Trystar LLC: OZPCS-RS35-FB0 {240V} — CEC Inverter Specifications

Manufacturer: Trystar LLC Registry: CEC Verified Engineering Specification

Trystar LLC: OZPCS-RS35-FB0 {240V} outputs 23,446 W AC at 240 V (97.7 A continuous, 125 A OCPD), ranking #2,238 of 2,343 CEC inverters at 95.16% efficiency with a 400-800 V MPPT window and 800 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
23,446 W
AC Voltage
240 V
Min PV Breaker
125 A (1 AWG Cu)
CEC Efficiency
95.16%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Trystar LLC: OZPCS-RS35-FB0 {240V} Compare Against Peer CEC Listings?

How Trystar LLC Trystar LLC: OZPCS-RS35-FB0 {240V} compares on 95.16% efficiency, MPPT span, and 120% busbar interconnection. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

With a 400-800 V MPPT tracking band and 800 V DC ceiling, Trystar LLC: OZPCS-RS35-FB0 {240V} handles 23,446 W continuous AC (17,670 W above the 5,776 W 240 V median). Its 125 A backfeed breaker exceeds a 200A/200A panel's 40 A ceiling, requiring a 175 A main derate, 225 A busbar, or NEC 705.11 tap. Installers comparing Trystar LLC against Amensolar Ess Co Ltd: N3H-X16US {240V} (16,199 W) should verify whether active in CEC directory grid-support firmware meets local IEEE 1547 utility rules.

Where Does Trystar LLC: OZPCS-RS35-FB0 {240V} Fall Across Listed CEC Models?

Position of Trystar LLC: OZPCS-RS35-FB0 {240V} (23,446 W AC) relative to the 7,680 W CEC median inverter. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where Trystar LLC: OZPCS-RS35-FB0 {240V} (23,446 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACTrystar LLC: OZPCS: 23,446 W

What Dataset Percentiles Define Trystar LLC: OZPCS-RS35-FB0 {240V}?

Percentile placement of Trystar LLC: OZPCS-RS35-FB0 {240V} across AC power class, conversion efficiency, and backfeed breaker size. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Trystar LLC: OZPCS-RS35-FB0 {240V} Technical ThresholdsPercentile comparison for Trystar LLC: OZPCS-RS35-FB0 {240V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output23,446 WCEC Efficiency95.16%Backfeed Breaker125 A

What Do the Dataset Ranks Show for Trystar LLC: OZPCS-RS35-FB0 {240V}?

Primary electrical sizing limits, efficiency ranks, and NEC 705.12 / 690.7 thresholds for Trystar LLC: OZPCS-RS35-FB0 {240V}. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Eff #2,238 / 2,343

95.16% CEC Weighted Efficiency

-1.52 pts vs the 96.68% 240 V median; overall power rank #620 (23,446 W, top 26.5%; higher than 73.5% of peers).

NEC 705.12 Check

125 A Required Backfeed OCPD

125% x 97.7 A = 122.1 A -> 125 A standard OCPD using 1 AWG Cu (75 C).

MPPT Window

400 V - 800 V (Max 800 V DC)

Tracking span of 400.0 V; active in CEC directory (grid-tied PV inverter).

Panel Fit (240V)

Needs Derate / Tap 705.11

200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 23446.3W / 240 V -> 97.7 A | Breaker >= 1.25 * 97.7 = 122.1 A -> 125 A

CEC Inverters.csv for Trystar LLC: OZPCS-RS35-FB0 {240V}: Paco=23446.3 W, Vac=240 V, Vdcmax=800.0 V, Eff=95.16%.

Result: Min 125 A breaker & 1 AWG Cu (75 C); 200A Bus / 200A Main: Needs Derate / Tap 705.11.

What Are the Published CEC Specifications for Trystar LLC: OZPCS-RS35-FB0 {240V}?

Official California Energy Commission electrical test parameters, AC voltage, and DC limits for Trystar LLC: OZPCS-RS35-FB0 {240V}. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Official California Energy Commission (NREL SAM) test parameters for Trystar LLC: OZPCS-RS35-FB0 {240V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 23,446 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 240 V 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 800 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 400 V - 800 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 41.0658 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 95.16% Calculated AC/DC conversion ratio from CEC test protocol
Inverter Topology Hybrid: No (Grid-Tied PV) CEC Solar Equipment List grid-support certification

Can a Residential Panel Meet 120% Busbar Limits for Trystar LLC: OZPCS-RS35-FB0 {240V}?

