Manufacturer: ZNSHINE PV-TECH Co Ltd Registry: CEC Verified Engineering Specification

ZNSHINE PV-TECH Co Ltd ZXM6-72-270/M is a 270.0 W STC (236.7 W PTC) Mono-c-Si solar module ranking #18,572 of 21,677 CEC listings (below all-CEC median; higher than 12.9% of peers). It delivers 13.91% efficiency, 44.39 V Voc at 25 C, and 50.42 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
270.0 W
PTC Wattage
236.7 W
Voc @ 25C
44.39 V
Efficiency
13.91%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does ZNSHINE PV-TECH Co Ltd ZXM6-72-270/M Compare Against Peer CEC Listings?

Solar engineering breakdown for ZNSHINE PV-TECH Co Ltd ZXM6-72-270/M: PTC thermal retention, roof footprint, and cold Voc string bounds.

Measured at 270.0 W STC and 236.7 W PTC, ZNSHINE PV-TECH Co Ltd ZXM6-72-270/M sits -115.0 W vs all-CEC median (below all-CEC median; higher than 12.9% of peers) among 21,677 listed modules. Power density reaches 139.1 W/m2 (6.00 percentage points below 19.91% CEC median). Mid-range 44.39 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F, whereas 1,000 V commercial inverters handle up to 19 panels in series. Alternative peer AXITEC AC-270P/156-72S rates 270.0 W.

Where Does ZNSHINE PV-TECH Co Ltd ZXM6-72-270/M Fall Across Listed CEC Models?

Distribution marker showing ZNSHINE PV-TECH Co Ltd ZXM6-72-270/M (270.0 W) relative to the 385.0 W all-CEC solar panel median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where ZNSHINE PV-TECH Co Ltd ZXM6-72-270/M (270.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCZNSHINE PV-TECH Co: 270.0 W

What Dataset Percentiles Define ZNSHINE PV-TECH Co Ltd ZXM6-72-270/M?

Dataset percentiles tracking ZNSHINE PV-TECH Co Ltd ZXM6-72-270/M power output, thermal retention ratio, and aperture efficiency against 21,677 models.

ZNSHINE PV-TECH Co Ltd ZXM6-72-270/M Engineering BenchmarksPercentile comparison of ZNSHINE PV-TECH Co Ltd ZXM6-72-270/M wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage270.0 WPTC/STC Retention87.7%Module Efficiency13.91%

What Do the Dataset Ranks Show for ZNSHINE PV-TECH Co Ltd ZXM6-72-270/M?

Benchmark highlights for ZNSHINE PV-TECH Co Ltd ZXM6-72-270/M covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #18,572 / 21,677

270.0 W STC · Higher Than 12.9%

270.0 W STC (-115.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #20,965

13.91% Aperture Efficiency

Power density 139.1 W/m2 (6.00 percentage points below 19.91% CEC median). PTC/STC ratio: 87.7% (rank #21,496).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 50.42 V at -10 C (554.6 V string) and 52.14 V at -20 C (11 max).

8 kW Reference Array

30 Panels = 8,100 W STC

Occupies 58.2 m2 (627 sq ft) producing 7,101 W PTC; NEC 690.8 OCPD floor is 12.99 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 44.39 * (1 + (-0.388/100) * (-10 - 25)) = 50.42 V | OCPD = 1.56 * 8.33 = 12.99 A

Inputs from CEC Modules.csv for ZNSHINE PV-TECH Co Ltd ZXM6-72-270/M: Voc=44.39 V, beta_Voc=-0.388%/C, Isc=8.33 A, STC=270.0 W, Area=1.941 m2.

Result: 11 panels max on 600 V (554.6 V); 30 panels for 8 kW (627 sq ft).

What Are the Published CEC Specifications for ZNSHINE PV-TECH Co Ltd ZXM6-72-270/M?

Official CEC datasheet figures for ZNSHINE PV-TECH Co Ltd ZXM6-72-270/M (Mono-c-Si) used in utility interconnection and permit reviews.

Official California Energy Commission (NREL SAM) test parameters for ZNSHINE PV-TECH Co Ltd ZXM6-72-270/M.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 270.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 236.7 W (87.7% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 44.39 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.33 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 36.0 V / 7.5 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.388 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 13.91% (1.941 m2) Array roof footprint density
Cell Count & Technology 12 cells (Mono-c-Si) Monofacial backsheet

How Many ZNSHINE PV-TECH Co Ltd ZXM6-72-270/M Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many ZNSHINE PV-TECH Co Ltd ZXM6-72-270/M modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 23 6.21 kW 481 sq ft $1,554 $2,628
8 kW Class 30 8.1 kW 627 sq ft $2,027 $3,428
10 kW Class 38 10.26 kW 794 sq ft $2,568 $4,342

Which Sibling Wattage & Trim Variants Belong to This ZNSHINE PV-TECH Co Ltd Series?

