Skip to main content
WireAndSun
Calculators
CEC Grid-Support Inverter

SolarEdge Technologies Ltd: SE5000x {240V} — CEC Inverter Specifications

Manufacturer: SolarEdge Technologies Ltd Registry: CEC Verified Engineering Specification

SolarEdge Technologies Ltd: SE5000x {240V} outputs 4,990 W AC at 240 V (20.8 A continuous, 30 A OCPD), ranking #331 of 2,343 CEC inverters at 98.04% efficiency with a 370-480 V MPPT window and 480 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
4,990 W
AC Voltage
240 V
Min PV Breaker
30 A (10 AWG Cu)
CEC Efficiency
98.04%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does SolarEdge Technologies Ltd: SE5000x {240V} Compare Against Peer CEC Listings?

CEC efficiency rank (#331), 370-480 V MPPT tracking, and panel fit for SolarEdge Technologies Ltd: SE5000x {240V}. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Operating at 240 V, SolarEdge Technologies Ltd: SE5000x {240V} converts DC array energy at 98.04% CEC weighted efficiency (top 14.3%; higher than 85.7% of peers) with a 480 V max DC input and 12.7243 A max input current for NEC 690.7 string safety. Compare this 4,990 W grid-tied PV inverter directly with Afore New Energy Technology (Shanghai) Co Ltd: AF5K-DH {240V} (4,998 W). Requires a 30 A breaker, passing directly inside a standard 200 A main / 200 A busbar panel (40 A limit).

Where Does SolarEdge Technologies Ltd: SE5000x {240V} Fall Across Listed CEC Models?

CEC inverter wattage histogram highlighting SolarEdge Technologies Ltd: SE5000x {240V} at 4,990 W continuous AC output. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where SolarEdge Technologies Ltd: SE5000x {240V} (4,990 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACSolarEdge Technolo: 4,990 W

What Dataset Percentiles Define SolarEdge Technologies Ltd: SE5000x {240V}?

Dataset percentiles comparing SolarEdge Technologies Ltd: SE5000x {240V} against 2,343 certified grid-support inverters nationwide. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

SolarEdge Technologies Ltd: SE5000x {240V} Technical ThresholdsPercentile comparison for SolarEdge Technologies Ltd: SE5000x {240V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output4,990 WCEC Efficiency98.04%Backfeed Breaker30 A

What Do the Dataset Ranks Show for SolarEdge Technologies Ltd: SE5000x {240V}?

Engineering highlights for SolarEdge Technologies Ltd: SE5000x {240V} covering efficiency, 10 AWG Cu feeder, and panel compatibility. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Eff #331 / 2,343

98.04% CEC Weighted Efficiency

+1.36 pts vs the 96.68% 240 V median; overall power rank #1,553 (4,990 W, below CEC median; higher than 33.6% of peers).

NEC 705.12 Check

30 A Required Backfeed OCPD

125% x 20.8 A = 26.0 A -> 30 A standard OCPD using 10 AWG Cu (75 C).

MPPT Window

370 V - 480 V (Max 480 V DC)

Tracking span of 110.0 V; listed since 2018-10-15 (grid-tied PV inverter).

Panel Fit (240V)

PASS (120% Rule)

200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 4990.0W / 240 V -> 20.8 A | Breaker >= 1.25 * 20.8 = 26.0 A -> 30 A

CEC Inverters.csv for SolarEdge Technologies Ltd: SE5000x {240V}: Paco=4990.0 W, Vac=240 V, Vdcmax=480.0 V, Eff=98.04%.

Result: Min 30 A breaker & 10 AWG Cu (75 C); 200A Bus / 200A Main: PASS (120% Rule).

What Are the Published CEC Specifications for SolarEdge Technologies Ltd: SE5000x {240V}?

