Skip to main content
WireAndSun
Calculators
CEC PV Module

WAAREE ENERGIES LIMITED BiN-07-535 — CEC Solar Module Specifications

Manufacturer: WAAREE ENERGIES LIMITED Registry: CEC Verified Engineering Specification

WAAREE ENERGIES LIMITED BiN-07-535 is a 535.0 W STC (507.2 W PTC) Mono-c-Si solar module ranking #3,537 of 21,677 CEC listings (top 17.5%; higher than 82.5% of peers). It delivers 22.86% efficiency, 48.18 V Voc at 25 C, and 52.23 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
535.0 W
PTC Wattage
507.2 W
Voc @ 25C
48.18 V
Efficiency
22.86%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does WAAREE ENERGIES LIMITED BiN-07-535 Compare Against Peer CEC Listings?

How WAAREE ENERGIES LIMITED WAAREE ENERGIES LIMITED BiN-07-535 handles rooftop heat (507.2 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, WAAREE ENERGIES LIMITED BiN-07-535 exhibits 13.97 A short-circuit current, requiring a 21.79 A (156%) conductor rating and 25 A OCPD under NEC 690.8. Ranked #3,537 of 21,677 (125.0 W above the 410.0 W Mono-c-Si median), this large-format commercial and ground-mount module covers 35.1 m2 for an 8 kW system (19 panels for 10 kW). Higher 48.18 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C).

Where Does WAAREE ENERGIES LIMITED BiN-07-535 Fall Across Listed CEC Models?

Where WAAREE ENERGIES LIMITED BiN-07-535 (535.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where WAAREE ENERGIES LIMITED BiN-07-535 (535.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCWAAREE ENERGIES LI: 535.0 W

What Dataset Percentiles Define WAAREE ENERGIES LIMITED BiN-07-535?

Percentile placement of WAAREE ENERGIES LIMITED BiN-07-535 across power density (228.6 W/m2), thermal retention, and nameplate STC wattage.

WAAREE ENERGIES LIMITED BiN-07-535 Engineering BenchmarksPercentile comparison of WAAREE ENERGIES LIMITED BiN-07-535 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage535.0 WPTC/STC Retention94.8%Module Efficiency22.86%

What Do the Dataset Ranks Show for WAAREE ENERGIES LIMITED BiN-07-535?

Four critical engineering numbers homeowners and solar installers check first when reviewing WAAREE ENERGIES LIMITED BiN-07-535 specifications. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

Rank #3,537 / 21,677

Top 17.5% STC Output

535.0 W STC (+150.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #1,396

22.86% Aperture Efficiency

Power density 228.6 W/m2 (2.95 percentage points above 19.91% CEC median). PTC/STC ratio: 94.8% (rank #1,790).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 52.23 V at -10 C (574.5 V string) and 53.38 V at -20 C (11 max).

8 kW Reference Array

15 Panels = 8,025 W STC

Occupies 35.1 m2 (378 sq ft) producing 7,608 W PTC; NEC 690.8 OCPD floor is 21.79 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 48.18 * (1 + (-0.24/100) * (-10 - 25)) = 52.23 V | OCPD = 1.56 * 13.97 = 21.79 A

Inputs from CEC Modules.csv for WAAREE ENERGIES LIMITED BiN-07-535: Voc=48.18 V, beta_Voc=-0.24%/C, Isc=13.97 A, STC=535.0 W, Area=2.34 m2.

Result: 11 panels max on 600 V (574.5 V); 15 panels for 8 kW (378 sq ft).

What Are the Published CEC Specifications for WAAREE ENERGIES LIMITED BiN-07-535?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for WAAREE ENERGIES LIMITED BiN-07-535.

Official California Energy Commission (NREL SAM) test parameters for WAAREE ENERGIES LIMITED BiN-07-535.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 535.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 507.2 W (94.8% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 48.18 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 13.97 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 40.47 V / 13.22 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.24 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 22.86% (2.34 m2) Array roof footprint density
Cell Count & Technology 66 cells (Mono-c-Si) Bifacial glass-glass

How Many WAAREE ENERGIES LIMITED BiN-07-535 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using WAAREE ENERGIES LIMITED BiN-07-535 (535.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 12 6.42 kW 302 sq ft $1,607 $2,717
8 kW Class 15 8.03 kW 378 sq ft $2,010 $3,398
10 kW Class 19 10.16 kW 479 sq ft $2,543 $4,300

Which Sibling Wattage & Trim Variants Belong to This WAAREE ENERGIES LIMITED Series?

