WAAREE ENERGIES LIMITED WS-260 is a 260.0 W STC (235.5 W PTC) Multi-c-Si solar module ranking #19,146 of 21,677 CEC listings (below all-CEC median; higher than 10.4% of peers). It delivers 16.05% efficiency, 37.8 V Voc at 25 C, and 42.68 V cold Voc at -10 C (14 panels max per 600 V string).
- STC Wattage
- 260.0 W
- PTC Wattage
- 235.5 W
- Voc @ 25C
- 37.8 V
- Efficiency
- 16.05%
How Does WAAREE ENERGIES LIMITED WS-260 Compare Against Peer CEC Listings?
How WAAREE ENERGIES LIMITED WAAREE ENERGIES LIMITED WS-260 handles rooftop heat (235.5 W PTC), 8 kW sizing, and cold winter string voltage.
For NEC string engineering, WAAREE ENERGIES LIMITED WS-260 exhibits 9.1 A short-circuit current, requiring a 14.2 A (156%) conductor rating and 15 A OCPD under NEC 690.8. Ranked #19,146 of 21,677 (18.8 W below the 278.8 W Multi-c-Si median), this compact residential or specialty off-grid module covers 50.2 m2 for an 8 kW system (39 panels for 10 kW). Lower 37.8 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters.
Where Does WAAREE ENERGIES LIMITED WS-260 Fall Across Listed CEC Models?
Where WAAREE ENERGIES LIMITED WS-260 (260.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define WAAREE ENERGIES LIMITED WS-260?
Percentile placement of WAAREE ENERGIES LIMITED WS-260 across power density (160.5 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for WAAREE ENERGIES LIMITED WS-260?
Four critical engineering numbers homeowners and solar installers check first when reviewing WAAREE ENERGIES LIMITED WS-260 specifications. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.
260.0 W STC · Higher Than 10.4%
260.0 W STC (-125.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.
16.05% Aperture Efficiency
Power density 160.5 W/m2 (3.86 percentage points below 19.91% CEC median). PTC/STC ratio: 90.6% (rank #17,534).
14 Panels Max @ -10 C (600 V)
Cold Voc reaches 42.68 V at -10 C (597.5 V string) and 44.08 V at -20 C (13 max).
31 Panels = 8,060 W STC
Occupies 50.2 m2 (541 sq ft) producing 7,300 W PTC; NEC 690.8 OCPD floor is 14.2 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 37.8 * (1 + (-0.369/100) * (-10 - 25)) = 42.68 V | OCPD = 1.56 * 9.1 = 14.2 A
Inputs from CEC Modules.csv for WAAREE ENERGIES LIMITED WS-260: Voc=37.8 V, beta_Voc=-0.369%/C, Isc=9.1 A, STC=260.0 W, Area=1.62 m2.
Result: 14 panels max on 600 V (597.5 V); 31 panels for 8 kW (541 sq ft).
What Are the Published CEC Specifications for WAAREE ENERGIES LIMITED WS-260?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for WAAREE ENERGIES LIMITED WS-260.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 260.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 235.5 W (90.6% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 37.8 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.1 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 31.35 V / 8.3 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.369 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 16.05% (1.62 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Multi-c-Si) | Monofacial backsheet |
How Many WAAREE ENERGIES LIMITED WS-260 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using WAAREE ENERGIES LIMITED WS-260 (260.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 24 | 6.24 kW | 419 sq ft | $1,562 | $2,641 |
| 8 kW Class | 31 | 8.06 kW | 541 sq ft | $2,017 | $3,411 |
| 10 kW Class | 39 | 10.14 kW | 680 sq ft | $2,538 | $4,292 |
Which Sibling Wattage & Trim Variants Belong to This WAAREE ENERGIES LIMITED Series?