Consolidated ZNSHINE PV-TECH Co Ltd wattage variants sharing the ZNSHINE PV-TECH Co Ltd ZXM6-72-270/M mechanical and cell layout.

Sibling CEC listings grouped into the ZNSHINE PV-TECH Co Ltd ZXM6-72-270/M wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
ZNSHINE PV-TECH Co Ltd ZXM6-72-265/M 265.0 W 232.2 W 44.14 V 35.8 V 13.65%
ZNSHINE PV-TECH Co Ltd ZXM6-72-270/M 270.0 W 236.7 W 44.39 V 36.0 V 13.91%

How Many ZNSHINE PV-TECH Co Ltd ZXM6-72-270/M Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on ZNSHINE PV-TECH Co Ltd ZXM6-72-270/M (50.42 V at 14 F).

Computed from Voc=44.39V and beta_Voc=-0.388%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 52.14 V 11 panels 573.5 V 19 panels
-10 C (14 F) 50.42 V 11 panels 554.6 V 19 panels
0 C (32 F) 48.7 V 12 panels 584.4 V 20 panels
25 C (77 F STC) 44.39 V 13 panels 577.1 V 22 panels

Which Cross-Brand Solar Modules Compare Closest to ZNSHINE PV-TECH Co Ltd ZXM6-72-270/M?

Competing CEC solar panels closest to ZNSHINE PV-TECH Co Ltd ZXM6-72-270/M in nameplate wattage and Voc, starting with AXITEC AC-270P/156-72S.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
AXITEC AC-270P/156-72S
AXITEC
270.0 W Tie (0 W) 44.18 V 13.94% 89.9%
Advance Power API-M270
Advance Power
270.0 W Tie (0 W) 44.64 V 13.84% 89.0%
Auxin Solar AXN6M612T270
Auxin Solar
270.0 W Tie (0 W) 44.64 V 13.84% 89.0%
Centrosolar America DP72 270
Centrosolar America
270.0 W Tie (0 W) 43.85 V 13.89% 88.4%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for ZNSHINE PV-TECH Co Ltd ZXM6-72-270/M?

Evaluate ZNSHINE PV-TECH Co Ltd ZXM6-72-270/M (270.0 W STC, 44.39 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), ZNSHINE PV-TECH Co Ltd ZXM6-72-270/M reaches 52.14 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 30 panels for an 8 kW build require 627 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 30 panels (627 sq ft).
  • 2026 tax credit baseline: cash residential installs of ZNSHINE PV-TECH Co Ltd ZXM6-72-270/M carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

ZNSHINE PV-TECH Co Ltd ZXM6-72-270/M 8 kW Residential Fit

Needs 30 modules (627 sq ft) with a 15 A string OCPD, offsetting ~$2,027/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare AXITEC AC-270P/156-72S.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 236.7 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for ZNSHINE PV-TECH Co Ltd ZXM6-72-270/M by ZNSHINE PV-TECH Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.

How many ZNSHINE PV-TECH Co Ltd ZXM6-72-270/M panels fit on a 600 V winter solar string?

At -10 C (14 F), ZNSHINE PV-TECH Co Ltd ZXM6-72-270/M cold Voc rises from 44.39 V to 50.42 V (beta_Voc -0.388%/C), capping a 600 V string at 11 panels (554.6 V).

How much roof area does an 8 kW array of ZNSHINE PV-TECH Co Ltd ZXM6-72-270/M need?

An 8 kW DC system uses 30 ZNSHINE PV-TECH Co Ltd ZXM6-72-270/M modules (8,100 W STC / 7,101 W PTC), covering roughly 627 sq ft and saving ~$2,027/yr at 18.54 c/kWh.

How does ZNSHINE PV-TECH Co Ltd ZXM6-72-270/M compare against AXITEC AC-270P/156-72S?

ZNSHINE PV-TECH Co Ltd ZXM6-72-270/M outputs 270.0 W STC (44.39 V Voc, rank #18,572 of 21,677), while AXITEC AC-270P/156-72S delivers 270.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.