Skip to main content
WireAndSun
Calculators
CEC PV Module

First Solar Inc FS-4100A — CEC Solar Module Specifications

Manufacturer: First Solar Inc Registry: CEC Verified Engineering Specification

First Solar Inc FS-4100A is a 100.0 W STC (94.5 W PTC) Thin Film solar module ranking #21,563 of 21,677 CEC listings (below all-CEC median; higher than 0.5% of peers). It delivers 13.89% efficiency, 87.6 V Voc at 25 C, and 95.66 V cold Voc at -10 C (6 panels max per 600 V string).

STC Wattage
100.0 W
PTC Wattage
94.5 W
Voc @ 25C
87.6 V
Efficiency
13.89%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does First Solar Inc FS-4100A Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for First Solar Inc FS-4100A (Thin Film) residential solar systems.

First Solar Inc FS-4100A delivers 138.9 W/m2 (6.02 percentage points below 19.91% CEC median) and strong 94.5% PTC-to-STC heat retention (#2,573 of 21,677), placing it as a compact residential or specialty off-grid module useful on tight dormer roofs or battery cabins, though 8 kW requires 80 panels (620 sq ft). At -4 F (-20 C), string voltage climbs to 97.97 V per unit, capping 600 V circuits at 6 panels. Compare specs directly with Caterpillar Inc PVT112 (112.5 W).

Where Does First Solar Inc FS-4100A Fall Across Listed CEC Models?

Comparison of First Solar Inc FS-4100A (100.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where First Solar Inc FS-4100A (100.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCFirst Solar Inc FS: 100.0 W

What Dataset Percentiles Define First Solar Inc FS-4100A?

Relative ranking of First Solar Inc FS-4100A across nameplate watts, 94.5% PTC thermal ratio, and module aperture efficiency.

First Solar Inc FS-4100A Engineering BenchmarksPercentile comparison of First Solar Inc FS-4100A wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage100.0 WPTC/STC Retention94.5%Module Efficiency13.89%

What Do the Dataset Ranks Show for First Solar Inc FS-4100A?

Summary of First Solar Inc FS-4100A output rank, 8 kW array size (80 panels), efficiency rating, and 600 V string limit.

Rank #21,563 / 21,677

100.0 W STC · Higher Than 0.5%

100.0 W STC (-285.0 W vs all-CEC median) vs 117.5 W Thin Film median.

Eff #20,983

13.89% Aperture Efficiency

Power density 138.9 W/m2 (6.02 percentage points below 19.91% CEC median). PTC/STC ratio: 94.5% (rank #2,573).

NEC 690.7 Limit

6 Panels Max @ -10 C (600 V)

Cold Voc reaches 95.66 V at -10 C (574.0 V string) and 97.97 V at -20 C (6 max).

8 kW Reference Array

80 Panels = 8,000 W STC

Occupies 57.6 m2 (620 sq ft) producing 7,560 W PTC; NEC 690.8 OCPD floor is 2.45 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 87.6 * (1 + (-0.263/100) * (-10 - 25)) = 95.66 V | OCPD = 1.56 * 1.57 = 2.45 A

Inputs from CEC Modules.csv for First Solar Inc FS-4100A: Voc=87.6 V, beta_Voc=-0.263%/C, Isc=1.57 A, STC=100.0 W, Area=0.72 m2.

Result: 6 panels max on 600 V (574.0 V); 80 panels for 8 kW (620 sq ft).

What Are the Published CEC Specifications for First Solar Inc FS-4100A?

Complete CEC test sheet for First Solar Inc FS-4100A including Isc (1.57 A), Voc (87.6 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for First Solar Inc FS-4100A.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 100.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 94.5 W (94.5% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 87.6 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 1.57 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 69.4 V / 1.44 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.263 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 13.89% (0.72 m2) Array roof footprint density
Cell Count & Technology 216 cells (Thin Film) Monofacial backsheet

How Many First Solar Inc FS-4100A Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using First Solar Inc FS-4100A.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 60 6.0 kW 465 sq ft $1,502 $2,539
8 kW Class 80 8.0 kW 620 sq ft $2,002 $3,386
10 kW Class 100 10.0 kW 775 sq ft $2,503 $4,232

How Many First Solar Inc FS-4100A Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for First Solar Inc FS-4100A (87.6 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=87.6V and beta_Voc=-0.263%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 97.97 V 6 panels 587.8 V 10 panels
-10 C (14 F) 95.66 V 6 panels 574.0 V 10 panels
0 C (32 F) 93.36 V 6 panels 560.2 V 10 panels
25 C (77 F STC) 87.6 V 6 panels 525.6 V 11 panels

Which Cross-Brand Solar Modules Compare Closest to First Solar Inc FS-4100A?

Four comparable CEC modules such as Caterpillar Inc PVT112 (112.5 W) for side-by-side solar quote checks. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Caterpillar Inc PVT112
Caterpillar Inc
112.5 W +12.5 W 87.7 V 15.62% 92.9%
Caterpillar Inc PVT112 ARC
Caterpillar Inc
112.5 W +12.5 W 87.7 V 15.62% 92.9%
Toledo Solar Inc TS1
Toledo Solar Inc
115.0 W +15.0 W 87.1 V 15.97% 92.9%
T-Solar Global TS102
T-Solar Global
102.5 W +2.5 W 93.0 V 7.19% 93.0%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for First Solar Inc FS-4100A?

Evaluate First Solar Inc FS-4100A (100.0 W STC, 87.6 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), First Solar Inc FS-4100A reaches 97.97 V per panel—exceeding 6 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 80 panels for an 8 kW build require 620 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 80 panels (620 sq ft).
  • 2026 tax credit baseline: cash residential installs of First Solar Inc FS-4100A carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

First Solar Inc FS-4100A 8 kW Residential Fit

Needs 80 modules (620 sq ft) with a 15 A string OCPD, offsetting ~$2,002/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 6 panels (-10 C) or 6 panels (-20 C), or compare Caterpillar Inc PVT112.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 94.5 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for First Solar Inc FS-4100A by First Solar Inc grounded in CEC test data and NEC 690.7/690.8 limits.

How many First Solar Inc FS-4100A panels fit on a 600 V winter solar string?

At -10 C (14 F), First Solar Inc FS-4100A cold Voc rises from 87.6 V to 95.66 V (beta_Voc -0.263%/C), capping a 600 V string at 6 panels (574.0 V).

How much roof area does an 8 kW array of First Solar Inc FS-4100A need?

An 8 kW DC system uses 80 First Solar Inc FS-4100A modules (8,000 W STC / 7,560 W PTC), covering roughly 620 sq ft and saving ~$2,002/yr at 18.54 c/kWh.

How does First Solar Inc FS-4100A compare against Caterpillar Inc PVT112?

First Solar Inc FS-4100A outputs 100.0 W STC (87.6 V Voc, rank #21,563 of 21,677), while Caterpillar Inc PVT112 delivers 112.5 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.