Manufacturer: Chint Power Systems America Registry: CEC Verified Engineering Specification

Chint Power Systems America: CPS ECB625KTL-M/US-480 {480V} outputs 62,500 W AC at 480 V, 3-phase (75.2 A continuous, 100 A OCPD), ranking #647 of 2,343 CEC inverters at 97.36% efficiency with a 750-1,100 V MPPT window and 1,100 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
62,500 W
AC Voltage
480 V, 3-phase
Min PV Breaker
100 A (3 AWG Cu)
CEC Efficiency
97.36%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Chint Power Systems America: CPS ECB625KTL-M/US-480 {480V} Compare Against Peer CEC Listings?

How Chint Power Systems America Chint Power Systems America: CPS ECB625KTL-M/US-480 {480V} compares on 97.36% efficiency, MPPT span, and 120% busbar interconnection.

With a 750-1,100 V MPPT tracking band and 1,100 V DC ceiling, Chint Power Systems America: CPS ECB625KTL-M/US-480 {480V} handles 62,500 W continuous AC (12,500 W above the 50,000 W 480 V median). Commercial 480 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (480V) or NEC 705.11 supply-side tap. Installers comparing Chint Power Systems America against BYD Auto Industry Company Limited: BEG60KTL-U-R1 {480V} (60,276 W) should verify whether listed since 2025-06-23 grid-support firmware meets local IEEE 1547 utility rules.

Where Does Chint Power Systems America: CPS ECB625KTL-M/US-480 {480V} Fall Across Listed CEC Models?

Position of Chint Power Systems America: CPS ECB625KTL-M/US-480 {480V} (62,500 W AC) relative to the 7,680 W CEC median inverter.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where Chint Power Systems America: CPS ECB625KTL-M/US-480 {480V} (62,500 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACChint Power System: 62,500 W

What Dataset Percentiles Define Chint Power Systems America: CPS ECB625KTL-M/US-480 {480V}?

Percentile placement of Chint Power Systems America: CPS ECB625KTL-M/US-480 {480V} across AC power class, conversion efficiency, and backfeed breaker size.

Chint Power Systems America: CPS ECB625KTL-M/US-480 {480V} Technical ThresholdsPercentile comparison for Chint Power Systems America: CPS ECB625KTL-M/US-480 {480V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output62,500 WCEC Efficiency97.36%Backfeed Breaker100 A

What Do the Dataset Ranks Show for Chint Power Systems America: CPS ECB625KTL-M/US-480 {480V}?

Primary electrical sizing limits, efficiency ranks, and NEC 705.12 / 690.7 thresholds for Chint Power Systems America: CPS ECB625KTL-M/US-480 {480V}.

Eff #647 / 2,343

97.36% CEC Weighted Efficiency

-0.66 pts vs the 98.02% 480 V median; overall power rank #393 (62,500 W, top 16.8%; higher than 83.2% of peers).

NEC 705.12 Check

100 A Required Backfeed OCPD

125% x 75.2 A = 94.0 A -> 100 A standard OCPD using 3 AWG Cu (75 C).

MPPT Window

750 V - 1,100 V (Max 1,100 V DC)

Tracking span of 350.0 V; listed since 2025-06-23 (grid-tied PV inverter).

Commercial / 3-Phase Fit

Supply-Side Tap (705.11) / Dedicated Switchboard

Evaluated for 480 V, 3-phase switchgear (200A Bus / 200A Main (480V) to 1,200A Bus / 1,200A Main (480V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 62500.0W / 480 V 3-phase -> 75.2 A | Breaker >= 1.25 * 75.2 = 94.0 A -> 100 A

CEC Inverters.csv for Chint Power Systems America: CPS ECB625KTL-M/US-480 {480V}: Paco=62500.0 W, Vac=480 V, Vdcmax=1100.0 V, Eff=97.36%.

Result: Min 100 A breaker & 3 AWG Cu (75 C); 1,200A Bus / 1,200A Main (480V): PASS (120% Commercial Busbar).

What Are the Published CEC Specifications for Chint Power Systems America: CPS ECB625KTL-M/US-480 {480V}?

Official California Energy Commission electrical test parameters, AC voltage, and DC limits for Chint Power Systems America: CPS ECB625KTL-M/US-480 {480V}.

Official California Energy Commission (NREL SAM) test parameters for Chint Power Systems America: CPS ECB625KTL-M/US-480 {480V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 62,500 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 480 V, 3-phase 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 1,100 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 750 V - 1,100 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 69.3998 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 97.36% Calculated AC/DC conversion ratio from CEC test protocol
CEC Listing Date & Hybrid 2025-06-23 / Hybrid: No (Grid-Tied PV) Utility interconnection approval metadata

What Switchgear Limits Apply to Chint Power Systems America: CPS ECB625KTL-M/US-480 {480V} (480 V, 3-phase)?

