Chint New Energy Technology Co Ltd CHSM66N(DG)/F-BH-685 is a 685.0 W STC (649.0 W PTC) Mono-c-Si solar module ranking #272 of 21,677 CEC listings (top 1.3%; higher than 98.7% of peers). It delivers 22.03% efficiency, 47.77 V Voc at 25 C, and 52.27 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 685.0 W
- PTC Wattage
- 649.0 W
- Voc @ 25C
- 47.77 V
- Efficiency
- 22.03%
How Does Chint New Energy Technology Co Ltd CHSM66N(DG)/F-BH-685 Compare Against Peer CEC Listings?
How Chint New Energy Technology Co Ltd Chint New Energy Technology Co Ltd CHSM66N(DG)/F-BH-685 handles rooftop heat (649.0 W PTC), 8 kW sizing, and cold winter string voltage.
Chint New Energy Technology Co Ltd builds the Chint New Energy Technology Co Ltd CHSM66N(DG)/F-BH-685 (Mono-c-Si) as a large-format commercial and ground-mount module delivering 220.3 W/m2 (2.12 percentage points above 19.91% CEC median). Compared against SUNPLUS OPTIMUM LIMITED SR5-66NHBD-685M (685.0 W), this model holds strong 94.7% PTC-to-STC heat retention (#2,085 of 21,677). Mid-range 47.77 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F, while NEC 690.8 sets a 28.44 A overcurrent floor served by a 30 A breaker.
Where Does Chint New Energy Technology Co Ltd CHSM66N(DG)/F-BH-685 Fall Across Listed CEC Models?
Where Chint New Energy Technology Co Ltd CHSM66N(DG)/F-BH-685 (685.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define Chint New Energy Technology Co Ltd CHSM66N(DG)/F-BH-685?
Percentile placement of Chint New Energy Technology Co Ltd CHSM66N(DG)/F-BH-685 across power density (220.3 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for Chint New Energy Technology Co Ltd CHSM66N(DG)/F-BH-685?
Four critical engineering numbers homeowners and solar installers check first when reviewing Chint New Energy Technology Co Ltd CHSM66N(DG)/F-BH-685 specifications.
Top 1.3% STC Output
685.0 W STC (+300.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
22.03% Aperture Efficiency
Power density 220.3 W/m2 (2.12 percentage points above 19.91% CEC median). PTC/STC ratio: 94.7% (rank #2,085).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 52.27 V at -10 C (575.0 V string) and 53.55 V at -20 C (11 max).
12 Panels = 8,220 W STC
Occupies 37.3 m2 (402 sq ft) producing 7,788 W PTC; NEC 690.8 OCPD floor is 28.44 A (30 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 47.77 * (1 + (-0.269/100) * (-10 - 25)) = 52.27 V | OCPD = 1.56 * 18.23 = 28.44 A
Inputs from CEC Modules.csv for Chint New Energy Technology Co Ltd CHSM66N(DG)/F-BH-685: Voc=47.77 V, beta_Voc=-0.269%/C, Isc=18.23 A, STC=685.0 W, Area=3.11 m2.
Result: 11 panels max on 600 V (575.0 V); 12 panels for 8 kW (402 sq ft).
What Are the Published CEC Specifications for Chint New Energy Technology Co Ltd CHSM66N(DG)/F-BH-685?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Chint New Energy Technology Co Ltd CHSM66N(DG)/F-BH-685.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 685.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 649.0 W (94.7% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 47.77 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 18.23 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 39.65 V / 17.28 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.269 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 22.03% (3.11 m2) | Array roof footprint density |
| Cell Count & Technology | 66 cells (Mono-c-Si) | Bifacial glass-glass |
How Many Chint New Energy Technology Co Ltd CHSM66N(DG)/F-BH-685 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Chint New Energy Technology Co Ltd CHSM66N(DG)/F-BH-685 (685.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 9 | 6.17 kW | 301 sq ft | $1,544 | $2,611 |
| 8 kW Class | 12 | 8.22 kW | 402 sq ft | $2,057 | $3,479 |
| 10 kW Class | 15 | 10.28 kW | 502 sq ft | $2,573 | $4,351 |
Which Sibling Wattage & Trim Variants Belong to This Chint New Energy Technology Co Ltd Series?
