Skip to main content
WireAndSun
Calculators
CEC PV Module

WAAREE ENERGIES LIMITED WS-235 — CEC Solar Module Specifications

Manufacturer: WAAREE ENERGIES LIMITED Registry: CEC Verified Engineering Specification

WAAREE ENERGIES LIMITED WS-235 is a 235.0 W STC (205.5 W PTC) Multi-c-Si solar module ranking #20,368 of 21,677 CEC listings (below all-CEC median; higher than 5.4% of peers). It delivers 14.3% efficiency, 36.0 V Voc at 25 C, and 40.52 V cold Voc at -10 C (14 panels max per 600 V string).

STC Wattage
235.0 W
PTC Wattage
205.5 W
Voc @ 25C
36.0 V
Efficiency
14.3%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does WAAREE ENERGIES LIMITED WS-235 Compare Against Peer CEC Listings?

Solar engineering breakdown for WAAREE ENERGIES LIMITED WS-235: PTC thermal retention, roof footprint, and cold Voc string bounds.

Across 1,407 Multi-c-Si listings from WAAREE ENERGIES LIMITED and peers, WAAREE ENERGIES LIMITED WS-235 stands 43.8 W below the 278.8 W Multi-c-Si median and typical 87.4% PTC-to-STC thermal output (205.5 W real-world rating). Sizing 6 kW (26 panels) to 10 kW (43 panels) yields $1,529-$2,530/yr in baseline US bill offset. Lower 36.0 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters.

Where Does WAAREE ENERGIES LIMITED WS-235 Fall Across Listed CEC Models?

Distribution marker showing WAAREE ENERGIES LIMITED WS-235 (235.0 W) relative to the 385.0 W all-CEC solar panel median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where WAAREE ENERGIES LIMITED WS-235 (235.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCWAAREE ENERGIES LI: 235.0 W

What Dataset Percentiles Define WAAREE ENERGIES LIMITED WS-235?

Dataset percentiles tracking WAAREE ENERGIES LIMITED WS-235 power output, thermal retention ratio, and aperture efficiency against 21,677 models.

WAAREE ENERGIES LIMITED WS-235 Engineering BenchmarksPercentile comparison of WAAREE ENERGIES LIMITED WS-235 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage235.0 WPTC/STC Retention87.4%Module Efficiency14.3%

What Do the Dataset Ranks Show for WAAREE ENERGIES LIMITED WS-235?

Benchmark highlights for WAAREE ENERGIES LIMITED WS-235 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #20,368 / 21,677

235.0 W STC · Higher Than 5.4%

235.0 W STC (-150.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #20,631

14.3% Aperture Efficiency

Power density 143.0 W/m2 (5.61 percentage points below 19.91% CEC median). PTC/STC ratio: 87.4% (rank #21,562).

NEC 690.7 Limit

14 Panels Max @ -10 C (600 V)

Cold Voc reaches 40.52 V at -10 C (567.3 V string) and 41.82 V at -20 C (14 max).

8 kW Reference Array

35 Panels = 8,225 W STC

Occupies 57.5 m2 (619 sq ft) producing 7,192 W PTC; NEC 690.8 OCPD floor is 13.57 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 36.0 * (1 + (-0.359/100) * (-10 - 25)) = 40.52 V | OCPD = 1.56 * 8.7 = 13.57 A

Inputs from CEC Modules.csv for WAAREE ENERGIES LIMITED WS-235: Voc=36.0 V, beta_Voc=-0.359%/C, Isc=8.7 A, STC=235.0 W, Area=1.643 m2.

Result: 14 panels max on 600 V (567.3 V); 35 panels for 8 kW (619 sq ft).

What Are the Published CEC Specifications for WAAREE ENERGIES LIMITED WS-235?

