Skip to main content
WireAndSun
Calculators
CEC Grid-Support Inverter

Altenergy Power System Inc: QT2-480 {480V} — CEC Inverter Specifications

Manufacturer: Altenergy Power System Inc Registry: CEC Verified Engineering Specification

Altenergy Power System Inc: QT2-480 {480V} outputs 1,821 W AC at 480 V, 3-phase (2.2 A continuous, 15 A OCPD), ranking #1,948 of 2,343 CEC inverters at 96.02% efficiency with a 34-42 V MPPT window and 42 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
1,821 W
AC Voltage
480 V, 3-phase
Min PV Breaker
15 A (14 AWG Cu)
CEC Efficiency
96.02%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Altenergy Power System Inc: QT2-480 {480V} Compare Against Peer CEC Listings?

Breaker sizing (15 A), 14 AWG Cu wire rules, and DC input limits for Altenergy Power System Inc: QT2-480 {480V}.

For NEC 705.12 solar interconnection, Altenergy Power System Inc: QT2-480 {480V} outputs 2.2 A continuous AC at 480 V, 3-phase and needs a 15 A backfeed breaker on 14 AWG Cu (75 C). Commercial 480 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (480V) or NEC 705.11 supply-side tap. Conversion efficiency scores 96.02% (#1,948 of 2,343, -0.80 pts vs overall CEC median).

Where Does Altenergy Power System Inc: QT2-480 {480V} Fall Across Listed CEC Models?

Output power comparison showing where Altenergy Power System Inc: QT2-480 {480V} sits among all 2,343 CEC-listed grid-support inverters.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where Altenergy Power System Inc: QT2-480 {480V} (1,821 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACAltenergy Power Sy: 1,821 W

What Dataset Percentiles Define Altenergy Power System Inc: QT2-480 {480V}?

Relative ranking of Altenergy Power System Inc: QT2-480 {480V} on continuous AC power, CEC weighted efficiency, and OCPD breaker current.

Altenergy Power System Inc: QT2-480 {480V} Technical ThresholdsPercentile comparison for Altenergy Power System Inc: QT2-480 {480V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output1,821 WCEC Efficiency96.02%Backfeed Breaker15 A

What Do the Dataset Ranks Show for Altenergy Power System Inc: QT2-480 {480V}?

Snapshot of Altenergy Power System Inc: QT2-480 {480V} efficiency rank (#1,948), OCPD breaker size, MPPT span, and busbar verdict.

Eff #1,948 / 2,343

96.02% CEC Weighted Efficiency

-2.00 pts vs the 98.02% 480 V median; overall power rank #1,770 (1,821 W, below CEC median; higher than 24.4% of peers).

NEC 705.12 Check

15 A Required Backfeed OCPD

125% x 2.2 A = 2.8 A -> 15 A standard OCPD using 14 AWG Cu (75 C).

MPPT Window

34 V - 42 V (Max 42 V DC)

Tracking span of 8.0 V; listed since 2023-05-11 (grid-tied PV inverter).

Commercial / 3-Phase Fit

PASS (120% Commercial Busbar)

Evaluated for 480 V, 3-phase switchgear (200A Bus / 200A Main (480V) to 1,200A Bus / 1,200A Main (480V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 1821.0W / 480 V 3-phase -> 2.2 A | Breaker >= 1.25 * 2.2 = 2.8 A -> 15 A

CEC Inverters.csv for Altenergy Power System Inc: QT2-480 {480V}: Paco=1821.0 W, Vac=480 V, Vdcmax=42.0 V, Eff=96.02%.

Result: Min 15 A breaker & 14 AWG Cu (75 C); 1,200A Bus / 1,200A Main (480V): PASS (120% Commercial Busbar).

What Are the Published CEC Specifications for Altenergy Power System Inc: QT2-480 {480V}?

Complete California Energy Commission grid-support inverter ratings and hybrid battery capabilities for Altenergy Power System Inc: QT2-480 {480V}.

Official California Energy Commission (NREL SAM) test parameters for Altenergy Power System Inc: QT2-480 {480V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 1,821 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 480 V, 3-phase 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 42 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 34 V - 42 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 49.9063 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 96.02% Calculated AC/DC conversion ratio from CEC test protocol
CEC Listing Date & Hybrid 2023-05-11 / Hybrid: No (Grid-Tied PV) Utility interconnection approval metadata

What Switchgear Limits Apply to Altenergy Power System Inc: QT2-480 {480V} (480 V, 3-phase)?

