Chint New Energy Technology Co Ltd CHSM66N(DG)/F-BH-710 is a 710.0 W STC (673.3 W PTC) Mono-c-Si solar module ranking #135 of 21,677 CEC listings (top 0.8%; higher than 99.2% of peers). It delivers 22.83% efficiency, 48.77 V Voc at 25 C, and 53.36 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 710.0 W
- PTC Wattage
- 673.3 W
- Voc @ 25C
- 48.77 V
- Efficiency
- 22.83%
How Does Chint New Energy Technology Co Ltd CHSM66N(DG)/F-BH-710 Compare Against Peer CEC Listings?
CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Chint New Energy Technology Co Ltd CHSM66N(DG)/F-BH-710 (Mono-c-Si) residential solar systems.
Chint New Energy Technology Co Ltd CHSM66N(DG)/F-BH-710 delivers 228.3 W/m2 (2.92 percentage points above 19.91% CEC median) and strong 94.8% PTC-to-STC heat retention (#1,790 of 21,677), placing it as a large-format commercial and ground-mount module better matched to wide open ground racks or commercial flat roofs than tight residential roof hips. At -4 F (-20 C), string voltage climbs to 54.67 V per unit, capping 600 V circuits at 10 panels. Compare specs directly with Nuuko Solar GmbH NKM710N-132BDG12 (710.0 W).
Where Does Chint New Energy Technology Co Ltd CHSM66N(DG)/F-BH-710 Fall Across Listed CEC Models?
Comparison of Chint New Energy Technology Co Ltd CHSM66N(DG)/F-BH-710 (710.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.
What Dataset Percentiles Define Chint New Energy Technology Co Ltd CHSM66N(DG)/F-BH-710?
Relative ranking of Chint New Energy Technology Co Ltd CHSM66N(DG)/F-BH-710 across nameplate watts, 94.8% PTC thermal ratio, and module aperture efficiency.
What Do the Dataset Ranks Show for Chint New Energy Technology Co Ltd CHSM66N(DG)/F-BH-710?
Summary of Chint New Energy Technology Co Ltd CHSM66N(DG)/F-BH-710 output rank, 8 kW array size (12 panels), efficiency rating, and 600 V string limit.
Top 0.8% STC Output
710.0 W STC (+325.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
22.83% Aperture Efficiency
Power density 228.3 W/m2 (2.92 percentage points above 19.91% CEC median). PTC/STC ratio: 94.8% (rank #1,790).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 53.36 V at -10 C (587.0 V string) and 54.67 V at -20 C (10 max).
12 Panels = 8,520 W STC
Occupies 37.3 m2 (402 sq ft) producing 8,080 W PTC; NEC 690.8 OCPD floor is 28.83 A (30 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 48.77 * (1 + (-0.269/100) * (-10 - 25)) = 53.36 V | OCPD = 1.56 * 18.48 = 28.83 A
Inputs from CEC Modules.csv for Chint New Energy Technology Co Ltd CHSM66N(DG)/F-BH-710: Voc=48.77 V, beta_Voc=-0.269%/C, Isc=18.48 A, STC=710.0 W, Area=3.11 m2.
Result: 11 panels max on 600 V (587.0 V); 12 panels for 8 kW (402 sq ft).
What Are the Published CEC Specifications for Chint New Energy Technology Co Ltd CHSM66N(DG)/F-BH-710?
Complete CEC test sheet for Chint New Energy Technology Co Ltd CHSM66N(DG)/F-BH-710 including Isc (18.48 A), Voc (48.77 V), and thermal temperature coefficients.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 710.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 673.3 W (94.8% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 48.77 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 18.48 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 40.48 V / 17.54 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.269 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 22.83% (3.11 m2) | Array roof footprint density |
| Cell Count & Technology | 66 cells (Mono-c-Si) | Bifacial glass-glass |
How Many Chint New Energy Technology Co Ltd CHSM66N(DG)/F-BH-710 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Chint New Energy Technology Co Ltd CHSM66N(DG)/F-BH-710.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 9 | 6.39 kW | 301 sq ft | $1,599 | $2,704 |
| 8 kW Class | 12 | 8.52 kW | 402 sq ft | $2,132 | $3,606 |
| 10 kW Class | 15 | 10.65 kW | 502 sq ft | $2,666 | $4,507 |
Which Sibling Wattage & Trim Variants Belong to This Chint New Energy Technology Co Ltd Series?
