Topsun Co Ltd TOP CLASS 675CH12 is a 675.0 W STC (627.2 W PTC) Mono-c-Si solar module ranking #311 of 21,677 CEC listings (top 1.6%; higher than 98.4% of peers). It delivers 22.28% efficiency, 46.49 V Voc at 25 C, and 51.23 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 675.0 W
- PTC Wattage
- 627.2 W
- Voc @ 25C
- 46.49 V
- Efficiency
- 22.28%
How Does Topsun Co Ltd TOP CLASS 675CH12 Compare Against Peer CEC Listings?
How Topsun Co Ltd Topsun Co Ltd TOP CLASS 675CH12 handles rooftop heat (627.2 W PTC), 8 kW sizing, and cold winter string voltage.
Topsun Co Ltd builds the Topsun Co Ltd TOP CLASS 675CH12 (Mono-c-Si) as a large-format commercial and ground-mount module delivering 222.8 W/m2 (2.37 percentage points above 19.91% CEC median). Compared against Chint New Energy Technology Co Ltd CHSM66M(DG)/F-BH-675 (675.0 W), this model holds strong 92.9% PTC-to-STC heat retention (#10,348 of 21,677). Mid-range 46.49 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F, while NEC 690.8 sets a 28.97 A overcurrent floor served by a 30 A breaker.
Where Does Topsun Co Ltd TOP CLASS 675CH12 Fall Across Listed CEC Models?
Where Topsun Co Ltd TOP CLASS 675CH12 (675.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define Topsun Co Ltd TOP CLASS 675CH12?
Percentile placement of Topsun Co Ltd TOP CLASS 675CH12 across power density (222.8 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for Topsun Co Ltd TOP CLASS 675CH12?
Four critical engineering numbers homeowners and solar installers check first when reviewing Topsun Co Ltd TOP CLASS 675CH12 specifications.
Top 1.6% STC Output
675.0 W STC (+290.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
22.28% Aperture Efficiency
Power density 222.8 W/m2 (2.37 percentage points above 19.91% CEC median). PTC/STC ratio: 92.9% (rank #10,348).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 51.23 V at -10 C (563.5 V string) and 52.58 V at -20 C (11 max).
12 Panels = 8,100 W STC
Occupies 36.4 m2 (391 sq ft) producing 7,526 W PTC; NEC 690.8 OCPD floor is 28.97 A (30 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 46.49 * (1 + (-0.291/100) * (-10 - 25)) = 51.23 V | OCPD = 1.56 * 18.57 = 28.97 A
Inputs from CEC Modules.csv for Topsun Co Ltd TOP CLASS 675CH12: Voc=46.49 V, beta_Voc=-0.291%/C, Isc=18.57 A, STC=675.0 W, Area=3.03 m2.
Result: 11 panels max on 600 V (563.5 V); 12 panels for 8 kW (391 sq ft).
What Are the Published CEC Specifications for Topsun Co Ltd TOP CLASS 675CH12?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Topsun Co Ltd TOP CLASS 675CH12.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 675.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 627.2 W (92.9% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 46.49 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 18.57 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 38.68 V / 17.46 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.291 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 22.28% (3.03 m2) | Array roof footprint density |
| Cell Count & Technology | 66 cells (Mono-c-Si) | Bifacial glass-glass |
How Many Topsun Co Ltd TOP CLASS 675CH12 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Topsun Co Ltd TOP CLASS 675CH12 (675.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 9 | 6.08 kW | 294 sq ft | $1,522 | $2,573 |
| 8 kW Class | 12 | 8.1 kW | 391 sq ft | $2,027 | $3,428 |
| 10 kW Class | 15 | 10.12 kW | 489 sq ft | $2,533 | $4,283 |
How Many Topsun Co Ltd TOP CLASS 675CH12 Modules Fit in a Cold-Weather String?
Maximum series module counts for Topsun Co Ltd TOP CLASS 675CH12 from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 52.58 V | 11 panels | 578.4 V | 19 panels |
| -10 C (14 F) | 51.23 V | 11 panels | 563.5 V | 19 panels |
| 0 C (32 F) | 49.87 V | 12 panels | 598.4 V | 20 panels |
| 25 C (77 F STC) | 46.49 V | 12 panels | 557.9 V | 21 panels |
Which Cross-Brand Solar Modules Compare Closest to Topsun Co Ltd TOP CLASS 675CH12?
Alternative CEC solar modules from competing brands near Topsun Co Ltd TOP CLASS 675CH12 (675.0 W), including Chint New Energy Technology Co Ltd CHSM66M(DG)/F-BH-675.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Chint New Energy Technology Co Ltd CHSM66M(DG)/F-BH-675 Chint New Energy Technology Co Ltd |
675.0 W | Tie (0 W) | 46.49 V | 22.28% | 92.9% |
| SUNPLUS OPTIMUM LIMITED SR5-66HBD-675M SUNPLUS OPTIMUM LIMITED |
675.0 W | Tie (0 W) | 46.5 V | 22.28% | 92.9% |
| CW ENERJ M HEND SL K T CARET VE SANAY ANON M RKET CWT675-132PMB12 CW ENERJ M HEND SL K T CARET VE SANAY ANON M RKET |
675.0 W | Tie (0 W) | 46.2 V | 21.7% | 93.7% |
| Qcells North America QPEAK DUO ML-G12S3/BFG 675 Qcells North America |
675.0 W | Tie (0 W) | 45.74 V | 22.28% | 94.1% |
What Are the Design Limits and Best-Fit Uses for Topsun Co Ltd TOP CLASS 675CH12?
Evaluate Topsun Co Ltd TOP CLASS 675CH12 (675.0 W STC, 46.49 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Topsun Co Ltd TOP CLASS 675CH12 reaches 52.58 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 12 panels for an 8 kW build require 391 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of Topsun Co Ltd TOP CLASS 675CH12 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Topsun Co Ltd TOP CLASS 675CH12 8 kW Residential Fit
Needs 12 modules (391 sq ft) with a 30 A string OCPD, offsetting ~$2,027/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Chint New Energy Technology Co Ltd CHSM66M(DG)/F-BH-675.
Bifacial / High-Heat Roof Check
Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 627.2 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Topsun Co Ltd TOP CLASS 675CH12 by Topsun Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Topsun Co Ltd TOP CLASS 675CH12?
Multiplying Topsun Co Ltd TOP CLASS 675CH12's 18.57 A short-circuit current by 1.56 equals 28.97 A minimum ampacity, requiring at least a 30 A overcurrent fuse or breaker.
Can Topsun Co Ltd TOP CLASS 675CH12 pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 51.23 V cold Voc at 14 F and handles 18.57 A Isc; string inverters cap Topsun Co Ltd TOP CLASS 675CH12 at 11 panels on 600 V.
Is Topsun Co Ltd TOP CLASS 675CH12 eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Topsun Co Ltd TOP CLASS 675CH12 rely on utility bill offset (~$2,027/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)