Skip to main content
WireAndSun
Calculators
CEC Grid-Support Inverter

BYD Auto Industry Company Limited: BEG60KTL-U-R1 {480V} — CEC Inverter Specifications

Manufacturer: BYD Auto Industry Company Limited Registry: CEC Verified Engineering Specification

BYD Auto Industry Company Limited: BEG60KTL-U-R1 {480V} outputs 60,276 W AC at 480 V, 3-phase (72.5 A continuous, 100 A OCPD), ranking #2,120 of 2,343 CEC inverters at 95.69% efficiency with a 750-950 V MPPT window and 950 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
60,276 W
AC Voltage
480 V, 3-phase
Min PV Breaker
100 A (3 AWG Cu)
CEC Efficiency
95.69%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does BYD Auto Industry Company Limited: BEG60KTL-U-R1 {480V} Compare Against Peer CEC Listings?

Breaker sizing (100 A), 3 AWG Cu wire rules, and DC input limits for BYD Auto Industry Company Limited: BEG60KTL-U-R1 {480V}.

For NEC 705.12 solar interconnection, BYD Auto Industry Company Limited: BEG60KTL-U-R1 {480V} outputs 72.5 A continuous AC at 480 V, 3-phase and needs a 100 A backfeed breaker on 3 AWG Cu (75 C). Commercial 480 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (480V) or NEC 705.11 supply-side tap. Conversion efficiency scores 95.69% (#2,120 of 2,343, -1.13 pts vs overall CEC median).

Where Does BYD Auto Industry Company Limited: BEG60KTL-U-R1 {480V} Fall Across Listed CEC Models?

Output power comparison showing where BYD Auto Industry Company Limited: BEG60KTL-U-R1 {480V} sits among all 2,343 CEC-listed grid-support inverters.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where BYD Auto Industry Company Limited: BEG60KTL-U-R1 {480V} (60,276 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACBYD Auto Industry : 60,276 W

What Dataset Percentiles Define BYD Auto Industry Company Limited: BEG60KTL-U-R1 {480V}?

Relative ranking of BYD Auto Industry Company Limited: BEG60KTL-U-R1 {480V} on continuous AC power, CEC weighted efficiency, and OCPD breaker current.

BYD Auto Industry Company Limited: BEG60KTL-U-R1 {480V} Technical ThresholdsPercentile comparison for BYD Auto Industry Company Limited: BEG60KTL-U-R1 {480V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output60,276 WCEC Efficiency95.69%Backfeed Breaker100 A

What Do the Dataset Ranks Show for BYD Auto Industry Company Limited: BEG60KTL-U-R1 {480V}?

Snapshot of BYD Auto Industry Company Limited: BEG60KTL-U-R1 {480V} efficiency rank (#2,120), OCPD breaker size, MPPT span, and busbar verdict.

Eff #2,120 / 2,343

95.69% CEC Weighted Efficiency

-2.33 pts vs the 98.02% 480 V median; overall power rank #397 (60,276 W, top 16.9%; higher than 83.1% of peers).

NEC 705.12 Check

100 A Required Backfeed OCPD

125% x 72.5 A = 90.6 A -> 100 A standard OCPD using 3 AWG Cu (75 C).

MPPT Window

750 V - 950 V (Max 950 V DC)

Tracking span of 200.0 V; listed since 2023-02-01 (grid-tied PV inverter).

Commercial / 3-Phase Fit

Supply-Side Tap (705.11) / Dedicated Switchboard

Evaluated for 480 V, 3-phase switchgear (200A Bus / 200A Main (480V) to 1,200A Bus / 1,200A Main (480V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 60276.0W / 480 V 3-phase -> 72.5 A | Breaker >= 1.25 * 72.5 = 90.6 A -> 100 A

CEC Inverters.csv for BYD Auto Industry Company Limited: BEG60KTL-U-R1 {480V}: Paco=60276.0 W, Vac=480 V, Vdcmax=950.0 V, Eff=95.69%.

Result: Min 100 A breaker & 3 AWG Cu (75 C); 1,200A Bus / 1,200A Main (480V): PASS (120% Commercial Busbar).

What Are the Published CEC Specifications for BYD Auto Industry Company Limited: BEG60KTL-U-R1 {480V}?

Complete California Energy Commission grid-support inverter ratings and hybrid battery capabilities for BYD Auto Industry Company Limited: BEG60KTL-U-R1 {480V}.

