Skip to main content
WireAndSun
Calculators
CEC PV Module

WAAREE ENERGIES LIMITED Bi-66-590 — CEC Solar Module Specifications

Manufacturer: WAAREE ENERGIES LIMITED Registry: CEC Verified Engineering Specification

WAAREE ENERGIES LIMITED Bi-66-590 is a 590.0 W STC (546.8 W PTC) Mono-c-Si solar module ranking #1,597 of 21,677 CEC listings (top 8.1%; higher than 91.9% of peers). It delivers 21.0% efficiency, 41.9 V Voc at 25 C, and 45.82 V cold Voc at -10 C (13 panels max per 600 V string).

STC Wattage
590.0 W
PTC Wattage
546.8 W
Voc @ 25C
41.9 V
Efficiency
21.0%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does WAAREE ENERGIES LIMITED Bi-66-590 Compare Against Peer CEC Listings?

How WAAREE ENERGIES LIMITED WAAREE ENERGIES LIMITED Bi-66-590 handles rooftop heat (546.8 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, WAAREE ENERGIES LIMITED Bi-66-590 exhibits 17.84 A short-circuit current, requiring a 27.83 A (156%) conductor rating and 30 A OCPD under NEC 690.8. Ranked #1,597 of 21,677 (180.0 W above the 410.0 W Mono-c-Si median), this large-format commercial and ground-mount module covers 39.3 m2 for an 8 kW system (17 panels for 10 kW). Mid-range 41.9 V open-circuit voltage allows up to 13 panels per 600 V string at 14 F.

Where Does WAAREE ENERGIES LIMITED Bi-66-590 Fall Across Listed CEC Models?

Where WAAREE ENERGIES LIMITED Bi-66-590 (590.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where WAAREE ENERGIES LIMITED Bi-66-590 (590.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCWAAREE ENERGIES LI: 590.0 W

What Dataset Percentiles Define WAAREE ENERGIES LIMITED Bi-66-590?

Percentile placement of WAAREE ENERGIES LIMITED Bi-66-590 across power density (210.0 W/m2), thermal retention, and nameplate STC wattage.

WAAREE ENERGIES LIMITED Bi-66-590 Engineering BenchmarksPercentile comparison of WAAREE ENERGIES LIMITED Bi-66-590 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage590.0 WPTC/STC Retention92.7%Module Efficiency21.0%

What Do the Dataset Ranks Show for WAAREE ENERGIES LIMITED Bi-66-590?

Four critical engineering numbers homeowners and solar installers check first when reviewing WAAREE ENERGIES LIMITED Bi-66-590 specifications. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Rank #1,597 / 21,677

Top 8.1% STC Output

590.0 W STC (+205.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #6,445

21.0% Aperture Efficiency

Power density 210.0 W/m2 (1.09 percentage points above 19.91% CEC median). PTC/STC ratio: 92.7% (rank #11,468).

NEC 690.7 Limit

13 Panels Max @ -10 C (600 V)

Cold Voc reaches 45.82 V at -10 C (595.7 V string) and 46.93 V at -20 C (12 max).

8 kW Reference Array

14 Panels = 8,260 W STC

Occupies 39.3 m2 (423 sq ft) producing 7,655 W PTC; NEC 690.8 OCPD floor is 27.83 A (30 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 41.9 * (1 + (-0.267/100) * (-10 - 25)) = 45.82 V | OCPD = 1.56 * 17.84 = 27.83 A

Inputs from CEC Modules.csv for WAAREE ENERGIES LIMITED Bi-66-590: Voc=41.9 V, beta_Voc=-0.267%/C, Isc=17.84 A, STC=590.0 W, Area=2.81 m2.

Result: 13 panels max on 600 V (595.7 V); 14 panels for 8 kW (423 sq ft).

What Are the Published CEC Specifications for WAAREE ENERGIES LIMITED Bi-66-590?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for WAAREE ENERGIES LIMITED Bi-66-590.

Official California Energy Commission (NREL SAM) test parameters for WAAREE ENERGIES LIMITED Bi-66-590.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 590.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 546.8 W (92.7% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 41.9 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 17.84 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 34.39 V / 17.16 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.267 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 21.0% (2.81 m2) Array roof footprint density
Cell Count & Technology 60 cells (Mono-c-Si) Bifacial glass-glass

How Many WAAREE ENERGIES LIMITED Bi-66-590 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using WAAREE ENERGIES LIMITED Bi-66-590 (590.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 11 6.49 kW 333 sq ft $1,624 $2,747
8 kW Class 14 8.26 kW 423 sq ft $2,067 $3,496
10 kW Class 17 10.03 kW 514 sq ft $2,510 $4,245

Which Sibling Wattage & Trim Variants Belong to This WAAREE ENERGIES LIMITED Series?

