Skip to main content
WireAndSun
Calculators
CEC Grid-Support Inverter

DYNAPOWER COMPANY LLC: MPS-100 {480V} — CEC Inverter Specifications

Manufacturer: DYNAPOWER COMPANY LLC Registry: CEC Verified Engineering Specification

DYNAPOWER COMPANY LLC: MPS-100 {480V} outputs 98,861 W AC at 480 V, 3-phase (118.9 A continuous, 150 A OCPD), ranking #2,177 of 2,343 CEC inverters at 95.47% efficiency with a 350-600 V MPPT window and 600 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
98,861 W
AC Voltage
480 V, 3-phase
Min PV Breaker
150 A (1/0 AWG Cu)
CEC Efficiency
95.47%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does DYNAPOWER COMPANY LLC: MPS-100 {480V} Compare Against Peer CEC Listings?

CEC efficiency rank (#2,177), 350-600 V MPPT tracking, and panel fit for DYNAPOWER COMPANY LLC: MPS-100 {480V}. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

DYNAPOWER COMPANY LLC: MPS-100 {480V} from DYNAPOWER COMPANY LLC outputs 118.9 A continuous AC at 480 V, 3-phase (98,861 W AC, rank #351). Paired with 1/0 AWG Cu conductors and a 150 A OCPD, its 95.47% CEC efficiency compares closely with CSI Solar Co Ltd: CSI-100K-T480GL03-U {480V} (99,368 W). Keep NEC 690.7 winter string Voc below 600 V DC.

Where Does DYNAPOWER COMPANY LLC: MPS-100 {480V} Fall Across Listed CEC Models?

CEC inverter wattage histogram highlighting DYNAPOWER COMPANY LLC: MPS-100 {480V} at 98,861 W continuous AC output. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where DYNAPOWER COMPANY LLC: MPS-100 {480V} (98,861 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACDYNAPOWER COMPANY : 98,861 W

What Dataset Percentiles Define DYNAPOWER COMPANY LLC: MPS-100 {480V}?

Dataset percentiles comparing DYNAPOWER COMPANY LLC: MPS-100 {480V} against 2,343 certified grid-support inverters nationwide. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

DYNAPOWER COMPANY LLC: MPS-100 {480V} Technical ThresholdsPercentile comparison for DYNAPOWER COMPANY LLC: MPS-100 {480V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output98,861 WCEC Efficiency95.47%Backfeed Breaker150 A

What Do the Dataset Ranks Show for DYNAPOWER COMPANY LLC: MPS-100 {480V}?

Engineering highlights for DYNAPOWER COMPANY LLC: MPS-100 {480V} covering efficiency, 1/0 AWG Cu feeder, and panel compatibility.

Eff #2,177 / 2,343

95.47% CEC Weighted Efficiency

-2.55 pts vs the 98.02% 480 V median; overall power rank #351 (98,861 W, top 15.0%; higher than 85.0% of peers).

NEC 705.12 Check

150 A Required Backfeed OCPD

125% x 118.9 A = 148.6 A -> 150 A standard OCPD using 1/0 AWG Cu (75 C).

MPPT Window

350 V - 600 V (Max 600 V DC)

Tracking span of 250.0 V; active in CEC directory (grid-tied PV inverter).

Commercial / 3-Phase Fit

Supply-Side Tap (705.11) / Dedicated Switchboard

Evaluated for 480 V, 3-phase switchgear (200A Bus / 200A Main (480V) to 1,200A Bus / 1,200A Main (480V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 98861.0W / 480 V 3-phase -> 118.9 A | Breaker >= 1.25 * 118.9 = 148.6 A -> 150 A

CEC Inverters.csv for DYNAPOWER COMPANY LLC: MPS-100 {480V}: Paco=98861.0 W, Vac=480 V, Vdcmax=600.0 V, Eff=95.47%.

Result: Min 150 A breaker & 1/0 AWG Cu (75 C); 1,200A Bus / 1,200A Main (480V): PASS (120% Commercial Busbar).

What Are the Published CEC Specifications for DYNAPOWER COMPANY LLC: MPS-100 {480V}?

California Energy Commission Solar Equipment List parameters for DYNAPOWER COMPANY LLC: MPS-100 {480V} (grid-tied PV inverter) interconnection. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Official California Energy Commission (NREL SAM) test parameters for DYNAPOWER COMPANY LLC: MPS-100 {480V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 98,861 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 480 V, 3-phase 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 600 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 350 V - 600 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 218.01 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 95.47% Calculated AC/DC conversion ratio from CEC test protocol
Inverter Topology Hybrid: No (Grid-Tied PV) CEC Solar Equipment List grid-support certification

What Switchgear Limits Apply to DYNAPOWER COMPANY LLC: MPS-100 {480V} (480 V, 3-phase)?

