SolarEdge Technologies Ltd: SE7600H-US {208V} outputs 6,592 W AC at 208 V, commercial single-phase (31.7 A continuous, 40 A OCPD), ranking #97 of 2,343 CEC inverters at 98.46% efficiency with a 360-460 V MPPT window and 460 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.
- AC Output (Paco)
- 6,592 W
- AC Voltage
- 208 V, commercial single-phase
- Min PV Breaker
- 40 A (8 AWG Cu)
- CEC Efficiency
- 98.46%
How Does SolarEdge Technologies Ltd: SE7600H-US {208V} Compare Against Peer CEC Listings?
NEC 705.12 breaker requirements, efficiency placement, and 208 V, commercial single-phase grid-support overview for SolarEdge Technologies Ltd: SE7600H-US {208V}.
Rated at 6,592 W AC (31.7 A continuous), SolarEdge Technologies Ltd: SE7600H-US {208V} ranks #97 of 2,343 CEC units at 98.46% efficiency (+2.05 pts vs the 96.41% 208 V median). Minimum 75 C copper conductor sizing for its 40 A circuit is 8 AWG Cu per NEC Table 310.16. Cold-weather string Voc must remain under 460 V DC at record local winter lows.
Where Does SolarEdge Technologies Ltd: SE7600H-US {208V} Fall Across Listed CEC Models?
Marks SolarEdge Technologies Ltd: SE7600H-US {208V} (6,592 W AC) across the California Energy Commission inverter AC capacity distribution.
What Dataset Percentiles Define SolarEdge Technologies Ltd: SE7600H-US {208V}?
Benchmarks SolarEdge Technologies Ltd: SE7600H-US {208V} continuous AC output, 98.46% CEC weighted efficiency, and 40 A OCPD breaker demand.
What Do the Dataset Ranks Show for SolarEdge Technologies Ltd: SE7600H-US {208V}?
Four key NEC 705.12 and California Energy Commission metrics defining SolarEdge Technologies Ltd: SE7600H-US {208V} by SolarEdge Technologies Ltd.
98.46% CEC Weighted Efficiency
+2.05 pts vs the 96.41% 208 V median; overall power rank #1,335 (6,592 W, below CEC median; higher than 43.0% of peers).
40 A Required Backfeed OCPD
125% x 31.7 A = 39.6 A -> 40 A standard OCPD using 8 AWG Cu (75 C).
360 V - 460 V (Max 460 V DC)
Tracking span of 100.0 V; active in CEC directory (hybrid battery-capable inverter).
PASS (120% Commercial Busbar)
Evaluated for 208 V, commercial single-phase switchgear (200A Bus / 200A Main (208V) to 1,200A Bus / 1,200A Main (208V)) under NEC 705.12 / 705.11.
NEC 705.12 Backfeed OCPD & 120% Busbar Formula
I_cont = 6591.8W / 208 V -> 31.7 A | Breaker >= 1.25 * 31.7 = 39.6 A -> 40 A
CEC Inverters.csv for SolarEdge Technologies Ltd: SE7600H-US {208V}: Paco=6591.8 W, Vac=208 V, Vdcmax=460.0 V, Eff=98.46%.
Result: Min 40 A breaker & 8 AWG Cu (75 C); 1,200A Bus / 1,200A Main (208V): PASS (120% Commercial Busbar).
What Are the Published CEC Specifications for SolarEdge Technologies Ltd: SE7600H-US {208V}?
Official laboratory CEC ratings, MPPT operating window, and DC voltage bounds recorded for SolarEdge Technologies Ltd: SE7600H-US {208V}.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Max Continuous AC Power (Paco) | 6,592 W | Determines required backfeed OCPD size via 125% continuous rule |
| Nominal AC Voltage (Vac) | 208 V, commercial single-phase | 240V split-phase residential vs. 208V/480V/MV commercial |
| Max DC Input Voltage (Vdcmax) | 460 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| MPPT Operating Range | 360 V - 460 V | Optimal DC string Vmp window for full power harvest |
| Max Input DC Current (Idcmax) | 16.9487 A | Used to verify parallel string combiner limits |
| CEC Weighted Efficiency | 98.46% | Calculated AC/DC conversion ratio from CEC test protocol |
| Inverter Topology | Hybrid: Yes (Battery Capable) | CEC Solar Equipment List grid-support certification |
What Switchgear Limits Apply to SolarEdge Technologies Ltd: SE7600H-US {208V} (208 V, commercial single-phase)?
