First Solar Inc FS-4102-2 is a 102.5 W STC (95.0 W PTC) Thin Film solar module ranking #21,557 of 21,677 CEC listings (below all-CEC median; higher than 0.5% of peers). It delivers 14.24% efficiency, 85.3 V Voc at 25 C, and 93.3 V cold Voc at -10 C (6 panels max per 600 V string).
- STC Wattage
- 102.5 W
- PTC Wattage
- 95.0 W
- Voc @ 25C
- 85.3 V
- Efficiency
- 14.24%
How Does First Solar Inc FS-4102-2 Compare Against Peer CEC Listings?
CEC rank, roof space requirements, and NEC 690.7/690.8 limits for First Solar Inc FS-4102-2 (Thin Film) residential solar systems.
First Solar Inc FS-4102-2 delivers 142.4 W/m2 (5.67 percentage points below 19.91% CEC median) and strong 92.7% PTC-to-STC heat retention (#11,468 of 21,677), placing it as a compact residential or specialty off-grid module useful on tight dormer roofs or battery cabins, though 8 kW requires 79 panels (612 sq ft). At -4 F (-20 C), string voltage climbs to 95.59 V per unit, capping 600 V circuits at 6 panels. Compare specs directly with Caterpillar Inc PVT112 (112.5 W).
Where Does First Solar Inc FS-4102-2 Fall Across Listed CEC Models?
Comparison of First Solar Inc FS-4102-2 (102.5 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.
What Dataset Percentiles Define First Solar Inc FS-4102-2?
Relative ranking of First Solar Inc FS-4102-2 across nameplate watts, 92.7% PTC thermal ratio, and module aperture efficiency.
What Do the Dataset Ranks Show for First Solar Inc FS-4102-2?
Summary of First Solar Inc FS-4102-2 output rank, 8 kW array size (79 panels), efficiency rating, and 600 V string limit.
102.5 W STC · Higher Than 0.5%
102.5 W STC (-282.5 W vs all-CEC median) vs 117.5 W Thin Film median.
14.24% Aperture Efficiency
Power density 142.4 W/m2 (5.67 percentage points below 19.91% CEC median). PTC/STC ratio: 92.7% (rank #11,468).
6 Panels Max @ -10 C (600 V)
Cold Voc reaches 93.3 V at -10 C (559.8 V string) and 95.59 V at -20 C (6 max).
79 Panels = 8,098 W STC
Occupies 56.9 m2 (612 sq ft) producing 7,505 W PTC; NEC 690.8 OCPD floor is 2.71 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 85.3 * (1 + (-0.268/100) * (-10 - 25)) = 93.3 V | OCPD = 1.56 * 1.74 = 2.71 A
Inputs from CEC Modules.csv for First Solar Inc FS-4102-2: Voc=85.3 V, beta_Voc=-0.268%/C, Isc=1.74 A, STC=102.5 W, Area=0.72 m2.
Result: 6 panels max on 600 V (559.8 V); 79 panels for 8 kW (612 sq ft).
What Are the Published CEC Specifications for First Solar Inc FS-4102-2?
Complete CEC test sheet for First Solar Inc FS-4102-2 including Isc (1.74 A), Voc (85.3 V), and thermal temperature coefficients.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 102.5 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 95.0 W (92.7% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 85.3 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 1.74 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 67.0 V / 1.53 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.268 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 14.24% (0.72 m2) | Array roof footprint density |
| Cell Count & Technology | 216 cells (Thin Film) | Monofacial backsheet |
How Many First Solar Inc FS-4102-2 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using First Solar Inc FS-4102-2.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 59 | 6.05 kW | 457 sq ft | $1,514 | $2,561 |
| 8 kW Class | 79 | 8.1 kW | 612 sq ft | $2,027 | $3,428 |
| 10 kW Class | 98 | 10.04 kW | 760 sq ft | $2,513 | $4,249 |
How Many First Solar Inc FS-4102-2 Modules Fit in a Cold-Weather String?
Verify freezing-morning voltage rise for First Solar Inc FS-4102-2 (85.3 V STC) before wiring 600 V or 1,000 V strings.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 95.59 V | 6 panels | 573.5 V | 10 panels |
| -10 C (14 F) | 93.3 V | 6 panels | 559.8 V | 10 panels |
| 0 C (32 F) | 91.02 V | 6 panels | 546.1 V | 10 panels |
| 25 C (77 F STC) | 85.3 V | 7 panels | 597.1 V | 11 panels |
Which Cross-Brand Solar Modules Compare Closest to First Solar Inc FS-4102-2?
Four comparable CEC modules such as Caterpillar Inc PVT112 (112.5 W) for side-by-side solar quote checks. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Caterpillar Inc PVT112 Caterpillar Inc |
112.5 W | +10.0 W | 87.7 V | 15.62% | 92.9% |
| Caterpillar Inc PVT112 ARC Caterpillar Inc |
112.5 W | +10.0 W | 87.7 V | 15.62% | 92.9% |
| Toledo Solar Inc TS1 Toledo Solar Inc |
115.0 W | +12.5 W | 87.1 V | 15.97% | 92.9% |
| T-Solar Global TS102 T-Solar Global |
102.5 W | Tie (0 W) | 93.0 V | 7.19% | 93.0% |
What Are the Design Limits and Best-Fit Uses for First Solar Inc FS-4102-2?
Evaluate First Solar Inc FS-4102-2 (102.5 W STC, 85.3 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), First Solar Inc FS-4102-2 reaches 95.59 V per panel—exceeding 6 panels in series voids 600 V inverter warranties.
- Footprint constraint: 79 panels for an 8 kW build require 612 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 79 panels (612 sq ft).
- 2026 tax credit baseline: cash residential installs of First Solar Inc FS-4102-2 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
First Solar Inc FS-4102-2 8 kW Residential Fit
Needs 79 modules (612 sq ft) with a 15 A string OCPD, offsetting ~$2,027/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 6 panels (-10 C) or 6 panels (-20 C), or compare Caterpillar Inc PVT112.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 95.0 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for First Solar Inc FS-4102-2 by First Solar Inc grounded in CEC test data and NEC 690.7/690.8 limits.
How many First Solar Inc FS-4102-2 panels fit on a 600 V winter solar string?
At -10 C (14 F), First Solar Inc FS-4102-2 cold Voc rises from 85.3 V to 93.3 V (beta_Voc -0.268%/C), capping a 600 V string at 6 panels (559.8 V).
How much roof area does an 8 kW array of First Solar Inc FS-4102-2 need?
An 8 kW DC system uses 79 First Solar Inc FS-4102-2 modules (8,098 W STC / 7,505 W PTC), covering roughly 612 sq ft and saving ~$2,027/yr at 18.54 c/kWh.
How does First Solar Inc FS-4102-2 compare against Caterpillar Inc PVT112?
First Solar Inc FS-4102-2 outputs 102.5 W STC (85.3 V Voc, rank #21,557 of 21,677), while Caterpillar Inc PVT112 delivers 112.5 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)