Skip to main content
WireAndSun
Calculators
CEC PV Module

WAAREE ENERGIES LIMITED WSMD-390 — CEC Solar Module Specifications

Manufacturer: WAAREE ENERGIES LIMITED Registry: CEC Verified Engineering Specification

WAAREE ENERGIES LIMITED WSMD-390 is a 390.0 W STC (363.1 W PTC) Mono-c-Si solar module ranking #10,321 of 21,677 CEC listings (top 49.5%; higher than 50.5% of peers). It delivers 19.5% efficiency, 48.76 V Voc at 25 C, and 52.79 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
390.0 W
PTC Wattage
363.1 W
Voc @ 25C
48.76 V
Efficiency
19.5%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does WAAREE ENERGIES LIMITED WSMD-390 Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for WAAREE ENERGIES LIMITED WSMD-390 (Mono-c-Si) residential solar systems.

Homeowners evaluating WAAREE ENERGIES LIMITED WSMD-390 need 16 panels for 6 kW or 21 panels (452 sq ft) for an 8 kW array—well-proportioned for residential pitched roofs needing 21 panels (452 sq ft) for an 8 kW array. Under NEC 690.7(A), beta_Voc (-0.236%/C) pushes open-circuit voltage to 52.79 V at 14 F and 53.94 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

Where Does WAAREE ENERGIES LIMITED WSMD-390 Fall Across Listed CEC Models?

Comparison of WAAREE ENERGIES LIMITED WSMD-390 (390.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where WAAREE ENERGIES LIMITED WSMD-390 (390.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCWAAREE ENERGIES LI: 390.0 W

What Dataset Percentiles Define WAAREE ENERGIES LIMITED WSMD-390?

Relative ranking of WAAREE ENERGIES LIMITED WSMD-390 across nameplate watts, 93.1% PTC thermal ratio, and module aperture efficiency.

WAAREE ENERGIES LIMITED WSMD-390 Engineering BenchmarksPercentile comparison of WAAREE ENERGIES LIMITED WSMD-390 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage390.0 WPTC/STC Retention93.1%Module Efficiency19.5%

What Do the Dataset Ranks Show for WAAREE ENERGIES LIMITED WSMD-390?

Summary of WAAREE ENERGIES LIMITED WSMD-390 output rank, 8 kW array size (21 panels), efficiency rating, and 600 V string limit.

Rank #10,321 / 21,677

Top 49.5% STC Output

390.0 W STC (+5.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #12,199

19.5% Aperture Efficiency

Power density 195.0 W/m2 (0.41 percentage points below 19.91% CEC median). PTC/STC ratio: 93.1% (rank #9,420).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 52.79 V at -10 C (580.7 V string) and 53.94 V at -20 C (11 max).

8 kW Reference Array

21 Panels = 8,190 W STC

Occupies 42.0 m2 (452 sq ft) producing 7,625 W PTC; NEC 690.8 OCPD floor is 16.05 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 48.76 * (1 + (-0.236/100) * (-10 - 25)) = 52.79 V | OCPD = 1.56 * 10.29 = 16.05 A

Inputs from CEC Modules.csv for WAAREE ENERGIES LIMITED WSMD-390: Voc=48.76 V, beta_Voc=-0.236%/C, Isc=10.29 A, STC=390.0 W, Area=2.0 m2.

Result: 11 panels max on 600 V (580.7 V); 21 panels for 8 kW (452 sq ft).

What Are the Published CEC Specifications for WAAREE ENERGIES LIMITED WSMD-390?

Complete CEC test sheet for WAAREE ENERGIES LIMITED WSMD-390 including Isc (10.29 A), Voc (48.76 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for WAAREE ENERGIES LIMITED WSMD-390.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 390.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 363.1 W (93.1% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 48.76 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 10.29 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 39.56 V / 9.87 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.236 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 19.5% (2.0 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Monofacial backsheet

How Many WAAREE ENERGIES LIMITED WSMD-390 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using WAAREE ENERGIES LIMITED WSMD-390.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 16 6.24 kW 344 sq ft $1,562 $2,641
8 kW Class 21 8.19 kW 452 sq ft $2,050 $3,466
10 kW Class 26 10.14 kW 560 sq ft $2,538 $4,292

Which Sibling Wattage & Trim Variants Belong to This WAAREE ENERGIES LIMITED Series?

