Skip to main content
WireAndSun
Calculators
CEC PV Module

ZNSHINE PV-TECH Co Ltd ZXM6-D60-255/M — CEC Solar Module Specifications

Manufacturer: ZNSHINE PV-TECH Co Ltd Registry: CEC Verified Engineering Specification

ZNSHINE PV-TECH Co Ltd ZXM6-D60-255/M is a 255.0 W STC (229.1 W PTC) Mono-c-Si solar module ranking #19,421 of 21,677 CEC listings (below all-CEC median; higher than 9.2% of peers). It delivers 15.66% efficiency, 37.83 V Voc at 25 C, and 42.28 V cold Voc at -10 C (14 panels max per 600 V string).

STC Wattage
255.0 W
PTC Wattage
229.1 W
Voc @ 25C
37.83 V
Efficiency
15.66%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does ZNSHINE PV-TECH Co Ltd ZXM6-D60-255/M Compare Against Peer CEC Listings?

Solar engineering breakdown for ZNSHINE PV-TECH Co Ltd ZXM6-D60-255/M: PTC thermal retention, roof footprint, and cold Voc string bounds.

Across 5,889 Mono-c-Si listings from ZNSHINE PV-TECH Co Ltd and peers, ZNSHINE PV-TECH Co Ltd ZXM6-D60-255/M stands 155.0 W below the 410.0 W Mono-c-Si median and typical 89.8% PTC-to-STC thermal output (229.1 W real-world rating). Sizing 6 kW (24 panels) to 10 kW (40 panels) yields $1,532-$2,553/yr in baseline US bill offset. Lower 37.83 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters.

Where Does ZNSHINE PV-TECH Co Ltd ZXM6-D60-255/M Fall Across Listed CEC Models?

Distribution marker showing ZNSHINE PV-TECH Co Ltd ZXM6-D60-255/M (255.0 W) relative to the 385.0 W all-CEC solar panel median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where ZNSHINE PV-TECH Co Ltd ZXM6-D60-255/M (255.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCZNSHINE PV-TECH Co: 255.0 W

What Dataset Percentiles Define ZNSHINE PV-TECH Co Ltd ZXM6-D60-255/M?

Dataset percentiles tracking ZNSHINE PV-TECH Co Ltd ZXM6-D60-255/M power output, thermal retention ratio, and aperture efficiency against 21,677 models.

ZNSHINE PV-TECH Co Ltd ZXM6-D60-255/M Engineering BenchmarksPercentile comparison of ZNSHINE PV-TECH Co Ltd ZXM6-D60-255/M wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage255.0 WPTC/STC Retention89.8%Module Efficiency15.66%

What Do the Dataset Ranks Show for ZNSHINE PV-TECH Co Ltd ZXM6-D60-255/M?

Benchmark highlights for ZNSHINE PV-TECH Co Ltd ZXM6-D60-255/M covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #19,421 / 21,677

255.0 W STC · Higher Than 9.2%

255.0 W STC (-130.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #18,715

15.66% Aperture Efficiency

Power density 156.5 W/m2 (4.25 percentage points below 19.91% CEC median). PTC/STC ratio: 89.8% (rank #19,481).

NEC 690.7 Limit

14 Panels Max @ -10 C (600 V)

Cold Voc reaches 42.28 V at -10 C (591.9 V string) and 43.55 V at -20 C (13 max).

8 kW Reference Array

32 Panels = 8,160 W STC

Occupies 52.1 m2 (561 sq ft) producing 7,331 W PTC; NEC 690.8 OCPD floor is 13.85 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 37.83 * (1 + (-0.336/100) * (-10 - 25)) = 42.28 V | OCPD = 1.56 * 8.88 = 13.85 A

Inputs from CEC Modules.csv for ZNSHINE PV-TECH Co Ltd ZXM6-D60-255/M: Voc=37.83 V, beta_Voc=-0.336%/C, Isc=8.88 A, STC=255.0 W, Area=1.629 m2.

Result: 14 panels max on 600 V (591.9 V); 32 panels for 8 kW (561 sq ft).

What Are the Published CEC Specifications for ZNSHINE PV-TECH Co Ltd ZXM6-D60-255/M?

Official CEC datasheet figures for ZNSHINE PV-TECH Co Ltd ZXM6-D60-255/M (Mono-c-Si) used in utility interconnection and permit reviews.

