Manufacturer: First Solar Inc Registry: CEC Verified Engineering Specification

First Solar Inc FS-4100-2 is a 100.0 W STC (92.7 W PTC) Thin Film solar module ranking #21,563 of 21,677 CEC listings (below all-CEC median; higher than 0.5% of peers). It delivers 13.89% efficiency, 84.7 V Voc at 25 C, and 92.64 V cold Voc at -10 C (6 panels max per 600 V string).

STC Wattage
100.0 W
PTC Wattage
92.7 W
Voc @ 25C
84.7 V
Efficiency
13.89%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does First Solar Inc FS-4100-2 Compare Against Peer CEC Listings?

Engineering position of First Solar Inc FS-4100-2 (100.0 W STC) vs. Caterpillar Inc PVT112 across 106 CEC Thin Film solar modules.

Built with 216 Thin Film cells, First Solar Inc FS-4100-2 pairs strong 92.7% PTC-to-STC heat retention (#11,468 of 21,677) with 84.7 V nominal Voc. An 8 kW residential build (8,000 W DC, 7,416 W PTC) saves ~$2,002/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer Caterpillar Inc PVT112 offers a 112.5 W alternative.

Where Does First Solar Inc FS-4100-2 Fall Across Listed CEC Models?

Plots First Solar Inc FS-4100-2 at 100.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where First Solar Inc FS-4100-2 (100.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCFirst Solar Inc FS: 100.0 W

What Dataset Percentiles Define First Solar Inc FS-4100-2?

Benchmarks First Solar Inc FS-4100-2 on STC wattage, thermal PTC/STC retention, and 13.89 aperture conversion efficiency against CEC peers.

First Solar Inc FS-4100-2 Engineering BenchmarksPercentile comparison of First Solar Inc FS-4100-2 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage100.0 WPTC/STC Retention92.7%Module Efficiency13.89%

What Do the Dataset Ranks Show for First Solar Inc FS-4100-2?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for First Solar Inc FS-4100-2 by First Solar Inc.

Rank #21,563 / 21,677

100.0 W STC · Higher Than 0.5%

100.0 W STC (-285.0 W vs all-CEC median) vs 117.5 W Thin Film median.

Eff #20,983

13.89% Aperture Efficiency

Power density 138.9 W/m2 (6.02 percentage points below 19.91% CEC median). PTC/STC ratio: 92.7% (rank #11,468).

NEC 690.7 Limit

6 Panels Max @ -10 C (600 V)

Cold Voc reaches 92.64 V at -10 C (555.8 V string) and 94.91 V at -20 C (6 max).

8 kW Reference Array

80 Panels = 8,000 W STC

Occupies 57.6 m2 (620 sq ft) producing 7,416 W PTC; NEC 690.8 OCPD floor is 2.7 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 84.7 * (1 + (-0.268/100) * (-10 - 25)) = 92.64 V | OCPD = 1.56 * 1.73 = 2.7 A

Inputs from CEC Modules.csv for First Solar Inc FS-4100-2: Voc=84.7 V, beta_Voc=-0.268%/C, Isc=1.73 A, STC=100.0 W, Area=0.72 m2.

Result: 6 panels max on 600 V (555.8 V); 80 panels for 8 kW (620 sq ft).

What Are the Published CEC Specifications for First Solar Inc FS-4100-2?

Laboratory test ratings recorded for First Solar Inc FS-4100-2 (Thin Film) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for First Solar Inc FS-4100-2.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 100.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 92.7 W (92.7% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 84.7 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 1.73 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 66.2 V / 1.51 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.268 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 13.89% (0.72 m2) Array roof footprint density
Cell Count & Technology 216 cells (Thin Film) Monofacial backsheet

How Many First Solar Inc FS-4100-2 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (620 sq ft at 8 kW), and estimated Year-1 electric bill offset for First Solar Inc FS-4100-2.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 60 6.0 kW 465 sq ft $1,502 $2,539
8 kW Class 80 8.0 kW 620 sq ft $2,002 $3,386
10 kW Class 100 10.0 kW 775 sq ft $2,503 $4,232

How Many First Solar Inc FS-4100-2 Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for First Solar Inc FS-4100-2 (beta_Voc -0.268%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=84.7V and beta_Voc=-0.268%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 94.91 V 6 panels 569.5 V 10 panels
-10 C (14 F) 92.64 V 6 panels 555.8 V 10 panels
0 C (32 F) 90.37 V 6 panels 542.2 V 11 panels
25 C (77 F STC) 84.7 V 7 panels 592.9 V 11 panels

Which Cross-Brand Solar Modules Compare Closest to First Solar Inc FS-4100-2?

Closest cross-brand CEC competitors to First Solar Inc FS-4100-2 matched near 100.0 W STC and 84.7 V Voc, led by Caterpillar Inc PVT112.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Caterpillar Inc PVT112
Caterpillar Inc
112.5 W +12.5 W 87.7 V 15.62% 92.9%
Caterpillar Inc PVT112 ARC
Caterpillar Inc
112.5 W +12.5 W 87.7 V 15.62% 92.9%
Toledo Solar Inc TS1
Toledo Solar Inc
115.0 W +15.0 W 87.1 V 15.97% 92.9%
T-Solar Global TS102
T-Solar Global
102.5 W +2.5 W 93.0 V 7.19% 93.0%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for First Solar Inc FS-4100-2?

Evaluate First Solar Inc FS-4100-2 (100.0 W STC, 84.7 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), First Solar Inc FS-4100-2 reaches 94.91 V per panel—exceeding 6 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 80 panels for an 8 kW build require 620 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 80 panels (620 sq ft).
  • 2026 tax credit baseline: cash residential installs of First Solar Inc FS-4100-2 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

First Solar Inc FS-4100-2 8 kW Residential Fit

Needs 80 modules (620 sq ft) with a 15 A string OCPD, offsetting ~$2,002/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 6 panels (-10 C) or 6 panels (-20 C), or compare Caterpillar Inc PVT112.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 92.7 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for First Solar Inc FS-4100-2 by First Solar Inc grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for First Solar Inc FS-4100-2?

Multiplying First Solar Inc FS-4100-2's 1.73 A short-circuit current by 1.56 equals 2.7 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

Can First Solar Inc FS-4100-2 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 92.64 V cold Voc at 14 F and handles 1.73 A Isc; string inverters cap First Solar Inc FS-4100-2 at 6 panels on 600 V.

Is First Solar Inc FS-4100-2 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of First Solar Inc FS-4100-2 rely on utility bill offset (~$2,002/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.