First Solar Inc FS-270 is a 70.0 W STC (67.2 W PTC) Thin Film solar module ranking #21,637 of 21,677 CEC listings (below all-CEC median; higher than 0.2% of peers). It delivers 9.72% efficiency, 89.0 V Voc at 25 C, and 96.85 V cold Voc at -10 C (6 panels max per 600 V string).
- STC Wattage
- 70.0 W
- PTC Wattage
- 67.2 W
- Voc @ 25C
- 89.0 V
- Efficiency
- 9.72%
How Does First Solar Inc FS-270 Compare Against Peer CEC Listings?
How First Solar Inc First Solar Inc FS-270 handles rooftop heat (67.2 W PTC), 8 kW sizing, and cold winter string voltage.
First Solar Inc builds the First Solar Inc FS-270 (Thin Film) as a compact residential or specialty off-grid module delivering 97.2 W/m2 (10.19 percentage points below 19.91% CEC median). Compared against T-Solar Global TS97 (97.5 W), this model holds strong 96.0% PTC-to-STC heat retention (#21 of 21,677). Higher 89.0 V open-circuit voltage caps 600 V residential strings at 6 panels at 14 F (-10 C), while NEC 690.8 sets a 1.86 A overcurrent floor served by a 15 A breaker.
Where Does First Solar Inc FS-270 Fall Across Listed CEC Models?
Where First Solar Inc FS-270 (70.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define First Solar Inc FS-270?
Percentile placement of First Solar Inc FS-270 across power density (97.2 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for First Solar Inc FS-270?
Four critical engineering numbers homeowners and solar installers check first when reviewing First Solar Inc FS-270 specifications. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.
70.0 W STC · Higher Than 0.2%
70.0 W STC (-315.0 W vs all-CEC median) vs 117.5 W Thin Film median.
9.72% Aperture Efficiency
Power density 97.2 W/m2 (10.19 percentage points below 19.91% CEC median). PTC/STC ratio: 96.0% (rank #21).
6 Panels Max @ -10 C (600 V)
Cold Voc reaches 96.85 V at -10 C (581.1 V string) and 99.09 V at -20 C (6 max).
115 Panels = 8,050 W STC
Occupies 82.8 m2 (891 sq ft) producing 7,728 W PTC; NEC 690.8 OCPD floor is 1.86 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 89.0 * (1 + (-0.252/100) * (-10 - 25)) = 96.85 V | OCPD = 1.56 * 1.19 = 1.86 A
Inputs from CEC Modules.csv for First Solar Inc FS-270: Voc=89.0 V, beta_Voc=-0.252%/C, Isc=1.19 A, STC=70.0 W, Area=0.72 m2.
Result: 6 panels max on 600 V (581.1 V); 115 panels for 8 kW (891 sq ft).
What Are the Published CEC Specifications for First Solar Inc FS-270?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for First Solar Inc FS-270.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 70.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 67.2 W (96.0% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 89.0 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 1.19 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 67.9 V / 1.07 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.252 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 9.72% (0.72 m2) | Array roof footprint density |
| Cell Count & Technology | 116 cells (Thin Film) | Monofacial backsheet |
How Many First Solar Inc FS-270 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using First Solar Inc FS-270 (70.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 86 | 6.02 kW | 667 sq ft | $1,507 | $2,548 |
| 8 kW Class | 115 | 8.05 kW | 891 sq ft | $2,015 | $3,407 |
| 10 kW Class | 143 | 10.01 kW | 1,108 sq ft | $2,505 | $4,236 |
Which Sibling Wattage & Trim Variants Belong to This First Solar Inc Series?
All closely matched First Solar Inc wattages and cosmetic trims sharing the First Solar Inc FS-270 architecture. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| First Solar Inc FS-267 | 67.5 W | 64.8 W | 87.0 V | 64.2 V | 9.38% |
| First Solar Inc FS-270 | 70.0 W | 67.2 W | 89.0 V | 67.9 V | 9.72% |
| First Solar Inc FS-272 | 72.5 W | 69.8 W | 90.0 V | 67.9 V | 10.07% |
How Many First Solar Inc FS-270 Modules Fit in a Cold-Weather String?
Maximum series module counts for First Solar Inc FS-270 from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 99.09 V | 6 panels | 594.5 V | 10 panels |
| -10 C (14 F) | 96.85 V | 6 panels | 581.1 V | 10 panels |
| 0 C (32 F) | 94.61 V | 6 panels | 567.7 V | 10 panels |
| 25 C (77 F STC) | 89.0 V | 6 panels | 534.0 V | 11 panels |
Which Cross-Brand Solar Modules Compare Closest to First Solar Inc FS-270?
Alternative CEC solar modules from competing brands near First Solar Inc FS-270 (70.0 W), including T-Solar Global TS97.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| T-Solar Global TS97 T-Solar Global |
97.5 W | +27.5 W | 93.0 V | 6.84% | 92.9% |
| Caterpillar Inc PVT112 Caterpillar Inc |
112.5 W | +42.5 W | 87.7 V | 15.62% | 92.9% |
| Caterpillar Inc PVT112 ARC Caterpillar Inc |
112.5 W | +42.5 W | 87.7 V | 15.62% | 92.9% |
| T-Solar Global TS102 T-Solar Global |
102.5 W | +32.5 W | 93.0 V | 7.19% | 93.0% |
What Are the Design Limits and Best-Fit Uses for First Solar Inc FS-270?
Evaluate First Solar Inc FS-270 (70.0 W STC, 89.0 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), First Solar Inc FS-270 reaches 99.09 V per panel—exceeding 6 panels in series voids 600 V inverter warranties.
- Footprint constraint: 115 panels for an 8 kW build require 891 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 115 panels (891 sq ft).
- 2026 tax credit baseline: cash residential installs of First Solar Inc FS-270 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
First Solar Inc FS-270 8 kW Residential Fit
Needs 115 modules (891 sq ft) with a 15 A string OCPD, offsetting ~$2,015/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 6 panels (-10 C) or 6 panels (-20 C), or compare T-Solar Global TS97.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 67.2 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for First Solar Inc FS-270 by First Solar Inc grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for First Solar Inc FS-270?
Multiplying First Solar Inc FS-270's 1.19 A short-circuit current by 1.56 equals 1.86 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.
Can First Solar Inc FS-270 pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 96.85 V cold Voc at 14 F and handles 1.19 A Isc; string inverters cap First Solar Inc FS-270 at 6 panels on 600 V.
Is First Solar Inc FS-270 eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of First Solar Inc FS-270 rely on utility bill offset (~$2,015/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)