Manufacturer: ABB Registry: CEC Verified Engineering Specification

ABB: PVI-38-OUTD-S-US-A {277V} outputs 3,800 W AC at 480Y/277 V, 3-phase (4.6 A continuous, 15 A OCPD), ranking #1,315 of 2,343 CEC inverters at 96.64% efficiency with a 100-480 V MPPT window and 480 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
3,800 W
AC Voltage
480Y/277 V, 3-phase
Min PV Breaker
15 A (14 AWG Cu)
CEC Efficiency
96.64%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does ABB: PVI-38-OUTD-S-US-A {277V} Compare Against Peer CEC Listings?

NEC 705.12 breaker requirements, efficiency placement, and 480Y/277 V, 3-phase grid-support overview for ABB: PVI-38-OUTD-S-US-A {277V}. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Ranking #1,650 of 2,343 CEC inverters (below CEC median; higher than 28.7% of peers), ABB: PVI-38-OUTD-S-US-A {277V} is a grid-tied PV inverter delivering 3,800 W continuous AC at 480Y/277 V, 3-phase (4.6 A continuous). Commercial 480Y/277 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (277V) or NEC 705.11 supply-side tap. Weighted CEC efficiency reaches 96.64% (-0.18 pts vs the 96.82% 277 V median) against peers like Shenzhen Growatt New Energy Co Ltd: GROWATT 4000MTLP-US {277V} (4,060 W).

Where Does ABB: PVI-38-OUTD-S-US-A {277V} Fall Across Listed CEC Models?

Marks ABB: PVI-38-OUTD-S-US-A {277V} (3,800 W AC) across the California Energy Commission inverter AC capacity distribution. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where ABB: PVI-38-OUTD-S-US-A {277V} (3,800 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACABB: PVI-38-OUTD-S: 3,800 W

What Dataset Percentiles Define ABB: PVI-38-OUTD-S-US-A {277V}?

Benchmarks ABB: PVI-38-OUTD-S-US-A {277V} continuous AC output, 96.64% CEC weighted efficiency, and 15 A OCPD breaker demand. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

ABB: PVI-38-OUTD-S-US-A {277V} Technical ThresholdsPercentile comparison for ABB: PVI-38-OUTD-S-US-A {277V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output3,800 WCEC Efficiency96.64%Backfeed Breaker15 A

What Do the Dataset Ranks Show for ABB: PVI-38-OUTD-S-US-A {277V}?

Four key NEC 705.12 and California Energy Commission metrics defining ABB: PVI-38-OUTD-S-US-A {277V} by ABB. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Eff #1,315 / 2,343

96.64% CEC Weighted Efficiency

-0.18 pts vs the 96.82% 277 V median; overall power rank #1,650 (3,800 W, below CEC median; higher than 28.7% of peers).

NEC 705.12 Check

15 A Required Backfeed OCPD

125% x 4.6 A = 5.8 A -> 15 A standard OCPD using 14 AWG Cu (75 C).

MPPT Window

100 V - 480 V (Max 480 V DC)

Tracking span of 380.0 V; listed since 2018-10-15 (grid-tied PV inverter).

Commercial / 3-Phase Fit

PASS (120% Commercial Busbar)

Evaluated for 480Y/277 V, 3-phase switchgear (200A Bus / 200A Main (277V) to 1,200A Bus / 1,200A Main (277V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 3800.0W / 480 V 3-phase -> 4.6 A | Breaker >= 1.25 * 4.6 = 5.8 A -> 15 A

CEC Inverters.csv for ABB: PVI-38-OUTD-S-US-A {277V}: Paco=3800.0 W, Vac=277 V, Vdcmax=480.0 V, Eff=96.64%.

Result: Min 15 A breaker & 14 AWG Cu (75 C); 1,200A Bus / 1,200A Main (277V): PASS (120% Commercial Busbar).

What Are the Published CEC Specifications for ABB: PVI-38-OUTD-S-US-A {277V}?

Official laboratory CEC ratings, MPPT operating window, and DC voltage bounds recorded for ABB: PVI-38-OUTD-S-US-A {277V}. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Official California Energy Commission (NREL SAM) test parameters for ABB: PVI-38-OUTD-S-US-A {277V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 3,800 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 480Y/277 V, 3-phase 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 480 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 100 V - 480 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 9.95425 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 96.64% Calculated AC/DC conversion ratio from CEC test protocol
CEC Listing Date & Hybrid 2018-10-15 / Hybrid: No (Grid-Tied PV) Utility interconnection approval metadata

What Switchgear Limits Apply to ABB: PVI-38-OUTD-S-US-A {277V} (480Y/277 V, 3-phase)?

