WAAREE ENERGIES LIMITED Bi-33-435 is a 435.0 W STC (404.3 W PTC) Mono-c-Si solar module ranking #6,850 of 21,677 CEC listings (top 33.5%; higher than 66.5% of peers). It delivers 19.68% efficiency, 49.59 V Voc at 25 C, and 53.69 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 435.0 W
- PTC Wattage
- 404.3 W
- Voc @ 25C
- 49.59 V
- Efficiency
- 19.68%
How Does WAAREE ENERGIES LIMITED Bi-33-435 Compare Against Peer CEC Listings?
How WAAREE ENERGIES LIMITED WAAREE ENERGIES LIMITED Bi-33-435 handles rooftop heat (404.3 W PTC), 8 kW sizing, and cold winter string voltage.
For NEC string engineering, WAAREE ENERGIES LIMITED Bi-33-435 exhibits 11.25 A short-circuit current, requiring a 17.55 A (156%) conductor rating and 20 A OCPD under NEC 690.8. Ranked #6,850 of 21,677 (25.0 W above the 410.0 W Mono-c-Si median), this modern high-density residential and light-commercial module covers 42.0 m2 for an 8 kW system (23 panels for 10 kW). Higher 49.59 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C).
Where Does WAAREE ENERGIES LIMITED Bi-33-435 Fall Across Listed CEC Models?
Where WAAREE ENERGIES LIMITED Bi-33-435 (435.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define WAAREE ENERGIES LIMITED Bi-33-435?
Percentile placement of WAAREE ENERGIES LIMITED Bi-33-435 across power density (196.8 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for WAAREE ENERGIES LIMITED Bi-33-435?
Four critical engineering numbers homeowners and solar installers check first when reviewing WAAREE ENERGIES LIMITED Bi-33-435 specifications. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.
Top 33.5% STC Output
435.0 W STC (+50.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
19.68% Aperture Efficiency
Power density 196.8 W/m2 (0.23 percentage points below 19.91% CEC median). PTC/STC ratio: 92.9% (rank #10,348).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 53.69 V at -10 C (590.6 V string) and 54.86 V at -20 C (10 max).
19 Panels = 8,265 W STC
Occupies 42.0 m2 (452 sq ft) producing 7,682 W PTC; NEC 690.8 OCPD floor is 17.55 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 49.59 * (1 + (-0.236/100) * (-10 - 25)) = 53.69 V | OCPD = 1.56 * 11.25 = 17.55 A
Inputs from CEC Modules.csv for WAAREE ENERGIES LIMITED Bi-33-435: Voc=49.59 V, beta_Voc=-0.236%/C, Isc=11.25 A, STC=435.0 W, Area=2.21 m2.
Result: 11 panels max on 600 V (590.6 V); 19 panels for 8 kW (452 sq ft).
What Are the Published CEC Specifications for WAAREE ENERGIES LIMITED Bi-33-435?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for WAAREE ENERGIES LIMITED Bi-33-435.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 435.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 404.3 W (92.9% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 49.59 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 11.25 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 41.21 V / 10.56 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.236 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 19.68% (2.21 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Bifacial glass-glass |
How Many WAAREE ENERGIES LIMITED Bi-33-435 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using WAAREE ENERGIES LIMITED Bi-33-435 (435.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 14 | 6.09 kW | 333 sq ft | $1,524 | $2,577 |
| 8 kW Class | 19 | 8.27 kW | 452 sq ft | $2,070 | $3,500 |
| 10 kW Class | 23 | 10.01 kW | 547 sq ft | $2,505 | $4,236 |
Which Sibling Wattage & Trim Variants Belong to This WAAREE ENERGIES LIMITED Series?