Official California Energy Commission (NREL SAM) test parameters for ZNSHINE PV-TECH Co Ltd ZXM6-D60-255/M.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 255.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 229.1 W (89.8% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 37.83 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.88 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 30.62 V / 8.33 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.336 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 15.66% (1.629 m2) Array roof footprint density
Cell Count & Technology 60 cells (Mono-c-Si) Monofacial backsheet

How Many ZNSHINE PV-TECH Co Ltd ZXM6-D60-255/M Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many ZNSHINE PV-TECH Co Ltd ZXM6-D60-255/M modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 24 6.12 kW 421 sq ft $1,532 $2,590
8 kW Class 32 8.16 kW 561 sq ft $2,042 $3,454
10 kW Class 40 10.2 kW 701 sq ft $2,553 $4,317

Which Sibling Wattage & Trim Variants Belong to This ZNSHINE PV-TECH Co Ltd Series?

Consolidated ZNSHINE PV-TECH Co Ltd wattage variants sharing the ZNSHINE PV-TECH Co Ltd ZXM6-D60-255/M mechanical and cell layout.

Sibling CEC listings grouped into the ZNSHINE PV-TECH Co Ltd ZXM6-D60-255/M wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
ZNSHINE PV-TECH Co Ltd ZXM6-D60-250/M 250.0 W 224.5 W 37.72 V 30.49 V 15.35%
ZNSHINE PV-TECH Co Ltd ZXM6-D60-255/M 255.0 W 229.1 W 37.83 V 30.62 V 15.66%
ZNSHINE PV-TECH Co Ltd ZXM6-D60-260/M 260.0 W 233.7 W 37.91 V 30.7 V 15.96%

How Many ZNSHINE PV-TECH Co Ltd ZXM6-D60-255/M Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on ZNSHINE PV-TECH Co Ltd ZXM6-D60-255/M (42.28 V at 14 F).

Computed from Voc=37.83V and beta_Voc=-0.336%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 43.55 V 13 panels 566.1 V 22 panels
-10 C (14 F) 42.28 V 14 panels 591.9 V 23 panels
0 C (32 F) 41.01 V 14 panels 574.1 V 24 panels
25 C (77 F STC) 37.83 V 15 panels 567.4 V 26 panels

Which Cross-Brand Solar Modules Compare Closest to ZNSHINE PV-TECH Co Ltd ZXM6-D60-255/M?

Competing CEC solar panels closest to ZNSHINE PV-TECH Co Ltd ZXM6-D60-255/M in nameplate wattage and Voc, starting with GCL System Integration Technology Co Ltd GCL-P6/60255.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
GCL System Integration Technology Co Ltd GCL-P6/60255
GCL System Integration Technology Co Ltd
255.0 W Tie (0 W) 37.7 V 15.67% 90.4%
Advance Power API-M255
Advance Power
255.0 W Tie (0 W) 37.68 V 15.57% 89.5%
Eoplly New Energy Technology EP156P/60-255S AC
Eoplly New Energy Technology
255.0 W Tie (0 W) 37.68 V 15.6% 89.9%
Eoplly New Energy Technology EP156M/60-255 AC
Eoplly New Energy Technology
255.0 W Tie (0 W) 37.56 V 15.76% 89.9%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for ZNSHINE PV-TECH Co Ltd ZXM6-D60-255/M?

Evaluate ZNSHINE PV-TECH Co Ltd ZXM6-D60-255/M (255.0 W STC, 37.83 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), ZNSHINE PV-TECH Co Ltd ZXM6-D60-255/M reaches 43.55 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 32 panels for an 8 kW build require 561 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 32 panels (561 sq ft).
  • 2026 tax credit baseline: cash residential installs of ZNSHINE PV-TECH Co Ltd ZXM6-D60-255/M carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

ZNSHINE PV-TECH Co Ltd ZXM6-D60-255/M 8 kW Residential Fit

Needs 32 modules (561 sq ft) with a 15 A string OCPD, offsetting ~$2,042/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 13 panels (-20 C), or compare GCL System Integration Technology Co Ltd GCL-P6/60255.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 229.1 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for ZNSHINE PV-TECH Co Ltd ZXM6-D60-255/M by ZNSHINE PV-TECH Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for ZNSHINE PV-TECH Co Ltd ZXM6-D60-255/M?

Multiplying ZNSHINE PV-TECH Co Ltd ZXM6-D60-255/M's 8.88 A short-circuit current by 1.56 equals 13.85 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

Can ZNSHINE PV-TECH Co Ltd ZXM6-D60-255/M pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 42.28 V cold Voc at 14 F and handles 8.88 A Isc; string inverters cap ZNSHINE PV-TECH Co Ltd ZXM6-D60-255/M at 14 panels on 600 V.

Is ZNSHINE PV-TECH Co Ltd ZXM6-D60-255/M eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of ZNSHINE PV-TECH Co Ltd ZXM6-D60-255/M rely on utility bill offset (~$2,042/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.