Skip to main content
WireAndSun
Calculators
CEC PV Module

ZNSHINE PV-TECH Co Ltd ZXP6-60-235/P — CEC Solar Module Specifications

Manufacturer: ZNSHINE PV-TECH Co Ltd Registry: CEC Verified Engineering Specification

ZNSHINE PV-TECH Co Ltd ZXP6-60-235/P is a 235.0 W STC (210.7 W PTC) Mono-c-Si solar module ranking #20,368 of 21,677 CEC listings (below all-CEC median; higher than 5.4% of peers). It delivers 14.36% efficiency, 37.38 V Voc at 25 C, and 41.7 V cold Voc at -10 C (14 panels max per 600 V string).

STC Wattage
235.0 W
PTC Wattage
210.7 W
Voc @ 25C
37.38 V
Efficiency
14.36%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does ZNSHINE PV-TECH Co Ltd ZXP6-60-235/P Compare Against Peer CEC Listings?

Solar engineering breakdown for ZNSHINE PV-TECH Co Ltd ZXP6-60-235/P: PTC thermal retention, roof footprint, and cold Voc string bounds.

Across 5,889 Mono-c-Si listings from ZNSHINE PV-TECH Co Ltd and peers, ZNSHINE PV-TECH Co Ltd ZXP6-60-235/P stands 175.0 W below the 410.0 W Mono-c-Si median and typical 89.7% PTC-to-STC thermal output (210.7 W real-world rating). Sizing 6 kW (26 panels) to 10 kW (43 panels) yields $1,529-$2,530/yr in baseline US bill offset. Lower 37.38 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters.

Where Does ZNSHINE PV-TECH Co Ltd ZXP6-60-235/P Fall Across Listed CEC Models?

Distribution marker showing ZNSHINE PV-TECH Co Ltd ZXP6-60-235/P (235.0 W) relative to the 385.0 W all-CEC solar panel median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where ZNSHINE PV-TECH Co Ltd ZXP6-60-235/P (235.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCZNSHINE PV-TECH Co: 235.0 W

What Dataset Percentiles Define ZNSHINE PV-TECH Co Ltd ZXP6-60-235/P?

Dataset percentiles tracking ZNSHINE PV-TECH Co Ltd ZXP6-60-235/P power output, thermal retention ratio, and aperture efficiency against 21,677 models.

ZNSHINE PV-TECH Co Ltd ZXP6-60-235/P Engineering BenchmarksPercentile comparison of ZNSHINE PV-TECH Co Ltd ZXP6-60-235/P wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage235.0 WPTC/STC Retention89.7%Module Efficiency14.36%

What Do the Dataset Ranks Show for ZNSHINE PV-TECH Co Ltd ZXP6-60-235/P?

Benchmark highlights for ZNSHINE PV-TECH Co Ltd ZXP6-60-235/P covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #20,368 / 21,677

235.0 W STC · Higher Than 5.4%

235.0 W STC (-150.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #20,560

14.36% Aperture Efficiency

Power density 143.6 W/m2 (5.55 percentage points below 19.91% CEC median). PTC/STC ratio: 89.7% (rank #19,653).

NEC 690.7 Limit

14 Panels Max @ -10 C (600 V)

Cold Voc reaches 41.7 V at -10 C (583.8 V string) and 42.93 V at -20 C (13 max).

8 kW Reference Array

35 Panels = 8,225 W STC

Occupies 57.3 m2 (617 sq ft) producing 7,374 W PTC; NEC 690.8 OCPD floor is 13.09 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 37.38 * (1 + (-0.33/100) * (-10 - 25)) = 41.7 V | OCPD = 1.56 * 8.39 = 13.09 A

Inputs from CEC Modules.csv for ZNSHINE PV-TECH Co Ltd ZXP6-60-235/P: Voc=37.38 V, beta_Voc=-0.33%/C, Isc=8.39 A, STC=235.0 W, Area=1.637 m2.

Result: 14 panels max on 600 V (583.8 V); 35 panels for 8 kW (617 sq ft).

What Are the Published CEC Specifications for ZNSHINE PV-TECH Co Ltd ZXP6-60-235/P?

Official CEC datasheet figures for ZNSHINE PV-TECH Co Ltd ZXP6-60-235/P (Mono-c-Si) used in utility interconnection and permit reviews.

