Qcells North America QPEAK DUO ML-G12S3/BFG 675 — CEC Solar Module Specifications

Manufacturer: Qcells North America Registry: CEC Verified Engineering Specification

Qcells North America QPEAK DUO ML-G12S3/BFG 675 is a 675.0 W STC (635.2 W PTC) Mono-c-Si solar module ranking #311 of 21,677 CEC listings (top 1.6%; higher than 98.4% of peers). It delivers 22.28% efficiency, 45.74 V Voc at 25 C, and 49.95 V cold Voc at -10 C (12 panels max per 600 V string).

STC Wattage
675.0 W
PTC Wattage
635.2 W
Voc @ 25C
45.74 V
Efficiency
22.28%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Qcells North America QPEAK DUO ML-G12S3/BFG 675 Compare Against Peer CEC Listings?

How Qcells North America Qcells North America QPEAK DUO ML-G12S3/BFG 675 handles rooftop heat (635.2 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, Qcells North America QPEAK DUO ML-G12S3/BFG 675 exhibits 18.45 A short-circuit current, requiring a 28.78 A (156%) conductor rating and 30 A OCPD under NEC 690.8. Ranked #311 of 21,677 (265.0 W above the 410.0 W Mono-c-Si median), this large-format commercial and ground-mount module covers 36.4 m2 for an 8 kW system (15 panels for 10 kW). Mid-range 45.74 V open-circuit voltage allows up to 12 panels per 600 V string at 14 F.

Where Does Qcells North America QPEAK DUO ML-G12S3/BFG 675 Fall Across Listed CEC Models?

Where Qcells North America QPEAK DUO ML-G12S3/BFG 675 (675.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Qcells North America QPEAK DUO ML-G12S3/BFG 675 (675.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCQcells North Ameri: 675.0 W

What Dataset Percentiles Define Qcells North America QPEAK DUO ML-G12S3/BFG 675?

Percentile placement of Qcells North America QPEAK DUO ML-G12S3/BFG 675 across power density (222.8 W/m2), thermal retention, and nameplate STC wattage.

Qcells North America QPEAK DUO ML-G12S3/BFG 675 Engineering BenchmarksPercentile comparison of Qcells North America QPEAK DUO ML-G12S3/BFG 675 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage675.0 WPTC/STC Retention94.1%Module Efficiency22.28%

What Do the Dataset Ranks Show for Qcells North America QPEAK DUO ML-G12S3/BFG 675?

Four critical engineering numbers homeowners and solar installers check first when reviewing Qcells North America QPEAK DUO ML-G12S3/BFG 675 specifications.

Rank #311 / 21,677

Top 1.6% STC Output

675.0 W STC (+290.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #2,499

22.28% Aperture Efficiency

Power density 222.8 W/m2 (2.37 percentage points above 19.91% CEC median). PTC/STC ratio: 94.1% (rank #4,203).

NEC 690.7 Limit

12 Panels Max @ -10 C (600 V)

Cold Voc reaches 49.95 V at -10 C (599.4 V string) and 51.15 V at -20 C (11 max).

8 kW Reference Array

12 Panels = 8,100 W STC

Occupies 36.4 m2 (391 sq ft) producing 7,622 W PTC; NEC 690.8 OCPD floor is 28.78 A (30 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 45.74 * (1 + (-0.263/100) * (-10 - 25)) = 49.95 V | OCPD = 1.56 * 18.45 = 28.78 A

Inputs from CEC Modules.csv for Qcells North America QPEAK DUO ML-G12S3/BFG 675: Voc=45.74 V, beta_Voc=-0.263%/C, Isc=18.45 A, STC=675.0 W, Area=3.03 m2.

Result: 12 panels max on 600 V (599.4 V); 12 panels for 8 kW (391 sq ft).

What Are the Published CEC Specifications for Qcells North America QPEAK DUO ML-G12S3/BFG 675?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Qcells North America QPEAK DUO ML-G12S3/BFG 675.