Panelboard and switchgear backfeed allowances for DYNAPOWER COMPANY LLC: MPS-100 {480V} (150 A OCPD). Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Evaluates DYNAPOWER COMPANY LLC: MPS-100 {480V} (150 A required OCPD at 480 V, 3-phase) across standard distribution busbars.
Switchboard / Interconnect120% Max BackfeedRequired PV OCPDCompliance Verdict
200A Bus / 200A Main (480V) 40 A 150 A Supply-Side Tap (705.11) / Dedicated Switchboard
400A Bus / 400A Main (480V) 80 A 150 A Supply-Side Tap (705.11) / Dedicated Switchboard
600A Bus / 600A Main (480V) 120 A 150 A Supply-Side Tap (705.11) / Dedicated Switchboard
800A Bus / 800A Main (480V) 160 A 150 A PASS (120% Commercial Busbar)
1,200A Bus / 1,200A Main (480V) 240 A 150 A PASS (120% Commercial Busbar)

Which CEC PV Module Strings Pair With DYNAPOWER COMPANY LLC: MPS-100 {480V}?

Representative PV panel pairings verified under NEC 690.7 cold Voc for DYNAPOWER COMPANY LLC: MPS-100 {480V}. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Sampled CEC PV modules aligned within 350.0-600.0 V MPPT and 600.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
AXITEC AC-590TGB/144TS 590.0 W 56.24 V 9 to 10 panels 5.9 kW
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 11 to 14 panels 6.16 kW
Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF 425.0 W 44.75 V 11 to 13 panels 5.53 kW
CSI Solar Co Ltd CS6P-200P 200.0 W 40.6 V 13 to 14 panels 2.8 kW

Which Competing Grid-Support Inverters Compare to DYNAPOWER COMPANY LLC: MPS-100 {480V}?

Four alternative CEC inverters matched to DYNAPOWER COMPANY LLC: MPS-100 {480V} (98,861 W AC), led by CSI Solar Co Ltd: CSI-100K-T480GL03-U {480V}.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
CSI Solar Co Ltd: CSI-100K-T480GL03-U {480V}
CSI Solar Co Ltd
99,368 W +507 W 480.0 V 850.0 V 97.92%
Ginlong Technologies Co Ltd: S5-GC100K-US {480V}
Ginlong Technologies Co Ltd
99,368 W +507 W 480.0 V 850.0 V 97.92%
Delta Electronics: M100U_280 {480V}
Delta Electronics
99,975 W +1114 W 480.0 V 840.0 V 97.95%
Chint Power Systems America: CPS SCH100KTL-DO/US-480 {480V}
Chint Power Systems America
100,000 W +1139 W 480.0 V 1300.0 V 97.79%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for DYNAPOWER COMPANY LLC: MPS-100 {480V}?

Check DYNAPOWER COMPANY LLC: MPS-100 {480V} (98,861 W AC, 150 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Commercial 480 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (480V) or NEC 705.11 supply-side tap.
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 600 V DC on DYNAPOWER COMPANY LLC: MPS-100 {480V}.

DYNAPOWER COMPANY LLC: MPS-100 {480V} Panel & Wire Spec

Size 75 C copper conductors at 1/0 AWG Cu on a 150 A OCPD breaker (118.9 A continuous).

Alternative Inverter Comparison

Compare efficiency (95.47%) and MPPT window (350-600 V) directly against CSI Solar Co Ltd: CSI-100K-T480GL03-U {480V} (99,368 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for DYNAPOWER COMPANY LLC: MPS-100 {480V} by DYNAPOWER COMPANY LLC covering breaker sizing, MPPT limits, and 480 V, 3-phase interconnection.

What breaker and wire size does DYNAPOWER COMPANY LLC: MPS-100 {480V} require?

At 98,861 W continuous AC (480 V, 3-phase), continuous current is 118.9 A; 125% NEC 690.8/705.12 sizing requires a 150 A breaker and 1/0 AWG Cu (75 C) wire.

What commercial switchgear or feeder sizing does DYNAPOWER COMPANY LLC: MPS-100 {480V} require?

At 98,861 W AC and 480 V, 3-phase, continuous line current is 118.9 A, requiring a 150 A OCPD and 1,200A Bus / 1,200A Main (480V) or NEC 705.11 interconnection.

How does DYNAPOWER COMPANY LLC: MPS-100 {480V} compare to CSI Solar Co Ltd: CSI-100K-T480GL03-U {480V}?

DYNAPOWER COMPANY LLC: MPS-100 {480V} delivers 98,861 W AC at 95.47% CEC efficiency with a 600 V DC ceiling, while CSI Solar Co Ltd: CSI-100K-T480GL03-U {480V} outputs 99,368 W at 480 V, 3-phase.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.