Official California Energy Commission (NREL SAM) test parameters for BYD Auto Industry Company Limited: BEG60KTL-U-R1 {480V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 60,276 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 480 V, 3-phase 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 950 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 750 V - 950 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 74.1106 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 95.69% Calculated AC/DC conversion ratio from CEC test protocol
CEC Listing Date & Hybrid 2023-02-01 / Hybrid: No (Grid-Tied PV) Utility interconnection approval metadata

What Switchgear Limits Apply to BYD Auto Industry Company Limited: BEG60KTL-U-R1 {480V} (480 V, 3-phase)?

NEC 705.12(B)(3)(2) backfeed compliance table for BYD Auto Industry Company Limited: BEG60KTL-U-R1 {480V} at 480 V, 3-phase.

Evaluates BYD Auto Industry Company Limited: BEG60KTL-U-R1 {480V} (100 A required OCPD at 480 V, 3-phase) across standard distribution busbars.
Switchboard / Interconnect120% Max BackfeedRequired PV OCPDCompliance Verdict
200A Bus / 200A Main (480V) 40 A 100 A Supply-Side Tap (705.11) / Dedicated Switchboard
400A Bus / 400A Main (480V) 80 A 100 A Supply-Side Tap (705.11) / Dedicated Switchboard
600A Bus / 600A Main (480V) 120 A 100 A PASS (120% Commercial Busbar)
800A Bus / 800A Main (480V) 160 A 100 A PASS (120% Commercial Busbar)
1,200A Bus / 1,200A Main (480V) 240 A 100 A PASS (120% Commercial Busbar)

Which Competing Grid-Support Inverters Compare to BYD Auto Industry Company Limited: BEG60KTL-U-R1 {480V}?

Peer 480 V, 3-phase CEC inverters near 60,276 W AC output such as ABB: PVS-60-TL-R-US {480V}. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
ABB: PVS-60-TL-R-US {480V}
ABB
60,033 W -243 W 480.0 V 800.0 V 98.18%
ABB: PVS-60-TL-S-R-US {480V}
ABB
60,033 W -243 W 480.0 V 800.0 V 98.18%
ABB: PVS-60-TL-S-US {480V}
ABB
60,033 W -243 W 480.0 V 800.0 V 98.18%
ABB: PVS-60-TL-SC-R-US {480V}
ABB
60,033 W -243 W 480.0 V 800.0 V 98.18%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for BYD Auto Industry Company Limited: BEG60KTL-U-R1 {480V}?

Check BYD Auto Industry Company Limited: BEG60KTL-U-R1 {480V} (60,276 W AC, 100 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Commercial 480 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (480V) or NEC 705.11 supply-side tap.
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 950 V DC on BYD Auto Industry Company Limited: BEG60KTL-U-R1 {480V}.

BYD Auto Industry Company Limited: BEG60KTL-U-R1 {480V} Panel & Wire Spec

Size 75 C copper conductors at 3 AWG Cu on a 100 A OCPD breaker (72.5 A continuous).

Alternative Inverter Comparison

Compare efficiency (95.69%) and MPPT window (750-950 V) directly against ABB: PVS-60-TL-R-US {480V} (60,033 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for BYD Auto Industry Company Limited: BEG60KTL-U-R1 {480V} by BYD Auto Industry Company Limited covering breaker sizing, MPPT limits, and 480 V, 3-phase interconnection.

What breaker and wire size does BYD Auto Industry Company Limited: BEG60KTL-U-R1 {480V} require?

At 60,276 W continuous AC (480 V, 3-phase), continuous current is 72.5 A; 125% NEC 690.8/705.12 sizing requires a 100 A breaker and 3 AWG Cu (75 C) wire.

What commercial switchgear or feeder sizing does BYD Auto Industry Company Limited: BEG60KTL-U-R1 {480V} require?

At 60,276 W AC and 480 V, 3-phase, continuous line current is 72.5 A, requiring a 100 A OCPD and 1,200A Bus / 1,200A Main (480V) or NEC 705.11 interconnection.

How does BYD Auto Industry Company Limited: BEG60KTL-U-R1 {480V} compare to ABB: PVS-60-TL-R-US {480V}?

BYD Auto Industry Company Limited: BEG60KTL-U-R1 {480V} delivers 60,276 W AC at 95.69% CEC efficiency with a 950 V DC ceiling, while ABB: PVS-60-TL-R-US {480V} outputs 60,033 W at 480 V, 3-phase.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.