California Energy Commission Solar Equipment List parameters for SolarEdge Technologies Ltd: SE5000x {240V} (grid-tied PV inverter) interconnection. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Official California Energy Commission (NREL SAM) test parameters for SolarEdge Technologies Ltd: SE5000x {240V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 4,990 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 240 V 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 480 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 370 V - 480 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 12.7243 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 98.04% Calculated AC/DC conversion ratio from CEC test protocol
CEC Listing Date & Hybrid 2018-10-15 / Hybrid: No (Grid-Tied PV) Utility interconnection approval metadata

Can a Residential Panel Meet 120% Busbar Limits for SolarEdge Technologies Ltd: SE5000x {240V}?

Panelboard and switchgear backfeed allowances for SolarEdge Technologies Ltd: SE5000x {240V} (30 A OCPD). Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Evaluates SolarEdge Technologies Ltd: SE5000x {240V} (30 A required OCPD at 240 V) across standard distribution busbars.
Panel Configuration120% Max BackfeedRequired PV OCPDCompliance Verdict
100A Bus / 100A Main 20 A 30 A Needs Derate / Tap 705.11
150A Bus / 150A Main 30 A 30 A PASS (120% Rule)
200A Bus / 200A Main 40 A 30 A PASS (120% Rule)
200A Bus / 175A Main 65 A 30 A PASS (120% Rule)
225A Bus / 200A Main 70 A 30 A PASS (120% Rule)

Which Competing Grid-Support Inverters Compare to SolarEdge Technologies Ltd: SE5000x {240V}?

Four alternative CEC inverters matched to SolarEdge Technologies Ltd: SE5000x {240V} (4,990 W AC), led by Afore New Energy Technology (Shanghai) Co Ltd: AF5K-DH {240V}.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
Afore New Energy Technology (Shanghai) Co Ltd: AF5K-DH {240V}
Afore New Energy Technology (Shanghai) Co Ltd
4,998 W +8 W 240.0 V 480.0 V 97.76%
ABB: PVI-5000-OUTD-US-A {240V}
ABB
5,000 W +10 W 240.0 V 480.0 V 96.33%
ABB: PVI-5000-OUTD-US-Z-A {240V}
ABB
5,000 W +10 W 240.0 V 480.0 V 96.33%
ABB: PVI-5000-OUTD-US-Z-M-A {240V}
ABB
5,000 W +10 W 240.0 V 480.0 V 96.33%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for SolarEdge Technologies Ltd: SE5000x {240V}?

Check SolarEdge Technologies Ltd: SE5000x {240V} (4,990 W AC, 30 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Requires a 30 A breaker, passing directly inside a standard 200 A main / 200 A busbar panel (40 A limit).
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 480 V DC on SolarEdge Technologies Ltd: SE5000x {240V}.

SolarEdge Technologies Ltd: SE5000x {240V} Panel & Wire Spec

Size 75 C copper conductors at 10 AWG Cu on a 30 A OCPD breaker (20.8 A continuous).

Alternative Inverter Comparison

Compare efficiency (98.04%) and MPPT window (370-480 V) directly against Afore New Energy Technology (Shanghai) Co Ltd: AF5K-DH {240V} (4,998 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for SolarEdge Technologies Ltd: SE5000x {240V} by SolarEdge Technologies Ltd covering breaker sizing, MPPT limits, and 240 V interconnection.

What breaker and wire size does SolarEdge Technologies Ltd: SE5000x {240V} require?

At 4,990 W continuous AC (240 V), continuous current is 20.8 A; 125% NEC 690.8/705.12 sizing requires a 30 A breaker and 10 AWG Cu (75 C) wire.

Does SolarEdge Technologies Ltd: SE5000x {240V} fit a 200 A main panel under the 120% busbar rule?

A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 30 A at 240 V means PASS (120% Rule).

How does SolarEdge Technologies Ltd: SE5000x {240V} compare to Afore New Energy Technology (Shanghai) Co Ltd: AF5K-DH {240V}?

SolarEdge Technologies Ltd: SE5000x {240V} delivers 4,990 W AC at 98.04% CEC efficiency with a 480 V DC ceiling, while Afore New Energy Technology (Shanghai) Co Ltd: AF5K-DH {240V} outputs 4,998 W at 240 V.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.