All closely matched WAAREE ENERGIES LIMITED wattages and cosmetic trims sharing the WAAREE ENERGIES LIMITED WS-260 architecture. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| WAAREE ENERGIES LIMITED WS-250 | 250.0 W | 226.2 W | 37.1 V | 31.15 V | 15.43% |
| WAAREE ENERGIES LIMITED WS-255 | 255.0 W | 230.9 W | 37.5 V | 31.3 V | 15.74% |
| WAAREE ENERGIES LIMITED WS-260 | 260.0 W | 235.5 W | 37.8 V | 31.35 V | 16.05% |
| WAAREE ENERGIES LIMITED WS-265 | 265.0 W | 240.2 W | 37.9 V | 31.45 V | 16.36% |
| WAAREE ENERGIES LIMITED WS-270 | 270.0 W | 244.9 W | 38.0 V | 31.6 V | 16.67% |
How Many WAAREE ENERGIES LIMITED WS-260 Modules Fit in a Cold-Weather String?
Maximum series module counts for WAAREE ENERGIES LIMITED WS-260 from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 44.08 V | 13 panels | 573.0 V | 22 panels |
| -10 C (14 F) | 42.68 V | 14 panels | 597.5 V | 23 panels |
| 0 C (32 F) | 41.29 V | 14 panels | 578.1 V | 24 panels |
| 25 C (77 F STC) | 37.8 V | 15 panels | 567.0 V | 26 panels |
Which Cross-Brand Solar Modules Compare Closest to WAAREE ENERGIES LIMITED WS-260?
Alternative CEC solar modules from competing brands near WAAREE ENERGIES LIMITED WS-260 (260.0 W), including Auxin Solar AXN6M610T260.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Auxin Solar AXN6M610T260 Auxin Solar |
260.0 W | Tie (0 W) | 37.8 V | 15.87% | 89.6% |
| CSI Solar Co Ltd CS6P-260M CSI Solar Co Ltd |
260.0 W | Tie (0 W) | 37.8 V | 16.79% | 91.3% |
| CSI Solar Co Ltd CS6P-260MX CSI Solar Co Ltd |
260.0 W | Tie (0 W) | 37.8 V | 16.79% | 90.7% |
| Gintung Energy ASEC-260G6M6A Gintung Energy |
260.0 W | Tie (0 W) | 37.78 V | 16.14% | 88.1% |
What Are the Design Limits and Best-Fit Uses for WAAREE ENERGIES LIMITED WS-260?
Evaluate WAAREE ENERGIES LIMITED WS-260 (260.0 W STC, 37.8 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), WAAREE ENERGIES LIMITED WS-260 reaches 44.08 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 31 panels for an 8 kW build require 541 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 31 panels (541 sq ft).
- 2026 tax credit baseline: cash residential installs of WAAREE ENERGIES LIMITED WS-260 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
WAAREE ENERGIES LIMITED WS-260 8 kW Residential Fit
Needs 31 modules (541 sq ft) with a 15 A string OCPD, offsetting ~$2,017/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 14 panels (-10 C) or 13 panels (-20 C), or compare Auxin Solar AXN6M610T260.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 235.5 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for WAAREE ENERGIES LIMITED WS-260 by WAAREE ENERGIES LIMITED grounded in CEC test data and NEC 690.7/690.8 limits.
Why is WAAREE ENERGIES LIMITED WS-260 PTC wattage (235.5 W) lower than STC (260.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 235.5 W PTC (90.6% retention) across WAAREE ENERGIES LIMITED WS-260's 1.62 m2 aperture.
Who should skip WAAREE ENERGIES LIMITED WS-260 on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 31 WAAREE ENERGIES LIMITED WS-260 panels (541 sq ft) leave unusable roof gaps vs. Auxin Solar AXN6M610T260.
What is the 1,000 V commercial string limit for WAAREE ENERGIES LIMITED WS-260?
On 1,000 V commercial inverters at -10 C (42.68 V cold Voc), WAAREE ENERGIES LIMITED WS-260 fits up to 23 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting WAAREE ENERGIES LIMITED WS-260.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)