WAAREE ENERGIES LIMITED Bi-31-440 is a 440.0 W STC (412.0 W PTC) Mono-c-Si solar module ranking #6,418 of 21,677 CEC listings (top 31.6%; higher than 68.4% of peers). It delivers 20.4% efficiency, 49.69 V Voc at 25 C, and 54.11 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 440.0 W
- PTC Wattage
- 412.0 W
- Voc @ 25C
- 49.69 V
- Efficiency
- 20.4%
How Does WAAREE ENERGIES LIMITED Bi-31-440 Compare Against Peer CEC Listings?
Solar engineering breakdown for WAAREE ENERGIES LIMITED Bi-31-440: PTC thermal retention, roof footprint, and cold Voc string bounds.
Across 5,889 Mono-c-Si listings from WAAREE ENERGIES LIMITED and peers, WAAREE ENERGIES LIMITED Bi-31-440 stands 30.0 W above the 410.0 W Mono-c-Si median and strong 93.6% PTC-to-STC heat retention (#6,726 of 21,677). Sizing 6 kW (14 panels) to 10 kW (23 panels) yields $1,542-$2,533/yr in baseline US bill offset. Higher 49.69 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C).
Where Does WAAREE ENERGIES LIMITED Bi-31-440 Fall Across Listed CEC Models?
Distribution marker showing WAAREE ENERGIES LIMITED Bi-31-440 (440.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define WAAREE ENERGIES LIMITED Bi-31-440?
Dataset percentiles tracking WAAREE ENERGIES LIMITED Bi-31-440 power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for WAAREE ENERGIES LIMITED Bi-31-440?
Benchmark highlights for WAAREE ENERGIES LIMITED Bi-31-440 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
Top 31.6% STC Output
440.0 W STC (+55.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
20.4% Aperture Efficiency
Power density 204.0 W/m2 (0.49 percentage points above 19.91% CEC median). PTC/STC ratio: 93.6% (rank #6,726).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 54.11 V at -10 C (595.2 V string) and 55.37 V at -20 C (10 max).
19 Panels = 8,360 W STC
Occupies 41.0 m2 (441 sq ft) producing 7,828 W PTC; NEC 690.8 OCPD floor is 17.69 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 49.69 * (1 + (-0.254/100) * (-10 - 25)) = 54.11 V | OCPD = 1.56 * 11.34 = 17.69 A
Inputs from CEC Modules.csv for WAAREE ENERGIES LIMITED Bi-31-440: Voc=49.69 V, beta_Voc=-0.254%/C, Isc=11.34 A, STC=440.0 W, Area=2.157 m2.
Result: 11 panels max on 600 V (595.2 V); 19 panels for 8 kW (441 sq ft).
What Are the Published CEC Specifications for WAAREE ENERGIES LIMITED Bi-31-440?
Official CEC datasheet figures for WAAREE ENERGIES LIMITED Bi-31-440 (Mono-c-Si) used in utility interconnection and permit reviews. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 440.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 412.0 W (93.6% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 49.69 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 11.34 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 41.41 V / 10.63 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.254 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 20.4% (2.157 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Bifacial glass-glass |
How Many WAAREE ENERGIES LIMITED Bi-31-440 Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many WAAREE ENERGIES LIMITED Bi-31-440 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 14 | 6.16 kW | 325 sq ft | $1,542 | $2,607 |
| 8 kW Class | 19 | 8.36 kW | 441 sq ft | $2,092 | $3,538 |
| 10 kW Class | 23 | 10.12 kW | 534 sq ft | $2,533 | $4,283 |
Which Sibling Wattage & Trim Variants Belong to This WAAREE ENERGIES LIMITED Series?
Consolidated WAAREE ENERGIES LIMITED wattage variants sharing the WAAREE ENERGIES LIMITED Bi-31-440 mechanical and cell layout. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| WAAREE ENERGIES LIMITED Bi-31-430 | 430.0 W | 402.4 W | 49.39 V | 41.01 V | 19.94% |
| WAAREE ENERGIES LIMITED Bi-31-435 | 435.0 W | 407.2 W | 49.59 V | 41.21 V | 20.17% |
| WAAREE ENERGIES LIMITED Bi-31-440 | 440.0 W | 412.0 W | 49.69 V | 41.41 V | 20.4% |
| WAAREE ENERGIES LIMITED Bi-31-445 | 445.0 W | 416.8 W | 49.89 V | 41.61 V | 20.63% |
How Many WAAREE ENERGIES LIMITED Bi-31-440 Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on WAAREE ENERGIES LIMITED Bi-31-440 (54.11 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 55.37 V | 10 panels | 553.7 V | 18 panels |
| -10 C (14 F) | 54.11 V | 11 panels | 595.2 V | 18 panels |
| 0 C (32 F) | 52.85 V | 11 panels | 581.4 V | 18 panels |
| 25 C (77 F STC) | 49.69 V | 12 panels | 596.3 V | 20 panels |
Which Cross-Brand Solar Modules Compare Closest to WAAREE ENERGIES LIMITED Bi-31-440?
Competing CEC solar panels closest to WAAREE ENERGIES LIMITED Bi-31-440 in nameplate wattage and Voc, starting with Bluesun Solar CoLtd BSM440M-72HBD.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Bluesun Solar CoLtd BSM440M-72HBD Bluesun Solar CoLtd |
440.0 W | Tie (0 W) | 50.0 V | 20.28% | 92.7% |
| CSI Solar Co Ltd CS3Y-440PB-AG CSI Solar Co Ltd |
440.0 W | Tie (0 W) | 51.2 V | 19.13% | 93.7% |
| Aptos Solar Technology LLC DNA-144-BF26-435W Aptos Solar Technology LLC |
435.0 W | -5.0 W | 49.38 V | 20.71% | 92.3% |
| Caterpillar Inc PVC435MB03H Caterpillar Inc |
435.0 W | -5.0 W | 49.1 V | 20.62% | 93.7% |
What Are the Design Limits and Best-Fit Uses for WAAREE ENERGIES LIMITED Bi-31-440?
Evaluate WAAREE ENERGIES LIMITED Bi-31-440 (440.0 W STC, 49.69 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), WAAREE ENERGIES LIMITED Bi-31-440 reaches 55.37 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 19 panels for an 8 kW build require 441 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 19 panels (441 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of WAAREE ENERGIES LIMITED Bi-31-440 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
WAAREE ENERGIES LIMITED Bi-31-440 8 kW Residential Fit
Needs 19 modules (441 sq ft) with a 20 A string OCPD, offsetting ~$2,092/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare Bluesun Solar CoLtd BSM440M-72HBD.
Bifacial / High-Heat Roof Check
Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 412.0 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for WAAREE ENERGIES LIMITED Bi-31-440 by WAAREE ENERGIES LIMITED grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for WAAREE ENERGIES LIMITED Bi-31-440?
Multiplying WAAREE ENERGIES LIMITED Bi-31-440's 11.34 A short-circuit current by 1.56 equals 17.69 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.
Can WAAREE ENERGIES LIMITED Bi-31-440 pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 54.11 V cold Voc at 14 F and handles 11.34 A Isc; string inverters cap WAAREE ENERGIES LIMITED Bi-31-440 at 11 panels on 600 V.
Is WAAREE ENERGIES LIMITED Bi-31-440 eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of WAAREE ENERGIES LIMITED Bi-31-440 rely on utility bill offset (~$2,092/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)