Related WAAREE ENERGIES LIMITED power steps and black/silver trims consolidated into this WAAREE ENERGIES LIMITED WSMD-390 series guide.

Sibling CEC listings grouped into the WAAREE ENERGIES LIMITED WSMD-390 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
WAAREE ENERGIES LIMITED WSMD-380 380.0 W 353.6 W 48.14 V 39.07 V 19.0%
WAAREE ENERGIES LIMITED WSMD-385 385.0 W 358.3 W 48.45 V 39.32 V 19.25%
WAAREE ENERGIES LIMITED WSMD-390 390.0 W 363.1 W 48.76 V 39.56 V 19.5%
WAAREE ENERGIES LIMITED WSMD-395 395.0 W 367.9 W 49.07 V 39.81 V 19.75%

How Many WAAREE ENERGIES LIMITED WSMD-390 Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for WAAREE ENERGIES LIMITED WSMD-390 (48.76 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=48.76V and beta_Voc=-0.236%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 53.94 V 11 panels 593.3 V 18 panels
-10 C (14 F) 52.79 V 11 panels 580.7 V 18 panels
0 C (32 F) 51.64 V 11 panels 568.0 V 19 panels
25 C (77 F STC) 48.76 V 12 panels 585.1 V 20 panels

Which Cross-Brand Solar Modules Compare Closest to WAAREE ENERGIES LIMITED WSMD-390?

Four comparable CEC modules such as CSI Solar Co Ltd CS3U-390MS (390.0 W) for side-by-side solar quote checks.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
CSI Solar Co Ltd CS3U-390MS
CSI Solar Co Ltd
390.0 W Tie (0 W) 48.2 V 20.31% 93.2%
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-BHC-395W
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd
395.0 W +5.0 W 48.7 V 20.26% 92.9%
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-HC-395W
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd
395.0 W +5.0 W 48.7 V 20.68% 92.5%
Dehui Solar Power (Vietnam) CoLtd DH-M872F 395W
Dehui Solar Power (Vietnam) CoLtd
395.0 W +5.0 W 48.7 V 20.26% 92.9%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for WAAREE ENERGIES LIMITED WSMD-390?

Evaluate WAAREE ENERGIES LIMITED WSMD-390 (390.0 W STC, 48.76 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), WAAREE ENERGIES LIMITED WSMD-390 reaches 53.94 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 21 panels for an 8 kW build require 452 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 21 panels (452 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of WAAREE ENERGIES LIMITED WSMD-390 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

WAAREE ENERGIES LIMITED WSMD-390 8 kW Residential Fit

Needs 21 modules (452 sq ft) with a 20 A string OCPD, offsetting ~$2,050/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare CSI Solar Co Ltd CS3U-390MS.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 363.1 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for WAAREE ENERGIES LIMITED WSMD-390 by WAAREE ENERGIES LIMITED grounded in CEC test data and NEC 690.7/690.8 limits.

Why is WAAREE ENERGIES LIMITED WSMD-390 PTC wattage (363.1 W) lower than STC (390.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 363.1 W PTC (93.1% retention) across WAAREE ENERGIES LIMITED WSMD-390's 2.0 m2 aperture.

Who should skip WAAREE ENERGIES LIMITED WSMD-390 on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 21 WAAREE ENERGIES LIMITED WSMD-390 panels (452 sq ft) leave unusable roof gaps vs. CSI Solar Co Ltd CS3U-390MS.

What is the 1,000 V commercial string limit for WAAREE ENERGIES LIMITED WSMD-390?

On 1,000 V commercial inverters at -10 C (52.79 V cold Voc), WAAREE ENERGIES LIMITED WSMD-390 fits up to 18 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting WAAREE ENERGIES LIMITED WSMD-390.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.