Check whether Trystar LLC: OZPCS-RS35-FB0 {240V} (125 A breaker) fits without main breaker derate or supply-side taps. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Evaluates Trystar LLC: OZPCS-RS35-FB0 {240V} (125 A required OCPD at 240 V) across standard distribution busbars.
Panel Configuration120% Max BackfeedRequired PV OCPDCompliance Verdict
100A Bus / 100A Main 20 A 125 A Needs Derate / Tap 705.11
150A Bus / 150A Main 30 A 125 A Needs Derate / Tap 705.11
200A Bus / 200A Main 40 A 125 A Needs Derate / Tap 705.11
200A Bus / 175A Main 65 A 125 A Needs Derate / Tap 705.11
225A Bus / 200A Main 70 A 125 A Needs Derate / Tap 705.11

Which CEC PV Module Strings Pair With Trystar LLC: OZPCS-RS35-FB0 {240V}?

Verified cold-weather (-10 C) series module counts matched to Trystar LLC: OZPCS-RS35-FB0 {240V}'s 800 V DC ceiling.

Sampled CEC PV modules aligned within 400.0-800.0 V MPPT and 800.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
AXITEC AC-590TGB/144TS 590.0 W 56.24 V 10 to 14 panels 8.26 kW
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 12 to 18 panels 7.92 kW
Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF 425.0 W 44.75 V 12 to 17 panels 7.22 kW
CSI Solar Co Ltd CS6P-200P 200.0 W 40.6 V 14 to 19 panels 3.8 kW

Which Competing Grid-Support Inverters Compare to Trystar LLC: OZPCS-RS35-FB0 {240V}?

Alternative CEC inverters comparable to Trystar LLC: OZPCS-RS35-FB0 {240V}, including Amensolar Ess Co Ltd: N3H-X16US {240V} (16,199 W) at 240 V.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
Amensolar Ess Co Ltd: N3H-X16US {240V}
Amensolar Ess Co Ltd
16,199 W -7247 W 240.0 V 430.0 V 96.25%
Amensolar Ess Co Ltd: N3H-X12US {240V}
Amensolar Ess Co Ltd
12,214 W -11232 W 240.0 V 430.0 V 96.17%
Chint Power Systems America: CPS ECH12KTL/US {240V}
Chint Power Systems America
11,990 W -11456 W 240.0 V 480.0 V 96.59%
Delta Electronics: S12_BDI {240V}
Delta Electronics
11,589 W -11858 W 240.0 V 480.0 V 96.99%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for Trystar LLC: OZPCS-RS35-FB0 {240V}?

Check Trystar LLC: OZPCS-RS35-FB0 {240V} (23,446 W AC, 125 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Its 125 A backfeed breaker exceeds a 200A/200A panel's 40 A ceiling, requiring a 175 A main derate, 225 A busbar, or NEC 705.11 tap.
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 800 V DC on Trystar LLC: OZPCS-RS35-FB0 {240V}.

Trystar LLC: OZPCS-RS35-FB0 {240V} Panel & Wire Spec

Size 75 C copper conductors at 1 AWG Cu on a 125 A OCPD breaker (97.7 A continuous).

Alternative Inverter Comparison

Compare efficiency (95.16%) and MPPT window (400-800 V) directly against Amensolar Ess Co Ltd: N3H-X16US {240V} (16,199 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Trystar LLC: OZPCS-RS35-FB0 {240V} by Trystar LLC covering breaker sizing, MPPT limits, and 240 V interconnection.

What breaker and wire size does Trystar LLC: OZPCS-RS35-FB0 {240V} require?

At 23,446 W continuous AC (240 V), continuous current is 97.7 A; 125% NEC 690.8/705.12 sizing requires a 125 A breaker and 1 AWG Cu (75 C) wire.

Does Trystar LLC: OZPCS-RS35-FB0 {240V} fit a 200 A main panel under the 120% busbar rule?

A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 125 A at 240 V means Needs Derate / Tap 705.11.

How does Trystar LLC: OZPCS-RS35-FB0 {240V} compare to Amensolar Ess Co Ltd: N3H-X16US {240V}?

Trystar LLC: OZPCS-RS35-FB0 {240V} delivers 23,446 W AC at 95.16% CEC efficiency with a 800 V DC ceiling, while Amensolar Ess Co Ltd: N3H-X16US {240V} outputs 16,199 W at 240 V.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.