WAAREE ENERGIES LIMITED WSMD-520 is a 520.0 W STC (484.8 W PTC) Mono-c-Si solar module ranking #4,199 of 21,677 CEC listings (top 19.9%; higher than 80.1% of peers). It delivers 20.39% efficiency, 49.01 V Voc at 25 C, and 53.57 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 520.0 W
- PTC Wattage
- 484.8 W
- Voc @ 25C
- 49.01 V
- Efficiency
- 20.39%
How Does WAAREE ENERGIES LIMITED WSMD-520 Compare Against Peer CEC Listings?
How WAAREE ENERGIES LIMITED WAAREE ENERGIES LIMITED WSMD-520 handles rooftop heat (484.8 W PTC), 8 kW sizing, and cold winter string voltage.
For NEC string engineering, WAAREE ENERGIES LIMITED WSMD-520 exhibits 13.55 A short-circuit current, requiring a 21.14 A (156%) conductor rating and 25 A OCPD under NEC 690.8. Ranked #4,199 of 21,677 (110.0 W above the 410.0 W Mono-c-Si median), this modern high-density residential and light-commercial module covers 40.8 m2 for an 8 kW system (20 panels for 10 kW). Higher 49.01 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C).
Where Does WAAREE ENERGIES LIMITED WSMD-520 Fall Across Listed CEC Models?
Where WAAREE ENERGIES LIMITED WSMD-520 (520.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define WAAREE ENERGIES LIMITED WSMD-520?
Percentile placement of WAAREE ENERGIES LIMITED WSMD-520 across power density (203.9 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for WAAREE ENERGIES LIMITED WSMD-520?
Four critical engineering numbers homeowners and solar installers check first when reviewing WAAREE ENERGIES LIMITED WSMD-520 specifications. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.
Top 19.9% STC Output
520.0 W STC (+135.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
20.39% Aperture Efficiency
Power density 203.9 W/m2 (0.48 percentage points above 19.91% CEC median). PTC/STC ratio: 93.2% (rank #8,924).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 53.57 V at -10 C (589.3 V string) and 54.88 V at -20 C (10 max).
16 Panels = 8,320 W STC
Occupies 40.8 m2 (439 sq ft) producing 7,757 W PTC; NEC 690.8 OCPD floor is 21.14 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 49.01 * (1 + (-0.266/100) * (-10 - 25)) = 53.57 V | OCPD = 1.56 * 13.55 = 21.14 A
Inputs from CEC Modules.csv for WAAREE ENERGIES LIMITED WSMD-520: Voc=49.01 V, beta_Voc=-0.266%/C, Isc=13.55 A, STC=520.0 W, Area=2.55 m2.
Result: 11 panels max on 600 V (589.3 V); 16 panels for 8 kW (439 sq ft).
What Are the Published CEC Specifications for WAAREE ENERGIES LIMITED WSMD-520?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for WAAREE ENERGIES LIMITED WSMD-520.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 520.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 484.8 W (93.2% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 49.01 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 13.55 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 41.14 V / 12.65 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.266 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 20.39% (2.55 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Monofacial backsheet |
How Many WAAREE ENERGIES LIMITED WSMD-520 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using WAAREE ENERGIES LIMITED WSMD-520 (520.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 12 | 6.24 kW | 329 sq ft | $1,562 | $2,641 |
| 8 kW Class | 16 | 8.32 kW | 439 sq ft | $2,082 | $3,521 |
| 10 kW Class | 20 | 10.4 kW | 549 sq ft | $2,603 | $4,402 |
How Many WAAREE ENERGIES LIMITED WSMD-520 Modules Fit in a Cold-Weather String?
Maximum series module counts for WAAREE ENERGIES LIMITED WSMD-520 from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 54.88 V | 10 panels | 548.8 V | 18 panels |
| -10 C (14 F) | 53.57 V | 11 panels | 589.3 V | 18 panels |
| 0 C (32 F) | 52.27 V | 11 panels | 575.0 V | 19 panels |
| 25 C (77 F STC) | 49.01 V | 12 panels | 588.1 V | 20 panels |
Which Cross-Brand Solar Modules Compare Closest to WAAREE ENERGIES LIMITED WSMD-520?
Alternative CEC solar modules from competing brands near WAAREE ENERGIES LIMITED WSMD-520 (520.0 W), including AXITEC AC-520MH/144VB.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| AXITEC AC-520MH/144VB AXITEC |
520.0 W | Tie (0 W) | 49.0 V | 20.31% | 93.7% |
| ELITE Solar ET-M772BH520BB ELITE Solar |
520.0 W | Tie (0 W) | 49.0 V | 20.31% | 93.7% |
| Chint New Energy Technology Co Ltd CHSM72M-HC-520 Chint New Energy Technology Co Ltd |
520.0 W | Tie (0 W) | 48.9 V | 20.97% | 92.5% |
| IMPERIAL STAR SOLAR(CAMBODIA) CO LTD ISM7-SHDB144-520/M IMPERIAL STAR SOLAR(CAMBODIA) CO LTD |
520.0 W | Tie (0 W) | 48.88 V | 20.31% | 93.9% |
What Are the Design Limits and Best-Fit Uses for WAAREE ENERGIES LIMITED WSMD-520?
Evaluate WAAREE ENERGIES LIMITED WSMD-520 (520.0 W STC, 49.01 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), WAAREE ENERGIES LIMITED WSMD-520 reaches 54.88 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 16 panels for an 8 kW build require 439 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 16 panels (439 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of WAAREE ENERGIES LIMITED WSMD-520 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
WAAREE ENERGIES LIMITED WSMD-520 8 kW Residential Fit
Needs 16 modules (439 sq ft) with a 25 A string OCPD, offsetting ~$2,082/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare AXITEC AC-520MH/144VB.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 484.8 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for WAAREE ENERGIES LIMITED WSMD-520 by WAAREE ENERGIES LIMITED grounded in CEC test data and NEC 690.7/690.8 limits.
Why is WAAREE ENERGIES LIMITED WSMD-520 PTC wattage (484.8 W) lower than STC (520.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 484.8 W PTC (93.2% retention) across WAAREE ENERGIES LIMITED WSMD-520's 2.55 m2 aperture.
Who should skip WAAREE ENERGIES LIMITED WSMD-520 on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 16 WAAREE ENERGIES LIMITED WSMD-520 panels (439 sq ft) leave unusable roof gaps vs. AXITEC AC-520MH/144VB.
What is the 1,000 V commercial string limit for WAAREE ENERGIES LIMITED WSMD-520?
On 1,000 V commercial inverters at -10 C (53.57 V cold Voc), WAAREE ENERGIES LIMITED WSMD-520 fits up to 18 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting WAAREE ENERGIES LIMITED WSMD-520.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)