Check whether Chint Power Systems America: CPS ECB625KTL-M/US-480 {480V} (100 A breaker) fits without main breaker derate or supply-side taps.

Evaluates Chint Power Systems America: CPS ECB625KTL-M/US-480 {480V} (100 A required OCPD at 480 V, 3-phase) across standard distribution busbars.
Switchboard / Interconnect120% Max BackfeedRequired PV OCPDCompliance Verdict
200A Bus / 200A Main (480V) 40 A 100 A Supply-Side Tap (705.11) / Dedicated Switchboard
400A Bus / 400A Main (480V) 80 A 100 A Supply-Side Tap (705.11) / Dedicated Switchboard
600A Bus / 600A Main (480V) 120 A 100 A PASS (120% Commercial Busbar)
800A Bus / 800A Main (480V) 160 A 100 A PASS (120% Commercial Busbar)
1,200A Bus / 1,200A Main (480V) 240 A 100 A PASS (120% Commercial Busbar)

Which CEC PV Module Strings Pair With Chint Power Systems America: CPS ECB625KTL-M/US-480 {480V}?

Verified cold-weather (-10 C) series module counts matched to Chint Power Systems America: CPS ECB625KTL-M/US-480 {480V}'s 1,100 V DC ceiling.

Sampled CEC PV modules aligned within 750.0-1100.0 V MPPT and 1100.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
AXITEC AC-590TGB/144TS 590.0 W 56.24 V 18 to 19 panels 11.21 kW
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 23 to 26 panels 11.44 kW
Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF 425.0 W 44.75 V 22 to 24 panels 10.2 kW
CSI Solar Co Ltd CS6P-200P 200.0 W 40.6 V 26 to 27 panels 5.4 kW

Which Competing Grid-Support Inverters Compare to Chint Power Systems America: CPS ECB625KTL-M/US-480 {480V}?

Alternative CEC inverters comparable to Chint Power Systems America: CPS ECB625KTL-M/US-480 {480V}, including BYD Auto Industry Company Limited: BEG60KTL-U-R1 {480V} (60,276 W) at 480 V, 3-phase.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
BYD Auto Industry Company Limited: BEG60KTL-U-R1 {480V}
BYD Auto Industry Company Limited
60,276 W -2224 W 480.0 V 950.0 V 95.69%
ABB: PVS-60-TL-R-US {480V}
ABB
60,033 W -2467 W 480.0 V 800.0 V 98.18%
ABB: PVS-60-TL-S-R-US {480V}
ABB
60,033 W -2467 W 480.0 V 800.0 V 98.18%
ABB: PVS-60-TL-S-US {480V}
ABB
60,033 W -2467 W 480.0 V 800.0 V 98.18%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for Chint Power Systems America: CPS ECB625KTL-M/US-480 {480V}?

Check Chint Power Systems America: CPS ECB625KTL-M/US-480 {480V} (62,500 W AC, 100 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Commercial 480 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (480V) or NEC 705.11 supply-side tap.
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 1,100 V DC on Chint Power Systems America: CPS ECB625KTL-M/US-480 {480V}.

Chint Power Systems America: CPS ECB625KTL-M/US-480 {480V} Panel & Wire Spec

Size 75 C copper conductors at 3 AWG Cu on a 100 A OCPD breaker (75.2 A continuous).

Alternative Inverter Comparison

Compare efficiency (97.36%) and MPPT window (750-1,100 V) directly against BYD Auto Industry Company Limited: BEG60KTL-U-R1 {480V} (60,276 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Chint Power Systems America: CPS ECB625KTL-M/US-480 {480V} by Chint Power Systems America covering breaker sizing, MPPT limits, and 480 V, 3-phase interconnection.

What breaker and wire size does Chint Power Systems America: CPS ECB625KTL-M/US-480 {480V} require?

At 62,500 W continuous AC (480 V, 3-phase), continuous current is 75.2 A; 125% NEC 690.8/705.12 sizing requires a 100 A breaker and 3 AWG Cu (75 C) wire.

What commercial switchgear or feeder sizing does Chint Power Systems America: CPS ECB625KTL-M/US-480 {480V} require?

At 62,500 W AC and 480 V, 3-phase, continuous line current is 75.2 A, requiring a 100 A OCPD and 1,200A Bus / 1,200A Main (480V) or NEC 705.11 interconnection.

How does Chint Power Systems America: CPS ECB625KTL-M/US-480 {480V} compare to BYD Auto Industry Company Limited: BEG60KTL-U-R1 {480V}?

Chint Power Systems America: CPS ECB625KTL-M/US-480 {480V} delivers 62,500 W AC at 97.36% CEC efficiency with a 1,100 V DC ceiling, while BYD Auto Industry Company Limited: BEG60KTL-U-R1 {480V} outputs 60,276 W at 480 V, 3-phase.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.