All closely matched Chint New Energy Technology Co Ltd wattages and cosmetic trims sharing the Chint New Energy Technology Co Ltd CHSM66N(DG)/F-BH-685 architecture.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Chint New Energy Technology Co Ltd CHSM66N(DG)/F-BH-675 | 675.0 W | 638.4 W | 47.37 V | 39.31 V | 21.7% |
| Chint New Energy Technology Co Ltd CHSM66N(DG)/F-BH-680 | 680.0 W | 643.2 W | 47.57 V | 39.48 V | 21.86% |
| Chint New Energy Technology Co Ltd CHSM66N(DG)/F-BH-685 | 685.0 W | 649.0 W | 47.77 V | 39.65 V | 22.03% |
| Chint New Energy Technology Co Ltd CHSM66N(DG)/F-BH-690 | 690.0 W | 653.9 W | 47.97 V | 39.82 V | 22.19% |
| Chint New Energy Technology Co Ltd CHSM66N(DG)/F-BH-695 | 695.0 W | 658.7 W | 48.17 V | 39.98 V | 22.35% |
How Many Chint New Energy Technology Co Ltd CHSM66N(DG)/F-BH-685 Modules Fit in a Cold-Weather String?
Maximum series module counts for Chint New Energy Technology Co Ltd CHSM66N(DG)/F-BH-685 from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 53.55 V | 11 panels | 589.0 V | 18 panels |
| -10 C (14 F) | 52.27 V | 11 panels | 575.0 V | 19 panels |
| 0 C (32 F) | 50.98 V | 11 panels | 560.8 V | 19 panels |
| 25 C (77 F STC) | 47.77 V | 12 panels | 573.2 V | 20 panels |
Which Cross-Brand Solar Modules Compare Closest to Chint New Energy Technology Co Ltd CHSM66N(DG)/F-BH-685?
Alternative CEC solar modules from competing brands near Chint New Energy Technology Co Ltd CHSM66N(DG)/F-BH-685 (685.0 W), including SUNPLUS OPTIMUM LIMITED SR5-66NHBD-685M.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| SUNPLUS OPTIMUM LIMITED SR5-66NHBD-685M SUNPLUS OPTIMUM LIMITED |
685.0 W | Tie (0 W) | 47.8 V | 22.03% | 94.6% |
| Trina Solar CoLtd TSM-685NEG21C20 Trina Solar CoLtd |
685.0 W | Tie (0 W) | 47.7 V | 22.24% | 94.6% |
| CSI Solar Co Ltd CS7N-685TB-AG CSI Solar Co Ltd |
685.0 W | Tie (0 W) | 47.3 V | 22.61% | 94.8% |
| WAAREE ENERGIES LIMITED BiN-03-690 WAAREE ENERGIES LIMITED |
690.0 W | +5.0 W | 47.8 V | 22.4% | 94.8% |
What Are the Design Limits and Best-Fit Uses for Chint New Energy Technology Co Ltd CHSM66N(DG)/F-BH-685?
Evaluate Chint New Energy Technology Co Ltd CHSM66N(DG)/F-BH-685 (685.0 W STC, 47.77 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Chint New Energy Technology Co Ltd CHSM66N(DG)/F-BH-685 reaches 53.55 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 12 panels for an 8 kW build require 402 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of Chint New Energy Technology Co Ltd CHSM66N(DG)/F-BH-685 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Chint New Energy Technology Co Ltd CHSM66N(DG)/F-BH-685 8 kW Residential Fit
Needs 12 modules (402 sq ft) with a 30 A string OCPD, offsetting ~$2,057/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare SUNPLUS OPTIMUM LIMITED SR5-66NHBD-685M.
Bifacial / High-Heat Roof Check
Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 649.0 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Chint New Energy Technology Co Ltd CHSM66N(DG)/F-BH-685 by Chint New Energy Technology Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Chint New Energy Technology Co Ltd CHSM66N(DG)/F-BH-685?
Multiplying Chint New Energy Technology Co Ltd CHSM66N(DG)/F-BH-685's 18.23 A short-circuit current by 1.56 equals 28.44 A minimum ampacity, requiring at least a 30 A overcurrent fuse or breaker.
Can Chint New Energy Technology Co Ltd CHSM66N(DG)/F-BH-685 pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 52.27 V cold Voc at 14 F and handles 18.23 A Isc; string inverters cap Chint New Energy Technology Co Ltd CHSM66N(DG)/F-BH-685 at 11 panels on 600 V.
Is Chint New Energy Technology Co Ltd CHSM66N(DG)/F-BH-685 eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Chint New Energy Technology Co Ltd CHSM66N(DG)/F-BH-685 rely on utility bill offset (~$2,057/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)