Related Chint New Energy Technology Co Ltd power steps and black/silver trims consolidated into this Chint New Energy Technology Co Ltd CHSM66N(DG)/F-BH-710 series guide.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Chint New Energy Technology Co Ltd CHSM66N(DG)/F-BH-700 | 700.0 W | 663.6 W | 48.37 V | 40.15 V | 22.51% |
| Chint New Energy Technology Co Ltd CHSM66N(DG)/F-BH-705 | 705.0 W | 668.4 W | 48.57 V | 40.31 V | 22.67% |
| Chint New Energy Technology Co Ltd CHSM66N(DG)/F-BH-710 | 710.0 W | 673.3 W | 48.77 V | 40.48 V | 22.83% |
| Chint New Energy Technology Co Ltd CHSM66N(DG)/F-BH-715 | 715.0 W | 678.1 W | 48.97 V | 40.65 V | 22.99% |
| Chint New Energy Technology Co Ltd CHSM66N(DG)/F-BH-720 | 720.0 W | 683.0 W | 49.17 V | 40.81 V | 23.15% |
How Many Chint New Energy Technology Co Ltd CHSM66N(DG)/F-BH-710 Modules Fit in a Cold-Weather String?
Verify freezing-morning voltage rise for Chint New Energy Technology Co Ltd CHSM66N(DG)/F-BH-710 (48.77 V STC) before wiring 600 V or 1,000 V strings.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 54.67 V | 10 panels | 546.7 V | 18 panels |
| -10 C (14 F) | 53.36 V | 11 panels | 587.0 V | 18 panels |
| 0 C (32 F) | 52.05 V | 11 panels | 572.5 V | 19 panels |
| 25 C (77 F STC) | 48.77 V | 12 panels | 585.2 V | 20 panels |
Which Cross-Brand Solar Modules Compare Closest to Chint New Energy Technology Co Ltd CHSM66N(DG)/F-BH-710?
Four comparable CEC modules such as Nuuko Solar GmbH NKM710N-132BDG12 (710.0 W) for side-by-side solar quote checks. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Nuuko Solar GmbH NKM710N-132BDG12 Nuuko Solar GmbH |
710.0 W | Tie (0 W) | 48.73 V | 22.83% | 94.3% |
| ZNSHINE PV-TECH Co Ltd ZXM8-GPLDD132-710/N ZNSHINE PV-TECH Co Ltd |
710.0 W | Tie (0 W) | 48.7 V | 22.9% | 95.6% |
| SEG Solar Inc SEG-710-BTC-BG SEG Solar Inc |
710.0 W | Tie (0 W) | 48.87 V | 23.43% | 95.7% |
| Vietnam Sunergy Joint Stock Company VSUN710N-132BMH-DG Vietnam Sunergy Joint Stock Company |
710.0 W | Tie (0 W) | 48.9 V | 22.86% | 94.4% |
What Are the Design Limits and Best-Fit Uses for Chint New Energy Technology Co Ltd CHSM66N(DG)/F-BH-710?
Evaluate Chint New Energy Technology Co Ltd CHSM66N(DG)/F-BH-710 (710.0 W STC, 48.77 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Chint New Energy Technology Co Ltd CHSM66N(DG)/F-BH-710 reaches 54.67 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 12 panels for an 8 kW build require 402 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of Chint New Energy Technology Co Ltd CHSM66N(DG)/F-BH-710 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Chint New Energy Technology Co Ltd CHSM66N(DG)/F-BH-710 8 kW Residential Fit
Needs 12 modules (402 sq ft) with a 30 A string OCPD, offsetting ~$2,132/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare Nuuko Solar GmbH NKM710N-132BDG12.
Bifacial / High-Heat Roof Check
Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 673.3 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Chint New Energy Technology Co Ltd CHSM66N(DG)/F-BH-710 by Chint New Energy Technology Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
How many Chint New Energy Technology Co Ltd CHSM66N(DG)/F-BH-710 panels fit on a 600 V winter solar string?
At -10 C (14 F), Chint New Energy Technology Co Ltd CHSM66N(DG)/F-BH-710 cold Voc rises from 48.77 V to 53.36 V (beta_Voc -0.269%/C), capping a 600 V string at 11 panels (587.0 V).
How much roof area does an 8 kW array of Chint New Energy Technology Co Ltd CHSM66N(DG)/F-BH-710 need?
An 8 kW DC system uses 12 Chint New Energy Technology Co Ltd CHSM66N(DG)/F-BH-710 modules (8,520 W STC / 8,080 W PTC), covering roughly 402 sq ft and saving ~$2,132/yr at 18.54 c/kWh.
How does Chint New Energy Technology Co Ltd CHSM66N(DG)/F-BH-710 compare against Nuuko Solar GmbH NKM710N-132BDG12?
Chint New Energy Technology Co Ltd CHSM66N(DG)/F-BH-710 outputs 710.0 W STC (48.77 V Voc, rank #135 of 21,677), while Nuuko Solar GmbH NKM710N-132BDG12 delivers 710.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)