Official CEC datasheet figures for WAAREE ENERGIES LIMITED WS-235 (Multi-c-Si) used in utility interconnection and permit reviews. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Official California Energy Commission (NREL SAM) test parameters for WAAREE ENERGIES LIMITED WS-235.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 235.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 205.5 W (87.4% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 36.0 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.7 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 29.0 V / 8.11 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.359 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 14.3% (1.643 m2) Array roof footprint density
Cell Count & Technology 60 cells (Multi-c-Si) Monofacial backsheet

How Many WAAREE ENERGIES LIMITED WS-235 Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many WAAREE ENERGIES LIMITED WS-235 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 26 6.11 kW 460 sq ft $1,529 $2,586
8 kW Class 35 8.22 kW 619 sq ft $2,057 $3,479
10 kW Class 43 10.11 kW 760 sq ft $2,530 $4,279

Which Sibling Wattage & Trim Variants Belong to This WAAREE ENERGIES LIMITED Series?

Consolidated WAAREE ENERGIES LIMITED wattage variants sharing the WAAREE ENERGIES LIMITED WS-235 mechanical and cell layout. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Sibling CEC listings grouped into the WAAREE ENERGIES LIMITED WS-235 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
WAAREE ENERGIES LIMITED WS-225 225.0 W 196.5 W 36.0 V 29.0 V 13.69%
WAAREE ENERGIES LIMITED WS-230 230.0 W 201.0 W 36.0 V 29.0 V 14.0%
WAAREE ENERGIES LIMITED WS-235 235.0 W 205.5 W 36.0 V 29.0 V 14.3%
WAAREE ENERGIES LIMITED WS-240 240.0 W 210.0 W 36.0 V 29.0 V 14.6%

How Many WAAREE ENERGIES LIMITED WS-235 Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on WAAREE ENERGIES LIMITED WS-235 (40.52 V at 14 F).

Computed from Voc=36.0V and beta_Voc=-0.359%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 41.82 V 14 panels 585.5 V 23 panels
-10 C (14 F) 40.52 V 14 panels 567.3 V 24 panels
0 C (32 F) 39.23 V 15 panels 588.4 V 25 panels
25 C (77 F STC) 36.0 V 16 panels 576.0 V 27 panels

Which Cross-Brand Solar Modules Compare Closest to WAAREE ENERGIES LIMITED WS-235?

Competing CEC solar panels closest to WAAREE ENERGIES LIMITED WS-235 in nameplate wattage and Voc, starting with Anhui Rinengzhongtian Semiconductor Development QJP235-60.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Anhui Rinengzhongtian Semiconductor Development QJP235-60
Anhui Rinengzhongtian Semiconductor Development
235.0 W Tie (0 W) 36.1 V 14.44% 89.3%
Changzhou Nesl Solartech DJ-235P-ST15
Changzhou Nesl Solartech
235.0 W Tie (0 W) 36.2 V 14.39% 90.3%
Anhui Rinengzhongtian Semiconductor Development QJM235-60
Anhui Rinengzhongtian Semiconductor Development
235.0 W Tie (0 W) 36.65 V 14.44% 90.0%
Advance Power API-P235
Advance Power
235.0 W Tie (0 W) 36.72 V 14.35% 89.2%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for WAAREE ENERGIES LIMITED WS-235?

Evaluate WAAREE ENERGIES LIMITED WS-235 (235.0 W STC, 36.0 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), WAAREE ENERGIES LIMITED WS-235 reaches 41.82 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 35 panels for an 8 kW build require 619 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 35 panels (619 sq ft).
  • 2026 tax credit baseline: cash residential installs of WAAREE ENERGIES LIMITED WS-235 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

WAAREE ENERGIES LIMITED WS-235 8 kW Residential Fit

Needs 35 modules (619 sq ft) with a 15 A string OCPD, offsetting ~$2,057/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare Anhui Rinengzhongtian Semiconductor Development QJP235-60.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 205.5 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for WAAREE ENERGIES LIMITED WS-235 by WAAREE ENERGIES LIMITED grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for WAAREE ENERGIES LIMITED WS-235?

Multiplying WAAREE ENERGIES LIMITED WS-235's 8.7 A short-circuit current by 1.56 equals 13.57 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

Can WAAREE ENERGIES LIMITED WS-235 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 40.52 V cold Voc at 14 F and handles 8.7 A Isc; string inverters cap WAAREE ENERGIES LIMITED WS-235 at 14 panels on 600 V.

Is WAAREE ENERGIES LIMITED WS-235 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of WAAREE ENERGIES LIMITED WS-235 rely on utility bill offset (~$2,057/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.