Cold-Weather String?
Cold-weather Voc escalation for First Solar Inc FS-4107A-2 (beta_Voc -0.268%/C) across 600 V residential and 1,000 V commercial inverters.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 97.04 V | 6 panels | 582.2 V | 10 panels |
| -10 C (14 F) | 94.72 V | 6 panels | 568.3 V | 10 panels |
| 0 C (32 F) | 92.4 V | 6 panels | 554.4 V | 10 panels |
| 25 C (77 F STC) | 86.6 V | 6 panels | 519.6 V | 11 panels |
Which Cross-Brand Solar Modules Compare Closest to First Solar Inc FS-4107A-2?
Closest cross-brand CEC competitors to First Solar Inc FS-4107A-2 matched near 107.5 W STC and 86.6 V Voc, led by Caterpillar Inc PVT112.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Caterpillar Inc PVT112 Caterpillar Inc |
112.5 W | +5.0 W | 87.7 V | 15.62% | 92.9% |
| Caterpillar Inc PVT112 ARC Caterpillar Inc |
112.5 W | +5.0 W | 87.7 V | 15.62% | 92.9% |
| Toledo Solar Inc TS1 Toledo Solar Inc |
115.0 W | +7.5 W | 87.1 V | 15.97% | 92.9% |
| T-Solar Global TS102 T-Solar Global |
102.5 W | -5.0 W | 93.0 V | 7.19% | 93.0% |
What Are the Design Limits and Best-Fit Uses for First Solar Inc FS-4107A-2?
Evaluate First Solar Inc FS-4107A-2 (107.5 W STC, 86.6 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), First Solar Inc FS-4107A-2 reaches 97.04 V per panel—exceeding 6 panels in series voids 600 V inverter warranties.
- Footprint constraint: 75 panels for an 8 kW build require 581 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 75 panels (581 sq ft).
- 2026 tax credit baseline: cash residential installs of First Solar Inc FS-4107A-2 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
First Solar Inc FS-4107A-2 8 kW Residential Fit
Needs 75 modules (581 sq ft) with a 15 A string OCPD, offsetting ~$2,017/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 6 panels (-10 C) or 6 panels (-20 C), or compare Caterpillar Inc PVT112.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 99.7 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for First Solar Inc FS-4107A-2 by First Solar Inc grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for First Solar Inc FS-4107A-2?
Multiplying First Solar Inc FS-4107A-2's 1.75 A short-circuit current by 1.56 equals 2.73 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.
Can First Solar Inc FS-4107A-2 pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 94.72 V cold Voc at 14 F and handles 1.75 A Isc; string inverters cap First Solar Inc FS-4107A-2 at 6 panels on 600 V.
Is First Solar Inc FS-4107A-2 eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of First Solar Inc FS-4107A-2 rely on utility bill offset (~$2,017/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)