Evaluates ABB: PVI-38-OUTD-S-US-A {277V} (15 A OCPD) across standard 100 A to 225 A busbars or commercial switchboards.

Evaluates ABB: PVI-38-OUTD-S-US-A {277V} (15 A required OCPD at 480Y/277 V, 3-phase) across standard distribution busbars.
Switchboard / Interconnect120% Max BackfeedRequired PV OCPDCompliance Verdict
200A Bus / 200A Main (277V) 40 A 15 A PASS (120% Commercial Busbar)
400A Bus / 400A Main (277V) 80 A 15 A PASS (120% Commercial Busbar)
600A Bus / 600A Main (277V) 120 A 15 A PASS (120% Commercial Busbar)
800A Bus / 800A Main (277V) 160 A 15 A PASS (120% Commercial Busbar)
1,200A Bus / 1,200A Main (277V) 240 A 15 A PASS (120% Commercial Busbar)

Which CEC PV Module Strings Pair With ABB: PVI-38-OUTD-S-US-A {277V}?

Sample PV string lengths aligned within 100-480 V MPPT and 480 V DC max at -10 C. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Sampled CEC PV modules aligned within 100.0-480.0 V MPPT and 480.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
AXITEC AC-590TGB/144TS 590.0 W 56.24 V 3 to 8 panels 4.72 kW
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 3 to 11 panels 4.84 kW
Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF 425.0 W 44.75 V 3 to 10 panels 4.25 kW
CSI Solar Co Ltd CS6P-200P 200.0 W 40.6 V 4 to 11 panels 2.2 kW

Which Competing Grid-Support Inverters Compare to ABB: PVI-38-OUTD-S-US-A {277V}?

Competing CEC grid-support inverters near 3,800 W AC and 480Y/277 V, 3-phase, led by Shenzhen Growatt New Energy Co Ltd: GROWATT 4000MTLP-US {277V}.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
Shenzhen Growatt New Energy Co Ltd: GROWATT 4000MTLP-US {277V}
Shenzhen Growatt New Energy Co Ltd
4,060 W +260 W 277.0 V 550.0 V 97.23%
Shenzhen Growatt New Energy Co Ltd: GROWATT 5000MTLP-US {277V}
Shenzhen Growatt New Energy Co Ltd
5,060 W +1260 W 277.0 V 550.0 V 97.1%
Shenzhen Growatt New Energy Co Ltd: GROWATT 6000MTLP-US {277V}
Shenzhen Growatt New Energy Co Ltd
6,080 W +2280 W 277.0 V 550.0 V 97.0%
Northern Electric & Power Co Ltd: BDM-800-277A {277V}
Northern Electric & Power Co Ltd
799 W -3001 W 277.0 V 55.0 V 96.31%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for ABB: PVI-38-OUTD-S-US-A {277V}?

Check ABB: PVI-38-OUTD-S-US-A {277V} (3,800 W AC, 15 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Commercial 480Y/277 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (277V) or NEC 705.11 supply-side tap.
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 480 V DC on ABB: PVI-38-OUTD-S-US-A {277V}.

ABB: PVI-38-OUTD-S-US-A {277V} Panel & Wire Spec

Size 75 C copper conductors at 14 AWG Cu on a 15 A OCPD breaker (4.6 A continuous).

Alternative Inverter Comparison

Compare efficiency (96.64%) and MPPT window (100-480 V) directly against Shenzhen Growatt New Energy Co Ltd: GROWATT 4000MTLP-US {277V} (4,060 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for ABB: PVI-38-OUTD-S-US-A {277V} by ABB covering breaker sizing, MPPT limits, and 480Y/277 V, 3-phase interconnection.

What breaker and wire size does ABB: PVI-38-OUTD-S-US-A {277V} require?

At 3,800 W continuous AC (480Y/277 V, 3-phase), continuous current is 4.6 A; 125% NEC 690.8/705.12 sizing requires a 15 A breaker and 14 AWG Cu (75 C) wire.

What commercial switchgear or feeder sizing does ABB: PVI-38-OUTD-S-US-A {277V} require?

At 3,800 W AC and 480Y/277 V, 3-phase, continuous line current is 4.6 A, requiring a 15 A OCPD and 1,200A Bus / 1,200A Main (277V) or NEC 705.11 interconnection.

How does ABB: PVI-38-OUTD-S-US-A {277V} compare to Shenzhen Growatt New Energy Co Ltd: GROWATT 4000MTLP-US {277V}?

ABB: PVI-38-OUTD-S-US-A {277V} delivers 3,800 W AC at 96.64% CEC efficiency with a 480 V DC ceiling, while Shenzhen Growatt New Energy Co Ltd: GROWATT 4000MTLP-US {277V} outputs 4,060 W at 480Y/277 V, 3-phase.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.