Official California Energy Commission (NREL SAM) test parameters for ZNSHINE PV-TECH Co Ltd ZXP6-60-235/P.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 235.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 210.7 W (89.7% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 37.38 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.39 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 29.55 V / 7.95 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.33 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 14.36% (1.637 m2) Array roof footprint density
Cell Count & Technology 60 cells (Mono-c-Si) Monofacial backsheet

How Many ZNSHINE PV-TECH Co Ltd ZXP6-60-235/P Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many ZNSHINE PV-TECH Co Ltd ZXP6-60-235/P modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 26 6.11 kW 458 sq ft $1,529 $2,586
8 kW Class 35 8.22 kW 617 sq ft $2,057 $3,479
10 kW Class 43 10.11 kW 758 sq ft $2,530 $4,279

Which Sibling Wattage & Trim Variants Belong to This ZNSHINE PV-TECH Co Ltd Series?

Consolidated ZNSHINE PV-TECH Co Ltd wattage variants sharing the ZNSHINE PV-TECH Co Ltd ZXP6-60-235/P mechanical and cell layout.

Sibling CEC listings grouped into the ZNSHINE PV-TECH Co Ltd ZXP6-60-235/P wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
ZNSHINE PV-TECH Co Ltd ZXP6-60-225/P 225.0 W 201.5 W 37.04 V 29.15 V 13.75%
ZNSHINE PV-TECH Co Ltd ZXP6-60-230/P 230.0 W 206.1 W 37.21 V 29.35 V 14.05%
ZNSHINE PV-TECH Co Ltd ZXP6-60-235/P 235.0 W 210.7 W 37.38 V 29.55 V 14.36%
ZNSHINE PV-TECH Co Ltd ZXP6-60-240/P 240.0 W 215.3 W 37.55 V 29.75 V 14.66%
ZNSHINE PV-TECH Co Ltd ZXP6-60-245/P 245.0 W 219.9 W 37.72 V 29.95 V 14.97%

How Many ZNSHINE PV-TECH Co Ltd ZXP6-60-235/P Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on ZNSHINE PV-TECH Co Ltd ZXP6-60-235/P (41.7 V at 14 F).

Computed from Voc=37.38V and beta_Voc=-0.33%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 42.93 V 13 panels 558.1 V 23 panels
-10 C (14 F) 41.7 V 14 panels 583.8 V 23 panels
0 C (32 F) 40.46 V 14 panels 566.4 V 24 panels
25 C (77 F STC) 37.38 V 16 panels 598.1 V 26 panels

Which Cross-Brand Solar Modules Compare Closest to ZNSHINE PV-TECH Co Ltd ZXP6-60-235/P?

Competing CEC solar panels closest to ZNSHINE PV-TECH Co Ltd ZXP6-60-235/P in nameplate wattage and Voc, starting with APOS Energy AS235.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
APOS Energy AS235
APOS Energy
235.0 W Tie (0 W) 37.34 V 14.17% 89.7%
Gintech Energy GTE 235M
Gintech Energy
235.0 W Tie (0 W) 37.32 V 13.97% 89.5%
Advance Power API-M235
Advance Power
235.0 W Tie (0 W) 37.5 V 14.35% 89.3%
Auxin Solar AXN6M610T235
Auxin Solar
235.0 W Tie (0 W) 37.5 V 14.35% 89.3%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for ZNSHINE PV-TECH Co Ltd ZXP6-60-235/P?

Evaluate ZNSHINE PV-TECH Co Ltd ZXP6-60-235/P (235.0 W STC, 37.38 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), ZNSHINE PV-TECH Co Ltd ZXP6-60-235/P reaches 42.93 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 35 panels for an 8 kW build require 617 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 35 panels (617 sq ft).
  • 2026 tax credit baseline: cash residential installs of ZNSHINE PV-TECH Co Ltd ZXP6-60-235/P carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

ZNSHINE PV-TECH Co Ltd ZXP6-60-235/P 8 kW Residential Fit

Needs 35 modules (617 sq ft) with a 15 A string OCPD, offsetting ~$2,057/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 13 panels (-20 C), or compare APOS Energy AS235.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 210.7 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for ZNSHINE PV-TECH Co Ltd ZXP6-60-235/P by ZNSHINE PV-TECH Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for ZNSHINE PV-TECH Co Ltd ZXP6-60-235/P?

Multiplying ZNSHINE PV-TECH Co Ltd ZXP6-60-235/P's 8.39 A short-circuit current by 1.56 equals 13.09 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

Can ZNSHINE PV-TECH Co Ltd ZXP6-60-235/P pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 41.7 V cold Voc at 14 F and handles 8.39 A Isc; string inverters cap ZNSHINE PV-TECH Co Ltd ZXP6-60-235/P at 14 panels on 600 V.

Is ZNSHINE PV-TECH Co Ltd ZXP6-60-235/P eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of ZNSHINE PV-TECH Co Ltd ZXP6-60-235/P rely on utility bill offset (~$2,057/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.