Manufacturer: Vikram Solar Registry: CEC Verified Engineering Specification

Vikram Solar SOMERA VSMHBB6036505 is a 365.0 W STC (337.1 W PTC) Mono-c-Si solar module ranking #12,044 of 21,677 CEC listings (below all-CEC median; higher than 42.9% of peers). It delivers 19.62% efficiency, 41.0 V Voc at 25 C, and 45.13 V cold Voc at -10 C (13 panels max per 600 V string).

STC Wattage
365.0 W
PTC Wattage
337.1 W
Voc @ 25C
41.0 V
Efficiency
19.62%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Vikram Solar SOMERA VSMHBB6036505 Compare Against Peer CEC Listings?

Engineering position of Vikram Solar SOMERA VSMHBB6036505 (365.0 W STC) vs. Caterpillar Inc PVC365MP03HA across 5,889 CEC Mono-c-Si solar modules.

Built with 60 Mono-c-Si cells, Vikram Solar SOMERA VSMHBB6036505 pairs strong 92.4% PTC-to-STC heat retention (#12,969 of 21,677) with 41.0 V nominal Voc. An 8 kW residential build (8,030 W DC, 7,416 W PTC) saves ~$2,010/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer Caterpillar Inc PVC365MP03HA offers a 365.0 W alternative.

Where Does Vikram Solar SOMERA VSMHBB6036505 Fall Across Listed CEC Models?

Plots Vikram Solar SOMERA VSMHBB6036505 at 365.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Vikram Solar SOMERA VSMHBB6036505 (365.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCVikram Solar SOMER: 365.0 W

What Dataset Percentiles Define Vikram Solar SOMERA VSMHBB6036505?

Benchmarks Vikram Solar SOMERA VSMHBB6036505 on STC wattage, thermal PTC/STC retention, and 19.62 aperture conversion efficiency against CEC peers.

Vikram Solar SOMERA VSMHBB6036505 Engineering BenchmarksPercentile comparison of Vikram Solar SOMERA VSMHBB6036505 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage365.0 WPTC/STC Retention92.4%Module Efficiency19.62%

What Do the Dataset Ranks Show for Vikram Solar SOMERA VSMHBB6036505?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Vikram Solar SOMERA VSMHBB6036505 by Vikram Solar.

Rank #12,044 / 21,677

365.0 W STC · Higher Than 42.9%

365.0 W STC (-20.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #11,803

19.62% Aperture Efficiency

Power density 196.2 W/m2 (0.29 percentage points below 19.91% CEC median). PTC/STC ratio: 92.4% (rank #12,969).

NEC 690.7 Limit

13 Panels Max @ -10 C (600 V)

Cold Voc reaches 45.13 V at -10 C (586.7 V string) and 46.31 V at -20 C (12 max).

8 kW Reference Array

22 Panels = 8,030 W STC

Occupies 40.9 m2 (440 sq ft) producing 7,416 W PTC; NEC 690.8 OCPD floor is 17.86 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 41.0 * (1 + (-0.288/100) * (-10 - 25)) = 45.13 V | OCPD = 1.56 * 11.45 = 17.86 A

Inputs from CEC Modules.csv for Vikram Solar SOMERA VSMHBB6036505: Voc=41.0 V, beta_Voc=-0.288%/C, Isc=11.45 A, STC=365.0 W, Area=1.86 m2.

Result: 13 panels max on 600 V (586.7 V); 22 panels for 8 kW (440 sq ft).

What Are the Published CEC Specifications for Vikram Solar SOMERA VSMHBB6036505?

Laboratory test ratings recorded for Vikram Solar SOMERA VSMHBB6036505 (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for Vikram Solar SOMERA VSMHBB6036505.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 365.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 337.1 W (92.4% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 41.0 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 11.45 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 34.8 V / 10.53 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.288 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 19.62% (1.86 m2) Array roof footprint density
Cell Count & Technology 60 cells (Mono-c-Si) Monofacial backsheet

How Many Vikram Solar SOMERA VSMHBB6036505 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (440 sq ft at 8 kW), and estimated Year-1 electric bill offset for Vikram Solar SOMERA VSMHBB6036505.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 17 6.21 kW 340 sq ft $1,554 $2,628
8 kW Class 22 8.03 kW 440 sq ft $2,010 $3,398
10 kW Class 28 10.22 kW 561 sq ft $2,558 $4,325

How Many Vikram Solar SOMERA VSMHBB6036505 Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for Vikram Solar SOMERA VSMHBB6036505 (beta_Voc -0.288%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=41.0V and beta_Voc=-0.288%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 46.31 V 12 panels 555.7 V 21 panels
-10 C (14 F) 45.13 V 13 panels 586.7 V 22 panels
0 C (32 F) 43.95 V 13 panels 571.4 V 22 panels
25 C (77 F STC) 41.0 V 14 panels 574.0 V 24 panels

Which Cross-Brand Solar Modules Compare Closest to Vikram Solar SOMERA VSMHBB6036505?

Closest cross-brand CEC competitors to Vikram Solar SOMERA VSMHBB6036505 matched near 365.0 W STC and 41.0 V Voc, led by Caterpillar Inc PVC365MP03HA.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Caterpillar Inc PVC365MP03HA
Caterpillar Inc
365.0 W Tie (0 W) 41.0 V 20.62% 93.5%
Bluesun Solar CoLtd BSM365M-60HPH
Bluesun Solar CoLtd
365.0 W Tie (0 W) 40.9 V 20.05% 92.8%
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-365W
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd
365.0 W Tie (0 W) 40.7 V 20.51% 92.6%
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-HC-365W
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd
365.0 W Tie (0 W) 40.7 V 20.17% 92.3%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Vikram Solar SOMERA VSMHBB6036505?

Evaluate Vikram Solar SOMERA VSMHBB6036505 (365.0 W STC, 41.0 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Vikram Solar SOMERA VSMHBB6036505 reaches 46.31 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 22 panels for an 8 kW build require 440 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 22 panels (440 sq ft).
  • 2026 tax credit baseline: cash residential installs of Vikram Solar SOMERA VSMHBB6036505 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Vikram Solar SOMERA VSMHBB6036505 8 kW Residential Fit

Needs 22 modules (440 sq ft) with a 20 A string OCPD, offsetting ~$2,010/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 12 panels (-20 C), or compare Caterpillar Inc PVC365MP03HA.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 337.1 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Vikram Solar SOMERA VSMHBB6036505 by Vikram Solar grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for Vikram Solar SOMERA VSMHBB6036505?

Multiplying Vikram Solar SOMERA VSMHBB6036505's 11.45 A short-circuit current by 1.56 equals 17.86 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.

Can Vikram Solar SOMERA VSMHBB6036505 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 45.13 V cold Voc at 14 F and handles 11.45 A Isc; string inverters cap Vikram Solar SOMERA VSMHBB6036505 at 13 panels on 600 V.

Is Vikram Solar SOMERA VSMHBB6036505 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Vikram Solar SOMERA VSMHBB6036505 rely on utility bill offset (~$2,010/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.