Official California Energy Commission (NREL SAM) test parameters for Qcells North America QPEAK DUO ML-G12S3/BFG 675.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 675.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 635.2 W (94.1% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 45.74 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 18.45 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 38.43 V / 17.56 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.263 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 22.28% (3.03 m2) Array roof footprint density
Cell Count & Technology 66 cells (Mono-c-Si) Bifacial glass-glass

How Many Qcells North America QPEAK DUO ML-G12S3/BFG 675 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Qcells North America QPEAK DUO ML-G12S3/BFG 675 (675.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 9 6.08 kW 294 sq ft $1,522 $2,573
8 kW Class 12 8.1 kW 391 sq ft $2,027 $3,428
10 kW Class 15 10.12 kW 489 sq ft $2,533 $4,283

How Many Qcells North America QPEAK DUO ML-G12S3/BFG 675 Modules Fit in a Cold-Weather String?

Maximum series module counts for Qcells North America QPEAK DUO ML-G12S3/BFG 675 from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=45.74V and beta_Voc=-0.263%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 51.15 V 11 panels 562.6 V 19 panels
-10 C (14 F) 49.95 V 12 panels 599.4 V 20 panels
0 C (32 F) 48.75 V 12 panels 585.0 V 20 panels
25 C (77 F STC) 45.74 V 13 panels 594.6 V 21 panels

Which Cross-Brand Solar Modules Compare Closest to Qcells North America QPEAK DUO ML-G12S3/BFG 675?

Alternative CEC solar modules from competing brands near Qcells North America QPEAK DUO ML-G12S3/BFG 675 (675.0 W), including CW ENERJ M HEND SL K T CARET VE SANAY ANON M RKET CWT675-132PMB12.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
CW ENERJ M HEND SL K T CARET VE SANAY ANON M RKET CWT675-132PMB12
CW ENERJ M HEND SL K T CARET VE SANAY ANON M RKET
675.0 W Tie (0 W) 46.2 V 21.7% 93.7%
Chint New Energy Technology Co Ltd CHSM66M(DG)/F-BH-675
Chint New Energy Technology Co Ltd
675.0 W Tie (0 W) 46.49 V 22.28% 92.9%
Topsun Co Ltd TOP CLASS 675CH12
Topsun Co Ltd
675.0 W Tie (0 W) 46.49 V 22.28% 92.9%
SUNPLUS OPTIMUM LIMITED SR5-66HBD-675M
SUNPLUS OPTIMUM LIMITED
675.0 W Tie (0 W) 46.5 V 22.28% 92.9%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Qcells North America QPEAK DUO ML-G12S3/BFG 675?

Evaluate Qcells North America QPEAK DUO ML-G12S3/BFG 675 (675.0 W STC, 45.74 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Qcells North America QPEAK DUO ML-G12S3/BFG 675 reaches 51.15 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 12 panels for an 8 kW build require 391 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
  • 2026 tax credit baseline: cash residential installs of Qcells North America QPEAK DUO ML-G12S3/BFG 675 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Qcells North America QPEAK DUO ML-G12S3/BFG 675 8 kW Residential Fit

Needs 12 modules (391 sq ft) with a 30 A string OCPD, offsetting ~$2,027/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 12 panels (-10 C) or 11 panels (-20 C), or compare CW ENERJ M HEND SL K T CARET VE SANAY ANON M RKET CWT675-132PMB12.

Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 635.2 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Qcells North America QPEAK DUO ML-G12S3/BFG 675 by Qcells North America grounded in CEC test data and NEC 690.7/690.8 limits.

Why is Qcells North America QPEAK DUO ML-G12S3/BFG 675 PTC wattage (635.2 W) lower than STC (675.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 635.2 W PTC (94.1% retention) across Qcells North America QPEAK DUO ML-G12S3/BFG 675's 3.03 m2 aperture.

Who should skip Qcells North America QPEAK DUO ML-G12S3/BFG 675 on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 12 Qcells North America QPEAK DUO ML-G12S3/BFG 675 panels (391 sq ft) leave unusable roof gaps vs. CW ENERJ M HEND SL K T CARET VE SANAY ANON M RKET CWT675-132PMB12.

What is the 1,000 V commercial string limit for Qcells North America QPEAK DUO ML-G12S3/BFG 675?

On 1,000 V commercial inverters at -10 C (49.95 V cold Voc), Qcells North America QPEAK DUO ML-G12S3/BFG 675 fits up to 20 panels per series string.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.