All closely matched WAAREE ENERGIES LIMITED wattages and cosmetic trims sharing the WAAREE ENERGIES LIMITED BiN-07-535 architecture. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Sibling CEC listings grouped into the WAAREE ENERGIES LIMITED BiN-07-535 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
WAAREE ENERGIES LIMITED BiN-07-525 525.0 W 497.5 W 47.79 V 40.2 V 22.44%
WAAREE ENERGIES LIMITED BiN-07-530 530.0 W 502.4 W 47.99 V 40.33 V 22.65%
WAAREE ENERGIES LIMITED BiN-07-535 535.0 W 507.2 W 48.18 V 40.47 V 22.86%
WAAREE ENERGIES LIMITED BiN-07-540 540.0 W 512.1 W 48.38 V 40.6 V 23.08%
WAAREE ENERGIES LIMITED BiN-07-545 545.0 W 516.9 W 48.58 V 40.73 V 23.29%

How Many WAAREE ENERGIES LIMITED BiN-07-535 Modules Fit in a Cold-Weather String?

Maximum series module counts for WAAREE ENERGIES LIMITED BiN-07-535 from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=48.18V and beta_Voc=-0.24%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 53.38 V 11 panels 587.2 V 18 panels
-10 C (14 F) 52.23 V 11 panels 574.5 V 19 panels
0 C (32 F) 51.07 V 11 panels 561.8 V 19 panels
25 C (77 F STC) 48.18 V 12 panels 578.2 V 20 panels

Which Cross-Brand Solar Modules Compare Closest to WAAREE ENERGIES LIMITED BiN-07-535?

Alternative CEC solar modules from competing brands near WAAREE ENERGIES LIMITED BiN-07-535 (535.0 W), including AMPS Solar AMPS-535P-144SW.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
AMPS Solar AMPS-535P-144SW
AMPS Solar
535.0 W Tie (0 W) 48.67 V 20.9% 94.2%
CSI Solar Co Ltd CS6W-535MB
CSI Solar Co Ltd
535.0 W Tie (0 W) 49.0 V 21.15% 94.1%
CSI Solar Co Ltd CS6W-535MB-AG
CSI Solar Co Ltd
535.0 W Tie (0 W) 49.0 V 21.4% 94.1%
GOLDI SUN PRIVATE LIMITED GS10-B144-TF-535
GOLDI SUN PRIVATE LIMITED
535.0 W Tie (0 W) 49.39 V 20.74% 93.3%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for WAAREE ENERGIES LIMITED BiN-07-535?

Evaluate WAAREE ENERGIES LIMITED BiN-07-535 (535.0 W STC, 48.18 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), WAAREE ENERGIES LIMITED BiN-07-535 reaches 53.38 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 15 panels for an 8 kW build require 378 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
  • 2026 tax credit baseline: cash residential installs of WAAREE ENERGIES LIMITED BiN-07-535 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

WAAREE ENERGIES LIMITED BiN-07-535 8 kW Residential Fit

Needs 15 modules (378 sq ft) with a 25 A string OCPD, offsetting ~$2,010/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare AMPS Solar AMPS-535P-144SW.

Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 507.2 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for WAAREE ENERGIES LIMITED BiN-07-535 by WAAREE ENERGIES LIMITED grounded in CEC test data and NEC 690.7/690.8 limits.

Why is WAAREE ENERGIES LIMITED BiN-07-535 PTC wattage (507.2 W) lower than STC (535.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 507.2 W PTC (94.8% retention) across WAAREE ENERGIES LIMITED BiN-07-535's 2.34 m2 aperture.

Who should skip WAAREE ENERGIES LIMITED BiN-07-535 on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 15 WAAREE ENERGIES LIMITED BiN-07-535 panels (378 sq ft) leave unusable roof gaps vs. AMPS Solar AMPS-535P-144SW.

What is the 1,000 V commercial string limit for WAAREE ENERGIES LIMITED BiN-07-535?

On 1,000 V commercial inverters at -10 C (52.23 V cold Voc), WAAREE ENERGIES LIMITED BiN-07-535 fits up to 19 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting WAAREE ENERGIES LIMITED BiN-07-535.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.