First Solar Inc FS-4100-2 is a 100.0 W STC (92.7 W PTC) Thin Film solar module ranking #21,563 of 21,677 CEC listings (below all-CEC median; higher than 0.5% of peers). It delivers 13.89% efficiency, 84.7 V Voc at 25 C, and 92.64 V cold Voc at -10 C (6 panels max per 600 V string).
- STC Wattage
- 100.0 W
- PTC Wattage
- 92.7 W
- Voc @ 25C
- 84.7 V
- Efficiency
- 13.89%
How Does First Solar Inc FS-4100-2 Compare Against Peer CEC Listings?
Engineering position of First Solar Inc FS-4100-2 (100.0 W STC) vs. Caterpillar Inc PVT112 across 106 CEC Thin Film solar modules.
Built with 216 Thin Film cells, First Solar Inc FS-4100-2 pairs strong 92.7% PTC-to-STC heat retention (#11,468 of 21,677) with 84.7 V nominal Voc. An 8 kW residential build (8,000 W DC, 7,416 W PTC) saves ~$2,002/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer Caterpillar Inc PVT112 offers a 112.5 W alternative.
Where Does First Solar Inc FS-4100-2 Fall Across Listed CEC Models?
Plots First Solar Inc FS-4100-2 at 100.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.
What Dataset Percentiles Define First Solar Inc FS-4100-2?
Benchmarks First Solar Inc FS-4100-2 on STC wattage, thermal PTC/STC retention, and 13.89 aperture conversion efficiency against CEC peers.
What Do the Dataset Ranks Show for First Solar Inc FS-4100-2?
Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for First Solar Inc FS-4100-2 by First Solar Inc.
100.0 W STC · Higher Than 0.5%
100.0 W STC (-285.0 W vs all-CEC median) vs 117.5 W Thin Film median.
13.89% Aperture Efficiency
Power density 138.9 W/m2 (6.02 percentage points below 19.91% CEC median). PTC/STC ratio: 92.7% (rank #11,468).
6 Panels Max @ -10 C (600 V)
Cold Voc reaches 92.64 V at -10 C (555.8 V string) and 94.91 V at -20 C (6 max).
80 Panels = 8,000 W STC
Occupies 57.6 m2 (620 sq ft) producing 7,416 W PTC; NEC 690.8 OCPD floor is 2.7 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 84.7 * (1 + (-0.268/100) * (-10 - 25)) = 92.64 V | OCPD = 1.56 * 1.73 = 2.7 A
Inputs from CEC Modules.csv for First Solar Inc FS-4100-2: Voc=84.7 V, beta_Voc=-0.268%/C, Isc=1.73 A, STC=100.0 W, Area=0.72 m2.
Result: 6 panels max on 600 V (555.8 V); 80 panels for 8 kW (620 sq ft).
What Are the Published CEC Specifications for First Solar Inc FS-4100-2?
Laboratory test ratings recorded for First Solar Inc FS-4100-2 (Thin Film) in the official California Energy Commission NREL SAM equipment catalog.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 100.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 92.7 W (92.7% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 84.7 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 1.73 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 66.2 V / 1.51 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.268 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 13.89% (0.72 m2) | Array roof footprint density |
| Cell Count & Technology | 216 cells (Thin Film) | Monofacial backsheet |
How Many First Solar Inc FS-4100-2 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Panel counts, roof square footage (620 sq ft at 8 kW), and estimated Year-1 electric bill offset for First Solar Inc FS-4100-2.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 60 | 6.0 kW | 465 sq ft | $1,502 | $2,539 |
| 8 kW Class | 80 | 8.0 kW | 620 sq ft | $2,002 | $3,386 |
| 10 kW Class | 100 | 10.0 kW | 775 sq ft | $2,503 | $4,232 |
How Many First Solar Inc FS-4100-2 Modules Fit in a Cold-Weather String?
Cold-weather Voc escalation for First Solar Inc FS-4100-2 (beta_Voc -0.268%/C) across 600 V residential and 1,000 V commercial inverters.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 94.91 V | 6 panels | 569.5 V | 10 panels |
| -10 C (14 F) | 92.64 V | 6 panels | 555.8 V | 10 panels |
| 0 C (32 F) | 90.37 V | 6 panels | 542.2 V | 11 panels |
| 25 C (77 F STC) | 84.7 V | 7 panels | 592.9 V | 11 panels |
Which Cross-Brand Solar Modules Compare Closest to First Solar Inc FS-4100-2?
Closest cross-brand CEC competitors to First Solar Inc FS-4100-2 matched near 100.0 W STC and 84.7 V Voc, led by Caterpillar Inc PVT112.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Caterpillar Inc PVT112 Caterpillar Inc |
112.5 W | +12.5 W | 87.7 V | 15.62% | 92.9% |
| Caterpillar Inc PVT112 ARC Caterpillar Inc |
112.5 W | +12.5 W | 87.7 V | 15.62% | 92.9% |
| Toledo Solar Inc TS1 Toledo Solar Inc |
115.0 W | +15.0 W | 87.1 V | 15.97% | 92.9% |
| T-Solar Global TS102 T-Solar Global |
102.5 W | +2.5 W | 93.0 V | 7.19% | 93.0% |
What Are the Design Limits and Best-Fit Uses for First Solar Inc FS-4100-2?
Evaluate First Solar Inc FS-4100-2 (100.0 W STC, 84.7 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), First Solar Inc FS-4100-2 reaches 94.91 V per panel—exceeding 6 panels in series voids 600 V inverter warranties.
- Footprint constraint: 80 panels for an 8 kW build require 620 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 80 panels (620 sq ft).
- 2026 tax credit baseline: cash residential installs of First Solar Inc FS-4100-2 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
First Solar Inc FS-4100-2 8 kW Residential Fit
Needs 80 modules (620 sq ft) with a 15 A string OCPD, offsetting ~$2,002/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 6 panels (-10 C) or 6 panels (-20 C), or compare Caterpillar Inc PVT112.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 92.7 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for First Solar Inc FS-4100-2 by First Solar Inc grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for First Solar Inc FS-4100-2?
Multiplying First Solar Inc FS-4100-2's 1.73 A short-circuit current by 1.56 equals 2.7 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.
Can First Solar Inc FS-4100-2 pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 92.64 V cold Voc at 14 F and handles 1.73 A Isc; string inverters cap First Solar Inc FS-4100-2 at 6 panels on 600 V.
Is First Solar Inc FS-4100-2 eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of First Solar Inc FS-4100-2 rely on utility bill offset (~$2,002/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)