Evaluates SolarEdge Technologies Ltd: SE7600H-US {208V} (40 A OCPD) across standard 100 A to 225 A busbars or commercial switchboards.
| Switchboard / Interconnect | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| 200A Bus / 200A Main (208V) | 40 A | 40 A | PASS (120% Commercial Busbar) |
| 400A Bus / 400A Main (208V) | 80 A | 40 A | PASS (120% Commercial Busbar) |
| 600A Bus / 600A Main (208V) | 120 A | 40 A | PASS (120% Commercial Busbar) |
| 800A Bus / 800A Main (208V) | 160 A | 40 A | PASS (120% Commercial Busbar) |
| 1,200A Bus / 1,200A Main (208V) | 240 A | 40 A | PASS (120% Commercial Busbar) |
Which Competing Grid-Support Inverters Compare to SolarEdge Technologies Ltd: SE7600H-US {208V}?
Competing CEC grid-support inverters near 6,592 W AC and 208 V, commercial single-phase, led by Delta Electronics: SOLIVIA 66 NA G4 TL {208V}.
| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| Delta Electronics: SOLIVIA 66 NA G4 TL {208V} Delta Electronics |
6,600 W | +8 W | 208.0 V | 500.0 V | 97.02% |
| Delta Electronics: SOLIVIA 76 NA G4 TL {208V} Delta Electronics |
6,600 W | +8 W | 208.0 V | 500.0 V | 97.02% |
| Altenergy Power System Inc: ELS-76 {208V} Altenergy Power System Inc |
6,606 W | +14 W | 208.0 V | 60.0 V | 93.96% |
| Delta Electronics: E8-TL-US {208V} Delta Electronics |
6,656 W | +64 W | 208.0 V | 480.0 V | 97.21% |
What Are the Interconnection Limits and Best-Fit Uses for SolarEdge Technologies Ltd: SE7600H-US {208V}?
Check SolarEdge Technologies Ltd: SE7600H-US {208V} (6,592 W AC, 40 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.
- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Commercial 208 V, commercial single-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (208V) or NEC 705.11 supply-side tap.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 460 V DC on SolarEdge Technologies Ltd: SE7600H-US {208V}.
SolarEdge Technologies Ltd: SE7600H-US {208V} Panel & Wire Spec
Size 75 C copper conductors at 8 AWG Cu on a 40 A OCPD breaker (31.7 A continuous).
Alternative Inverter Comparison
Compare efficiency (98.46%) and MPPT window (360-460 V) directly against Delta Electronics: SOLIVIA 66 NA G4 TL {208V} (6,600 W).
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Answers for SolarEdge Technologies Ltd: SE7600H-US {208V} by SolarEdge Technologies Ltd covering breaker sizing, MPPT limits, and 208 V, commercial single-phase interconnection.
What breaker and wire size does SolarEdge Technologies Ltd: SE7600H-US {208V} require?
At 6,592 W continuous AC (208 V, commercial single-phase), continuous current is 31.7 A; 125% NEC 690.8/705.12 sizing requires a 40 A breaker and 8 AWG Cu (75 C) wire.
What commercial switchgear or feeder sizing does SolarEdge Technologies Ltd: SE7600H-US {208V} require?
At 6,592 W AC and 208 V, commercial single-phase, continuous line current is 31.7 A, requiring a 40 A OCPD and 1,200A Bus / 1,200A Main (208V) or NEC 705.11 interconnection.
How does SolarEdge Technologies Ltd: SE7600H-US {208V} compare to Delta Electronics: SOLIVIA 66 NA G4 TL {208V}?
SolarEdge Technologies Ltd: SE7600H-US {208V} delivers 6,592 W AC at 98.46% CEC efficiency with a 460 V DC ceiling, while Delta Electronics: SOLIVIA 66 NA G4 TL {208V} outputs 6,600 W at 208 V, commercial single-phase.
Sources
- CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)