All closely matched WAAREE ENERGIES LIMITED wattages and cosmetic trims sharing the WAAREE ENERGIES LIMITED Bi-33-435 architecture. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| WAAREE ENERGIES LIMITED Bi-33-425 | 425.0 W | 394.8 W | 49.19 V | 40.81 V | 19.23% |
| WAAREE ENERGIES LIMITED Bi-33-430 | 430.0 W | 399.5 W | 49.39 V | 41.01 V | 19.46% |
| WAAREE ENERGIES LIMITED Bi-33-435 | 435.0 W | 404.3 W | 49.59 V | 41.21 V | 19.68% |
| WAAREE ENERGIES LIMITED Bi-33-440 | 440.0 W | 409.1 W | 49.69 V | 41.41 V | 19.91% |
| WAAREE ENERGIES LIMITED Bi-33-445 | 445.0 W | 413.8 W | 49.89 V | 41.61 V | 20.14% |
How Many WAAREE ENERGIES LIMITED Bi-33-435 Modules Fit in a Cold-Weather String?
Maximum series module counts for WAAREE ENERGIES LIMITED Bi-33-435 from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 54.86 V | 10 panels | 548.6 V | 18 panels |
| -10 C (14 F) | 53.69 V | 11 panels | 590.6 V | 18 panels |
| 0 C (32 F) | 52.52 V | 11 panels | 577.7 V | 19 panels |
| 25 C (77 F STC) | 49.59 V | 12 panels | 595.1 V | 20 panels |
Which Cross-Brand Solar Modules Compare Closest to WAAREE ENERGIES LIMITED Bi-33-435?
Alternative CEC solar modules from competing brands near WAAREE ENERGIES LIMITED Bi-33-435 (435.0 W), including Aptos Solar Technology LLC DNA-144-BF26-435W.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Aptos Solar Technology LLC DNA-144-BF26-435W Aptos Solar Technology LLC |
435.0 W | Tie (0 W) | 49.38 V | 20.71% | 92.3% |
| Caterpillar Inc PVC435MB03H Caterpillar Inc |
435.0 W | Tie (0 W) | 49.1 V | 20.62% | 93.7% |
| CSI Solar Co Ltd CS3W-435PB-AG CSI Solar Co Ltd |
435.0 W | Tie (0 W) | 48.6 V | 20.05% | 93.4% |
| CSI Solar Co Ltd CS3W-435MB-AG CSI Solar Co Ltd |
435.0 W | Tie (0 W) | 48.5 V | 20.14% | 92.8% |
What Are the Design Limits and Best-Fit Uses for WAAREE ENERGIES LIMITED Bi-33-435?
Evaluate WAAREE ENERGIES LIMITED Bi-33-435 (435.0 W STC, 49.59 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), WAAREE ENERGIES LIMITED Bi-33-435 reaches 54.86 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 19 panels for an 8 kW build require 452 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 19 panels (452 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of WAAREE ENERGIES LIMITED Bi-33-435 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
WAAREE ENERGIES LIMITED Bi-33-435 8 kW Residential Fit
Needs 19 modules (452 sq ft) with a 20 A string OCPD, offsetting ~$2,070/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare Aptos Solar Technology LLC DNA-144-BF26-435W.
Bifacial / High-Heat Roof Check
Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 404.3 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for WAAREE ENERGIES LIMITED Bi-33-435 by WAAREE ENERGIES LIMITED grounded in CEC test data and NEC 690.7/690.8 limits.
Why is WAAREE ENERGIES LIMITED Bi-33-435 PTC wattage (404.3 W) lower than STC (435.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 404.3 W PTC (92.9% retention) across WAAREE ENERGIES LIMITED Bi-33-435's 2.21 m2 aperture.
Who should skip WAAREE ENERGIES LIMITED Bi-33-435 on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 19 WAAREE ENERGIES LIMITED Bi-33-435 panels (452 sq ft) leave unusable roof gaps vs. Aptos Solar Technology LLC DNA-144-BF26-435W.
What is the 1,000 V commercial string limit for WAAREE ENERGIES LIMITED Bi-33-435?
On 1,000 V commercial inverters at -10 C (53.69 V cold Voc), WAAREE ENERGIES LIMITED Bi-33-435 fits up to 18 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting WAAREE ENERGIES LIMITED Bi-33-435.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)