Skip to main content
WireAndSun
Calculators
CEC Grid-Support Inverter

Shenzhen Growatt New Energy Co Ltd: GROWATT 4000MTLP-US {277V} — CEC Inverter Specifications

Manufacturer: Shenzhen Growatt New Energy Co Ltd Registry: CEC Verified Engineering Specification

Shenzhen Growatt New Energy Co Ltd: GROWATT 4000MTLP-US {277V} outputs 4,060 W AC at 480Y/277 V, 3-phase (4.9 A continuous, 15 A OCPD), ranking #743 of 2,343 CEC inverters at 97.23% efficiency with a 100-550 V MPPT window and 550 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
4,060 W
AC Voltage
480Y/277 V, 3-phase
Min PV Breaker
15 A (14 AWG Cu)
CEC Efficiency
97.23%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Shenzhen Growatt New Energy Co Ltd: GROWATT 4000MTLP-US {277V} Compare Against Peer CEC Listings?

How Shenzhen Growatt New Energy Co Ltd Shenzhen Growatt New Energy Co Ltd: GROWATT 4000MTLP-US {277V} compares on 97.23% efficiency, MPPT span, and 120% busbar interconnection.

Shenzhen Growatt New Energy Co Ltd certifies Shenzhen Growatt New Energy Co Ltd: GROWATT 4000MTLP-US {277V} (grid-tied PV inverter, listed since 2019-01-15) at 4,060 W AC (1,940 W below the 6,000 W 277 V median). Its 550 V DC ceiling pairs with an MPPT window of 100-550 V (span 450.0 V). Under NEC 690.8/705.12, 125% sizing demands 14 AWG Cu conductors on a 15 A OCPD.

Where Does Shenzhen Growatt New Energy Co Ltd: GROWATT 4000MTLP-US {277V} Fall Across Listed CEC Models?

Position of Shenzhen Growatt New Energy Co Ltd: GROWATT 4000MTLP-US {277V} (4,060 W AC) relative to the 7,680 W CEC median inverter.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where Shenzhen Growatt New Energy Co Ltd: GROWATT 4000MTLP-US {277V} (4,060 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACShenzhen Growatt N: 4,060 W

What Dataset Percentiles Define Shenzhen Growatt New Energy Co Ltd: GROWATT 4000MTLP-US {277V}?

Percentile placement of Shenzhen Growatt New Energy Co Ltd: GROWATT 4000MTLP-US {277V} across AC power class, conversion efficiency, and backfeed breaker size.

Shenzhen Growatt New Energy Co Ltd: GROWATT 4000MTLP-US {277V} Technical ThresholdsPercentile comparison for Shenzhen Growatt New Energy Co Ltd: GROWATT 4000MTLP-US {277V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output4,060 WCEC Efficiency97.23%Backfeed Breaker15 A

What Do the Dataset Ranks Show for Shenzhen Growatt New Energy Co Ltd: GROWATT 4000MTLP-US {277V}?

Primary electrical sizing limits, efficiency ranks, and NEC 705.12 / 690.7 thresholds for Shenzhen Growatt New Energy Co Ltd: GROWATT 4000MTLP-US {277V}.

Eff #743 / 2,343

97.23% CEC Weighted Efficiency

+0.41 pts vs the 96.82% 277 V median; overall power rank #1,621 (4,060 W, below CEC median; higher than 30.8% of peers).

NEC 705.12 Check

15 A Required Backfeed OCPD

125% x 4.9 A = 6.1 A -> 15 A standard OCPD using 14 AWG Cu (75 C).

MPPT Window

100 V - 550 V (Max 550 V DC)

Tracking span of 450.0 V; listed since 2019-01-15 (grid-tied PV inverter).

Commercial / 3-Phase Fit

PASS (120% Commercial Busbar)

Evaluated for 480Y/277 V, 3-phase switchgear (200A Bus / 200A Main (277V) to 1,200A Bus / 1,200A Main (277V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 4060.0W / 480 V 3-phase -> 4.9 A | Breaker >= 1.25 * 4.9 = 6.1 A -> 15 A

CEC Inverters.csv for Shenzhen Growatt New Energy Co Ltd: GROWATT 4000MTLP-US {277V}: Paco=4060.0 W, Vac=277 V, Vdcmax=550.0 V, Eff=97.23%.

Result: Min 15 A breaker & 14 AWG Cu (75 C); 1,200A Bus / 1,200A Main (277V): PASS (120% Commercial Busbar).

What Are the Published CEC Specifications for Shenzhen Growatt New Energy Co Ltd: GROWATT 4000MTLP-US {277V}?

Official California Energy Commission electrical test parameters, AC voltage, and DC limits for Shenzhen Growatt New Energy Co Ltd: GROWATT 4000MTLP-US {277V}.

Official California Energy Commission (NREL SAM) test parameters for Shenzhen Growatt New Energy Co Ltd: GROWATT 4000MTLP-US {277V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 4,060 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 480Y/277 V, 3-phase 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 550 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 100 V - 550 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 8.66346 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 97.23% Calculated AC/DC conversion ratio from CEC test protocol
CEC Listing Date & Hybrid 2019-01-15 / Hybrid: No (Grid-Tied PV) Utility interconnection approval metadata

What Switchgear Limits Apply to Shenzhen Growatt New Energy Co Ltd: GROWATT 4000MTLP-US {277V} (480Y/277 V, 3-phase)?