All closely matched WAAREE ENERGIES LIMITED wattages and cosmetic trims sharing the WAAREE ENERGIES LIMITED Bi-66-590 architecture. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Sibling CEC listings grouped into the WAAREE ENERGIES LIMITED Bi-66-590 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
WAAREE ENERGIES LIMITED Bi-66-580 580.0 W 537.2 W 41.56 V 34.21 V 20.64%
WAAREE ENERGIES LIMITED Bi-66-585 585.0 W 542.0 W 41.76 V 34.34 V 20.82%
WAAREE ENERGIES LIMITED Bi-66-590 590.0 W 546.8 W 41.9 V 34.39 V 21.0%
WAAREE ENERGIES LIMITED Bi-66-595 595.0 W 551.5 W 42.05 V 34.44 V 21.17%

How Many WAAREE ENERGIES LIMITED Bi-66-590 Modules Fit in a Cold-Weather String?

Maximum series module counts for WAAREE ENERGIES LIMITED Bi-66-590 from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=41.9V and beta_Voc=-0.267%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 46.93 V 12 panels 563.2 V 21 panels
-10 C (14 F) 45.82 V 13 panels 595.7 V 21 panels
0 C (32 F) 44.7 V 13 panels 581.1 V 22 panels
25 C (77 F STC) 41.9 V 14 panels 586.6 V 23 panels

Which Cross-Brand Solar Modules Compare Closest to WAAREE ENERGIES LIMITED Bi-66-590?

Alternative CEC solar modules from competing brands near WAAREE ENERGIES LIMITED Bi-66-590 (590.0 W), including CSI Solar Co Ltd CS7L-585MB-AG.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
CSI Solar Co Ltd CS7L-585MB-AG
CSI Solar Co Ltd
585.0 W -5.0 W 40.7 V 27.34% 93.9%
CSI Solar Co Ltd CS62-66TB-590H
CSI Solar Co Ltd
590.0 W Tie (0 W) 47.2 V 22.52% 95.0%
CSI Solar Co Ltd CS62-66TB-590HR
CSI Solar Co Ltd
590.0 W Tie (0 W) 48.5 V 22.52% 94.6%
CSI Solar Co Ltd CS62-66TB-595HP
CSI Solar Co Ltd
595.0 W +5.0 W 47.4 V 22.71% 95.0%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for WAAREE ENERGIES LIMITED Bi-66-590?

Evaluate WAAREE ENERGIES LIMITED Bi-66-590 (590.0 W STC, 41.9 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), WAAREE ENERGIES LIMITED Bi-66-590 reaches 46.93 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 14 panels for an 8 kW build require 423 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
  • 2026 tax credit baseline: cash residential installs of WAAREE ENERGIES LIMITED Bi-66-590 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

WAAREE ENERGIES LIMITED Bi-66-590 8 kW Residential Fit

Needs 14 modules (423 sq ft) with a 30 A string OCPD, offsetting ~$2,067/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 12 panels (-20 C), or compare CSI Solar Co Ltd CS7L-585MB-AG.

Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 546.8 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for WAAREE ENERGIES LIMITED Bi-66-590 by WAAREE ENERGIES LIMITED grounded in CEC test data and NEC 690.7/690.8 limits.

Why is WAAREE ENERGIES LIMITED Bi-66-590 PTC wattage (546.8 W) lower than STC (590.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 546.8 W PTC (92.7% retention) across WAAREE ENERGIES LIMITED Bi-66-590's 2.81 m2 aperture.

Who should skip WAAREE ENERGIES LIMITED Bi-66-590 on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 14 WAAREE ENERGIES LIMITED Bi-66-590 panels (423 sq ft) leave unusable roof gaps vs. CSI Solar Co Ltd CS7L-585MB-AG.

What is the 1,000 V commercial string limit for WAAREE ENERGIES LIMITED Bi-66-590?

On 1,000 V commercial inverters at -10 C (45.82 V cold Voc), WAAREE ENERGIES LIMITED Bi-66-590 fits up to 21 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting WAAREE ENERGIES LIMITED Bi-66-590.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.