Chint New Energy Technology Co Ltd CHSM66M(DG)/F-BH-675 is a 675.0 W STC (627.2 W PTC) Mono-c-Si solar module ranking #311 of 21,677 CEC listings (top 1.6%; higher than 98.4% of peers). It delivers 22.28% efficiency, 46.49 V Voc at 25 C, and 51.23 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 675.0 W
- PTC Wattage
- 627.2 W
- Voc @ 25C
- 46.49 V
- Efficiency
- 22.28%
How Does Chint New Energy Technology Co Ltd CHSM66M(DG)/F-BH-675 Compare Against Peer CEC Listings?
Solar engineering breakdown for Chint New Energy Technology Co Ltd CHSM66M(DG)/F-BH-675: PTC thermal retention, roof footprint, and cold Voc string bounds.
Across 5,889 Mono-c-Si listings from Chint New Energy Technology Co Ltd and peers, Chint New Energy Technology Co Ltd CHSM66M(DG)/F-BH-675 stands 265.0 W above the 410.0 W Mono-c-Si median and strong 92.9% PTC-to-STC heat retention (#10,348 of 21,677). Sizing 6 kW (9 panels) to 10 kW (15 panels) yields $1,522-$2,533/yr in baseline US bill offset. Mid-range 46.49 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F.
Where Does Chint New Energy Technology Co Ltd CHSM66M(DG)/F-BH-675 Fall Across Listed CEC Models?
Distribution marker showing Chint New Energy Technology Co Ltd CHSM66M(DG)/F-BH-675 (675.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define Chint New Energy Technology Co Ltd CHSM66M(DG)/F-BH-675?
Dataset percentiles tracking Chint New Energy Technology Co Ltd CHSM66M(DG)/F-BH-675 power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for Chint New Energy Technology Co Ltd CHSM66M(DG)/F-BH-675?
Benchmark highlights for Chint New Energy Technology Co Ltd CHSM66M(DG)/F-BH-675 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
Top 1.6% STC Output
675.0 W STC (+290.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
22.28% Aperture Efficiency
Power density 222.8 W/m2 (2.37 percentage points above 19.91% CEC median). PTC/STC ratio: 92.9% (rank #10,348).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 51.23 V at -10 C (563.5 V string) and 52.58 V at -20 C (11 max).
12 Panels = 8,100 W STC
Occupies 36.4 m2 (391 sq ft) producing 7,526 W PTC; NEC 690.8 OCPD floor is 28.97 A (30 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 46.49 * (1 + (-0.291/100) * (-10 - 25)) = 51.23 V | OCPD = 1.56 * 18.57 = 28.97 A
Inputs from CEC Modules.csv for Chint New Energy Technology Co Ltd CHSM66M(DG)/F-BH-675: Voc=46.49 V, beta_Voc=-0.291%/C, Isc=18.57 A, STC=675.0 W, Area=3.03 m2.
Result: 11 panels max on 600 V (563.5 V); 12 panels for 8 kW (391 sq ft).
What Are the Published CEC Specifications for Chint New Energy Technology Co Ltd CHSM66M(DG)/F-BH-675?
Official CEC datasheet figures for Chint New Energy Technology Co Ltd CHSM66M(DG)/F-BH-675 (Mono-c-Si) used in utility interconnection and permit reviews.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 675.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 627.2 W (92.9% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 46.49 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 18.57 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 38.68 V / 17.46 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.291 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 22.28% (3.03 m2) | Array roof footprint density |
| Cell Count & Technology | 66 cells (Mono-c-Si) | Bifacial glass-glass |
How Many Chint New Energy Technology Co Ltd CHSM66M(DG)/F-BH-675 Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many Chint New Energy Technology Co Ltd CHSM66M(DG)/F-BH-675 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 9 | 6.08 kW | 294 sq ft | $1,522 | $2,573 |
| 8 kW Class | 12 | 8.1 kW | 391 sq ft | $2,027 | $3,428 |
| 10 kW Class | 15 | 10.12 kW | 489 sq ft | $2,533 | $4,283 |
How Many Chint New Energy Technology Co Ltd CHSM66M(DG)/F-BH-675 Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on Chint New Energy Technology Co Ltd CHSM66M(DG)/F-BH-675 (51.23 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 52.58 V | 11 panels | 578.4 V | 19 panels |
| -10 C (14 F) | 51.23 V | 11 panels | 563.5 V | 19 panels |
| 0 C (32 F) | 49.87 V | 12 panels | 598.4 V | 20 panels |
| 25 C (77 F STC) | 46.49 V | 12 panels | 557.9 V | 21 panels |
Which Cross-Brand Solar Modules Compare Closest to Chint New Energy Technology Co Ltd CHSM66M(DG)/F-BH-675?
Competing CEC solar panels closest to Chint New Energy Technology Co Ltd CHSM66M(DG)/F-BH-675 in nameplate wattage and Voc, starting with Topsun Co Ltd TOP CLASS 675CH12.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Topsun Co Ltd TOP CLASS 675CH12 Topsun Co Ltd |
675.0 W | Tie (0 W) | 46.49 V | 22.28% | 92.9% |
| SUNPLUS OPTIMUM LIMITED SR5-66HBD-675M SUNPLUS OPTIMUM LIMITED |
675.0 W | Tie (0 W) | 46.5 V | 22.28% | 92.9% |
| CW ENERJ M HEND SL K T CARET VE SANAY ANON M RKET CWT675-132PMB12 CW ENERJ M HEND SL K T CARET VE SANAY ANON M RKET |
675.0 W | Tie (0 W) | 46.2 V | 21.7% | 93.7% |
| Qcells North America QPEAK DUO ML-G12S3/BFG 675 Qcells North America |
675.0 W | Tie (0 W) | 45.74 V | 22.28% | 94.1% |
What Are the Design Limits and Best-Fit Uses for Chint New Energy Technology Co Ltd CHSM66M(DG)/F-BH-675?
Evaluate Chint New Energy Technology Co Ltd CHSM66M(DG)/F-BH-675 (675.0 W STC, 46.49 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Chint New Energy Technology Co Ltd CHSM66M(DG)/F-BH-675 reaches 52.58 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 12 panels for an 8 kW build require 391 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of Chint New Energy Technology Co Ltd CHSM66M(DG)/F-BH-675 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Chint New Energy Technology Co Ltd CHSM66M(DG)/F-BH-675 8 kW Residential Fit
Needs 12 modules (391 sq ft) with a 30 A string OCPD, offsetting ~$2,027/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Topsun Co Ltd TOP CLASS 675CH12.
Bifacial / High-Heat Roof Check
Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 627.2 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Chint New Energy Technology Co Ltd CHSM66M(DG)/F-BH-675 by Chint New Energy Technology Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Chint New Energy Technology Co Ltd CHSM66M(DG)/F-BH-675?
Multiplying Chint New Energy Technology Co Ltd CHSM66M(DG)/F-BH-675's 18.57 A short-circuit current by 1.56 equals 28.97 A minimum ampacity, requiring at least a 30 A overcurrent fuse or breaker.
Can Chint New Energy Technology Co Ltd CHSM66M(DG)/F-BH-675 pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 51.23 V cold Voc at 14 F and handles 18.57 A Isc; string inverters cap Chint New Energy Technology Co Ltd CHSM66M(DG)/F-BH-675 at 11 panels on 600 V.
Is Chint New Energy Technology Co Ltd CHSM66M(DG)/F-BH-675 eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Chint New Energy Technology Co Ltd CHSM66M(DG)/F-BH-675 rely on utility bill offset (~$2,027/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)