NEC 705.12(B)(3)(2) backfeed compliance table for Altenergy Power System Inc: QT2-480 {480V} at 480 V, 3-phase.

Evaluates Altenergy Power System Inc: QT2-480 {480V} (15 A required OCPD at 480 V, 3-phase) across standard distribution busbars.
Switchboard / Interconnect120% Max BackfeedRequired PV OCPDCompliance Verdict
200A Bus / 200A Main (480V) 40 A 15 A PASS (120% Commercial Busbar)
400A Bus / 400A Main (480V) 80 A 15 A PASS (120% Commercial Busbar)
600A Bus / 600A Main (480V) 120 A 15 A PASS (120% Commercial Busbar)
800A Bus / 800A Main (480V) 160 A 15 A PASS (120% Commercial Busbar)
1,200A Bus / 1,200A Main (480V) 240 A 15 A PASS (120% Commercial Busbar)

Which CEC PV Module Strings Pair With Altenergy Power System Inc: QT2-480 {480V}?

Minimum and maximum series solar module strings fitting Altenergy Power System Inc: QT2-480 {480V} MPPT and 42 V limits.

Sampled CEC PV modules aligned within 34.0-42.0 V MPPT and 42.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
CSI Solar Co Ltd CS6P-200P 200.0 W 40.6 V 1 panel (micro/module) 0.2 kW

Which Competing Grid-Support Inverters Compare to Altenergy Power System Inc: QT2-480 {480V}?

Peer 480 V, 3-phase CEC inverters near 1,821 W AC output such as Fronius International GmbH: Fronius Symo 100-3 480 {480V}.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
Fronius International GmbH: Fronius Symo 100-3 480 {480V}
Fronius International GmbH
9,995 W +8174 W 480.0 V 800.0 V 97.42%
Fronius International GmbH: Fronius Symo 125-3 480 {480V}
Fronius International GmbH
12,500 W +10679 W 480.0 V 800.0 V 97.57%
Fronius International GmbH: Fronius Symo 150-3 480 {480V}
Fronius International GmbH
15,000 W +13179 W 480.0 V 800.0 V 97.47%
Fronius International GmbH: Fronius Symo Advanced 150-3 480 {480V}
Fronius International GmbH
15,197 W +13376 W 480.0 V 800.0 V 97.48%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for Altenergy Power System Inc: QT2-480 {480V}?

Check Altenergy Power System Inc: QT2-480 {480V} (1,821 W AC, 15 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Commercial 480 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (480V) or NEC 705.11 supply-side tap.
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 42 V DC on Altenergy Power System Inc: QT2-480 {480V}.

Altenergy Power System Inc: QT2-480 {480V} Panel & Wire Spec

Size 75 C copper conductors at 14 AWG Cu on a 15 A OCPD breaker (2.2 A continuous).

Alternative Inverter Comparison

Compare efficiency (96.02%) and MPPT window (34-42 V) directly against Fronius International GmbH: Fronius Symo 100-3 480 {480V} (9,995 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Altenergy Power System Inc: QT2-480 {480V} by Altenergy Power System Inc covering breaker sizing, MPPT limits, and 480 V, 3-phase interconnection.

What breaker and wire size does Altenergy Power System Inc: QT2-480 {480V} require?

At 1,821 W continuous AC (480 V, 3-phase), continuous current is 2.2 A; 125% NEC 690.8/705.12 sizing requires a 15 A breaker and 14 AWG Cu (75 C) wire.

What commercial switchgear or feeder sizing does Altenergy Power System Inc: QT2-480 {480V} require?

At 1,821 W AC and 480 V, 3-phase, continuous line current is 2.2 A, requiring a 15 A OCPD and 1,200A Bus / 1,200A Main (480V) or NEC 705.11 interconnection.

How does Altenergy Power System Inc: QT2-480 {480V} compare to Fronius International GmbH: Fronius Symo 100-3 480 {480V}?

Altenergy Power System Inc: QT2-480 {480V} delivers 1,821 W AC at 96.02% CEC efficiency with a 42 V DC ceiling, while Fronius International GmbH: Fronius Symo 100-3 480 {480V} outputs 9,995 W at 480 V, 3-phase.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.