First Solar Inc FS-4105-2 is a 105.0 W STC (97.4 W PTC) Thin Film solar module ranking #21,543 of 21,677 CEC listings (below all-CEC median; higher than 0.6% of peers). It delivers 14.58% efficiency, 86.0 V Voc at 25 C, and 94.07 V cold Voc at -10 C (6 panels max per 600 V string).
- STC Wattage
- 105.0 W
- PTC Wattage
- 97.4 W
- Voc @ 25C
- 86.0 V
- Efficiency
- 14.58%
How Does First Solar Inc FS-4105-2 Compare Against Peer CEC Listings?
How First Solar Inc First Solar Inc FS-4105-2 handles rooftop heat (97.4 W PTC), 8 kW sizing, and cold winter string voltage.
First Solar Inc builds the First Solar Inc FS-4105-2 (Thin Film) as a compact residential or specialty off-grid module delivering 145.8 W/m2 (5.33 percentage points below 19.91% CEC median). Compared against Caterpillar Inc PVT112 (112.5 W), this model holds strong 92.8% PTC-to-STC heat retention (#10,898 of 21,677). Higher 86.0 V open-circuit voltage caps 600 V residential strings at 6 panels at 14 F (-10 C), while NEC 690.8 sets a 2.71 A overcurrent floor served by a 15 A breaker.
Where Does First Solar Inc FS-4105-2 Fall Across Listed CEC Models?
Where First Solar Inc FS-4105-2 (105.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define First Solar Inc FS-4105-2?
Percentile placement of First Solar Inc FS-4105-2 across power density (145.8 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for First Solar Inc FS-4105-2?
Four critical engineering numbers homeowners and solar installers check first when reviewing First Solar Inc FS-4105-2 specifications. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.
105.0 W STC · Higher Than 0.6%
105.0 W STC (-280.0 W vs all-CEC median) vs 117.5 W Thin Film median.
14.58% Aperture Efficiency
Power density 145.8 W/m2 (5.33 percentage points below 19.91% CEC median). PTC/STC ratio: 92.8% (rank #10,898).
6 Panels Max @ -10 C (600 V)
Cold Voc reaches 94.07 V at -10 C (564.4 V string) and 96.37 V at -20 C (6 max).
77 Panels = 8,085 W STC
Occupies 55.4 m2 (597 sq ft) producing 7,500 W PTC; NEC 690.8 OCPD floor is 2.71 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 86.0 * (1 + (-0.268/100) * (-10 - 25)) = 94.07 V | OCPD = 1.56 * 1.74 = 2.71 A
Inputs from CEC Modules.csv for First Solar Inc FS-4105-2: Voc=86.0 V, beta_Voc=-0.268%/C, Isc=1.74 A, STC=105.0 W, Area=0.72 m2.
Result: 6 panels max on 600 V (564.4 V); 77 panels for 8 kW (597 sq ft).
What Are the Published CEC Specifications for First Solar Inc FS-4105-2?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for First Solar Inc FS-4105-2.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 105.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 97.4 W (92.8% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 86.0 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 1.74 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 67.8 V / 1.55 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.268 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 14.58% (0.72 m2) | Array roof footprint density |
| Cell Count & Technology | 216 cells (Thin Film) | Monofacial backsheet |
How Many First Solar Inc FS-4105-2 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using First Solar Inc FS-4105-2 (105.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 58 | 6.09 kW | 450 sq ft | $1,524 | $2,577 |
| 8 kW Class | 77 | 8.09 kW | 597 sq ft | $2,025 | $3,424 |
| 10 kW Class | 96 | 10.08 kW | 744 sq ft | $2,523 | $4,266 |
How Many First Solar Inc FS-4105-2 Modules Fit in a Cold-Weather String?
Maximum series module counts for First Solar Inc FS-4105-2 from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 96.37 V | 6 panels | 578.2 V | 10 panels |
| -10 C (14 F) | 94.07 V | 6 panels | 564.4 V | 10 panels |
| 0 C (32 F) | 91.76 V | 6 panels | 550.6 V | 10 panels |
| 25 C (77 F STC) | 86.0 V | 6 panels | 516.0 V | 11 panels |
Which Cross-Brand Solar Modules Compare Closest to First Solar Inc FS-4105-2?
Alternative CEC solar modules from competing brands near First Solar Inc FS-4105-2 (105.0 W), including Caterpillar Inc PVT112.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Caterpillar Inc PVT112 Caterpillar Inc |
112.5 W | +7.5 W | 87.7 V | 15.62% | 92.9% |
| Caterpillar Inc PVT112 ARC Caterpillar Inc |
112.5 W | +7.5 W | 87.7 V | 15.62% | 92.9% |
| Toledo Solar Inc TS1 Toledo Solar Inc |
115.0 W | +10.0 W | 87.1 V | 15.97% | 92.9% |
| T-Solar Global TS102 T-Solar Global |
102.5 W | -2.5 W | 93.0 V | 7.19% | 93.0% |
What Are the Design Limits and Best-Fit Uses for First Solar Inc FS-4105-2?
Evaluate First Solar Inc FS-4105-2 (105.0 W STC, 86.0 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), First Solar Inc FS-4105-2 reaches 96.37 V per panel—exceeding 6 panels in series voids 600 V inverter warranties.
- Footprint constraint: 77 panels for an 8 kW build require 597 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 77 panels (597 sq ft).
- 2026 tax credit baseline: cash residential installs of First Solar Inc FS-4105-2 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
First Solar Inc FS-4105-2 8 kW Residential Fit
Needs 77 modules (597 sq ft) with a 15 A string OCPD, offsetting ~$2,025/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 6 panels (-10 C) or 6 panels (-20 C), or compare Caterpillar Inc PVT112.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 97.4 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for First Solar Inc FS-4105-2 by First Solar Inc grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for First Solar Inc FS-4105-2?
Multiplying First Solar Inc FS-4105-2's 1.74 A short-circuit current by 1.56 equals 2.71 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.
Can First Solar Inc FS-4105-2 pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 94.07 V cold Voc at 14 F and handles 1.74 A Isc; string inverters cap First Solar Inc FS-4105-2 at 6 panels on 600 V.
Is First Solar Inc FS-4105-2 eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of First Solar Inc FS-4105-2 rely on utility bill offset (~$2,025/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)