Check whether Shenzhen Growatt New Energy Co Ltd: GROWATT 4000MTLP-US {277V} (15 A breaker) fits without main breaker derate or supply-side taps.

Evaluates Shenzhen Growatt New Energy Co Ltd: GROWATT 4000MTLP-US {277V} (15 A required OCPD at 480Y/277 V, 3-phase) across standard distribution busbars.
Switchboard / Interconnect120% Max BackfeedRequired PV OCPDCompliance Verdict
200A Bus / 200A Main (277V) 40 A 15 A PASS (120% Commercial Busbar)
400A Bus / 400A Main (277V) 80 A 15 A PASS (120% Commercial Busbar)
600A Bus / 600A Main (277V) 120 A 15 A PASS (120% Commercial Busbar)
800A Bus / 800A Main (277V) 160 A 15 A PASS (120% Commercial Busbar)
1,200A Bus / 1,200A Main (277V) 240 A 15 A PASS (120% Commercial Busbar)

Which CEC PV Module Strings Pair With Shenzhen Growatt New Energy Co Ltd: GROWATT 4000MTLP-US {277V}?

Verified cold-weather (-10 C) series module counts matched to Shenzhen Growatt New Energy Co Ltd: GROWATT 4000MTLP-US {277V}'s 550 V DC ceiling.

Sampled CEC PV modules aligned within 100.0-550.0 V MPPT and 550.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
AXITEC AC-590TGB/144TS 590.0 W 56.24 V 3 to 9 panels 5.31 kW
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 3 to 13 panels 5.72 kW
Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF 425.0 W 44.75 V 3 to 12 panels 5.1 kW
CSI Solar Co Ltd CS6P-200P 200.0 W 40.6 V 4 to 13 panels 2.6 kW

Which Competing Grid-Support Inverters Compare to Shenzhen Growatt New Energy Co Ltd: GROWATT 4000MTLP-US {277V}?

Alternative CEC inverters comparable to Shenzhen Growatt New Energy Co Ltd: GROWATT 4000MTLP-US {277V}, including ABB: PVI-42-OUTD-S-US-A {277V} (4,200 W) at 480Y/277 V, 3-phase.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
ABB: PVI-42-OUTD-S-US-A {277V}
ABB
4,200 W +140 W 277.0 V 480.0 V 96.62%
ABB: PVI-42-OUTD-S-US-Z-A {277V}
ABB
4,200 W +140 W 277.0 V 480.0 V 96.62%
ABB: PVI-42-OUTD-S-US-Z-M-A {277V}
ABB
4,200 W +140 W 277.0 V 480.0 V 96.62%
ABB: PVI-38-OUTD-S-US-A {277V}
ABB
3,800 W -260 W 277.0 V 480.0 V 96.64%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for Shenzhen Growatt New Energy Co Ltd: GROWATT 4000MTLP-US {277V}?

Check Shenzhen Growatt New Energy Co Ltd: GROWATT 4000MTLP-US {277V} (4,060 W AC, 15 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Commercial 480Y/277 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (277V) or NEC 705.11 supply-side tap.
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 550 V DC on Shenzhen Growatt New Energy Co Ltd: GROWATT 4000MTLP-US {277V}.

Shenzhen Growatt New Energy Co Ltd: GROWATT 4000MTLP-US {277V} Panel & Wire Spec

Size 75 C copper conductors at 14 AWG Cu on a 15 A OCPD breaker (4.9 A continuous).

Alternative Inverter Comparison

Compare efficiency (97.23%) and MPPT window (100-550 V) directly against ABB: PVI-42-OUTD-S-US-A {277V} (4,200 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Shenzhen Growatt New Energy Co Ltd: GROWATT 4000MTLP-US {277V} by Shenzhen Growatt New Energy Co Ltd covering breaker sizing, MPPT limits, and 480Y/277 V, 3-phase interconnection.

What breaker and wire size does Shenzhen Growatt New Energy Co Ltd: GROWATT 4000MTLP-US {277V} require?

At 4,060 W continuous AC (480Y/277 V, 3-phase), continuous current is 4.9 A; 125% NEC 690.8/705.12 sizing requires a 15 A breaker and 14 AWG Cu (75 C) wire.

What commercial switchgear or feeder sizing does Shenzhen Growatt New Energy Co Ltd: GROWATT 4000MTLP-US {277V} require?

At 4,060 W AC and 480Y/277 V, 3-phase, continuous line current is 4.9 A, requiring a 15 A OCPD and 1,200A Bus / 1,200A Main (277V) or NEC 705.11 interconnection.

How does Shenzhen Growatt New Energy Co Ltd: GROWATT 4000MTLP-US {277V} compare to ABB: PVI-42-OUTD-S-US-A {277V}?

Shenzhen Growatt New Energy Co Ltd: GROWATT 4000MTLP-US {277V} delivers 4,060 W AC at 97.23% CEC efficiency with a 550 V DC ceiling, while ABB: PVI-42-OUTD-S-US-A {277V} outputs 4,200 W at 480Y/277 V, 3-phase.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.