Skip to main content
WireAndSun
Calculators
CEC PV Module

First Solar Inc FS-4105-2 — CEC Solar Module Specifications

Manufacturer: First Solar Inc Registry: CEC Verified Engineering Specification

First Solar Inc FS-4105-2 is a 105.0 W STC (97.4 W PTC) Thin Film solar module ranking #21,543 of 21,677 CEC listings (below all-CEC median; higher than 0.6% of peers). It delivers 14.58% efficiency, 86.0 V Voc at 25 C, and 94.07 V cold Voc at -10 C (6 panels max per 600 V string).

STC Wattage
105.0 W
PTC Wattage
97.4 W
Voc @ 25C
86.0 V
Efficiency
14.58%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does First Solar Inc FS-4105-2 Compare Against Peer CEC Listings?

How First Solar Inc First Solar Inc FS-4105-2 handles rooftop heat (97.4 W PTC), 8 kW sizing, and cold winter string voltage.

First Solar Inc builds the First Solar Inc FS-4105-2 (Thin Film) as a compact residential or specialty off-grid module delivering 145.8 W/m2 (5.33 percentage points below 19.91% CEC median). Compared against Caterpillar Inc PVT112 (112.5 W), this model holds strong 92.8% PTC-to-STC heat retention (#10,898 of 21,677). Higher 86.0 V open-circuit voltage caps 600 V residential strings at 6 panels at 14 F (-10 C), while NEC 690.8 sets a 2.71 A overcurrent floor served by a 15 A breaker.

Where Does First Solar Inc FS-4105-2 Fall Across Listed CEC Models?

Where First Solar Inc FS-4105-2 (105.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where First Solar Inc FS-4105-2 (105.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCFirst Solar Inc FS: 105.0 W

What Dataset Percentiles Define First Solar Inc FS-4105-2?

Percentile placement of First Solar Inc FS-4105-2 across power density (145.8 W/m2), thermal retention, and nameplate STC wattage.

First Solar Inc FS-4105-2 Engineering BenchmarksPercentile comparison of First Solar Inc FS-4105-2 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage105.0 WPTC/STC Retention92.8%Module Efficiency14.58%

What Do the Dataset Ranks Show for First Solar Inc FS-4105-2?

Four critical engineering numbers homeowners and solar installers check first when reviewing First Solar Inc FS-4105-2 specifications. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Rank #21,543 / 21,677

105.0 W STC · Higher Than 0.6%

105.0 W STC (-280.0 W vs all-CEC median) vs 117.5 W Thin Film median.

Eff #20,303

14.58% Aperture Efficiency

Power density 145.8 W/m2 (5.33 percentage points below 19.91% CEC median). PTC/STC ratio: 92.8% (rank #10,898).

NEC 690.7 Limit

6 Panels Max @ -10 C (600 V)

Cold Voc reaches 94.07 V at -10 C (564.4 V string) and 96.37 V at -20 C (6 max).

8 kW Reference Array

77 Panels = 8,085 W STC

Occupies 55.4 m2 (597 sq ft) producing 7,500 W PTC; NEC 690.8 OCPD floor is 2.71 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 86.0 * (1 + (-0.268/100) * (-10 - 25)) = 94.07 V | OCPD = 1.56 * 1.74 = 2.71 A

Inputs from CEC Modules.csv for First Solar Inc FS-4105-2: Voc=86.0 V, beta_Voc=-0.268%/C, Isc=1.74 A, STC=105.0 W, Area=0.72 m2.

Result: 6 panels max on 600 V (564.4 V); 77 panels for 8 kW (597 sq ft).

What Are the Published CEC Specifications for First Solar Inc FS-4105-2?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for First Solar Inc FS-4105-2.

Official California Energy Commission (NREL SAM) test parameters for First Solar Inc FS-4105-2.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 105.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 97.4 W (92.8% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 86.0 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 1.74 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 67.8 V / 1.55 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.268 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 14.58% (0.72 m2) Array roof footprint density
Cell Count & Technology 216 cells (Thin Film) Monofacial backsheet

How Many First Solar Inc FS-4105-2 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using First Solar Inc FS-4105-2 (105.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 58 6.09 kW 450 sq ft $1,524 $2,577
8 kW Class 77 8.09 kW 597 sq ft $2,025 $3,424
10 kW Class 96 10.08 kW 744 sq ft $2,523 $4,266

How Many First Solar Inc FS-4105-2 Modules Fit in a Cold-Weather String?

Maximum series module counts for First Solar Inc FS-4105-2 from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=86.0V and beta_Voc=-0.268%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 96.37 V 6 panels 578.2 V 10 panels
-10 C (14 F) 94.07 V 6 panels 564.4 V 10 panels
0 C (32 F) 91.76 V 6 panels 550.6 V 10 panels
25 C (77 F STC) 86.0 V 6 panels 516.0 V 11 panels

Which Cross-Brand Solar Modules Compare Closest to First Solar Inc FS-4105-2?

Alternative CEC solar modules from competing brands near First Solar Inc FS-4105-2 (105.0 W), including Caterpillar Inc PVT112.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Caterpillar Inc PVT112
Caterpillar Inc
112.5 W +7.5 W 87.7 V 15.62% 92.9%
Caterpillar Inc PVT112 ARC
Caterpillar Inc
112.5 W +7.5 W 87.7 V 15.62% 92.9%
Toledo Solar Inc TS1
Toledo Solar Inc
115.0 W +10.0 W 87.1 V 15.97% 92.9%
T-Solar Global TS102
T-Solar Global
102.5 W -2.5 W 93.0 V 7.19% 93.0%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for First Solar Inc FS-4105-2?

Evaluate First Solar Inc FS-4105-2 (105.0 W STC, 86.0 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), First Solar Inc FS-4105-2 reaches 96.37 V per panel—exceeding 6 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 77 panels for an 8 kW build require 597 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 77 panels (597 sq ft).
  • 2026 tax credit baseline: cash residential installs of First Solar Inc FS-4105-2 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

First Solar Inc FS-4105-2 8 kW Residential Fit

Needs 77 modules (597 sq ft) with a 15 A string OCPD, offsetting ~$2,025/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 6 panels (-10 C) or 6 panels (-20 C), or compare Caterpillar Inc PVT112.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 97.4 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for First Solar Inc FS-4105-2 by First Solar Inc grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for First Solar Inc FS-4105-2?

Multiplying First Solar Inc FS-4105-2's 1.74 A short-circuit current by 1.56 equals 2.71 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

Can First Solar Inc FS-4105-2 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 94.07 V cold Voc at 14 F and handles 1.74 A Isc; string inverters cap First Solar Inc FS-4105-2 at 6 panels on 600 V.

Is First Solar Inc FS-4105-2 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of First Solar Inc FS-4105-2 rely on utility bill offset (~$2,025/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.