Vikram Solar SOMERA VSM7238005 is a 380.0 W STC (349.9 W PTC) Mono-c-Si solar module ranking #11,043 of 21,677 CEC listings (below all-CEC median; higher than 47.6% of peers). It delivers 20.21% efficiency, 48.9 V Voc at 25 C, and 54.09 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 380.0 W
- PTC Wattage
- 349.9 W
- Voc @ 25C
- 48.9 V
- Efficiency
- 20.21%
How Does Vikram Solar SOMERA VSM7238005 Compare Against Peer CEC Listings?
Engineering position of Vikram Solar SOMERA VSM7238005 (380.0 W STC) vs. Caterpillar Inc PVC380MP03H across 5,889 CEC Mono-c-Si solar modules.
Ranking #11,043 across 21,677 CEC solar panels (below all-CEC median; higher than 47.6% of peers), Vikram Solar SOMERA VSM7238005 operates as a compact residential or specialty off-grid module sitting 30.0 W below the 410.0 W Mono-c-Si median. Higher 48.9 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C). With strong 92.1% PTC-to-STC heat retention (#13,846 of 21,677), 22 panels occupy 445 sq ft and offset roughly $2,092/yr at average US rates (or $3,538/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.
Where Does Vikram Solar SOMERA VSM7238005 Fall Across Listed CEC Models?
Plots Vikram Solar SOMERA VSM7238005 at 380.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.
What Dataset Percentiles Define Vikram Solar SOMERA VSM7238005?
Benchmarks Vikram Solar SOMERA VSM7238005 on STC wattage, thermal PTC/STC retention, and 20.21 aperture conversion efficiency against CEC peers.
What Do the Dataset Ranks Show for Vikram Solar SOMERA VSM7238005?
Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Vikram Solar SOMERA VSM7238005 by Vikram Solar.
380.0 W STC · Higher Than 47.6%
380.0 W STC (-5.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
20.21% Aperture Efficiency
Power density 202.1 W/m2 (0.30 percentage points above 19.91% CEC median). PTC/STC ratio: 92.1% (rank #13,846).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 54.09 V at -10 C (595.0 V string) and 55.57 V at -20 C (10 max).
22 Panels = 8,360 W STC
Occupies 41.4 m2 (445 sq ft) producing 7,698 W PTC; NEC 690.8 OCPD floor is 15.66 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 48.9 * (1 + (-0.303/100) * (-10 - 25)) = 54.09 V | OCPD = 1.56 * 10.04 = 15.66 A
Inputs from CEC Modules.csv for Vikram Solar SOMERA VSM7238005: Voc=48.9 V, beta_Voc=-0.303%/C, Isc=10.04 A, STC=380.0 W, Area=1.88 m2.
Result: 11 panels max on 600 V (595.0 V); 22 panels for 8 kW (445 sq ft).
What Are the Published CEC Specifications for Vikram Solar SOMERA VSM7238005?
Laboratory test ratings recorded for Vikram Solar SOMERA VSM7238005 (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 380.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 349.9 W (92.1% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 48.9 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 10.04 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 40.26 V / 9.45 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.303 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 20.21% (1.88 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Monofacial backsheet |
How Many Vikram Solar SOMERA VSM7238005 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Panel counts, roof square footage (445 sq ft at 8 kW), and estimated Year-1 electric bill offset for Vikram Solar SOMERA VSM7238005.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 16 | 6.08 kW | 324 sq ft | $1,522 | $2,573 |
| 8 kW Class | 22 | 8.36 kW | 445 sq ft | $2,092 | $3,538 |
| 10 kW Class | 27 | 10.26 kW | 546 sq ft | $2,568 | $4,342 |
How Many Vikram Solar SOMERA VSM7238005 Modules Fit in a Cold-Weather String?
Cold-weather Voc escalation for Vikram Solar SOMERA VSM7238005 (beta_Voc -0.303%/C) across 600 V residential and 1,000 V commercial inverters.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 55.57 V | 10 panels | 555.7 V | 17 panels |
| -10 C (14 F) | 54.09 V | 11 panels | 595.0 V | 18 panels |
| 0 C (32 F) | 52.6 V | 11 panels | 578.6 V | 19 panels |
| 25 C (77 F STC) | 48.9 V | 12 panels | 586.8 V | 20 panels |
Which Cross-Brand Solar Modules Compare Closest to Vikram Solar SOMERA VSM7238005?
Closest cross-brand CEC competitors to Vikram Solar SOMERA VSM7238005 matched near 380.0 W STC and 48.9 V Voc, led by Caterpillar Inc PVC380MP03H.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Caterpillar Inc PVC380MP03H Caterpillar Inc |
380.0 W | Tie (0 W) | 49.0 V | 19.63% | 94.1% |
| Crossroads Solar Crossroads Solar 380 Crossroads Solar |
380.0 W | Tie (0 W) | 49.0 V | 18.63% | 92.2% |
| Caterpillar Inc PVC380MP03 Caterpillar Inc |
380.0 W | Tie (0 W) | 49.03 V | 20.21% | 93.5% |
| Bluesun Solar Energy Tech CoLtd BSM380M-72 Bluesun Solar Energy Tech CoLtd |
380.0 W | Tie (0 W) | 48.67 V | 19.59% | 92.0% |
What Are the Design Limits and Best-Fit Uses for Vikram Solar SOMERA VSM7238005?
Evaluate Vikram Solar SOMERA VSM7238005 (380.0 W STC, 48.9 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Vikram Solar SOMERA VSM7238005 reaches 55.57 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 22 panels for an 8 kW build require 445 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 22 panels (445 sq ft).
- 2026 tax credit baseline: cash residential installs of Vikram Solar SOMERA VSM7238005 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Vikram Solar SOMERA VSM7238005 8 kW Residential Fit
Needs 22 modules (445 sq ft) with a 20 A string OCPD, offsetting ~$2,092/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare Caterpillar Inc PVC380MP03H.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 349.9 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Vikram Solar SOMERA VSM7238005 by Vikram Solar grounded in CEC test data and NEC 690.7/690.8 limits.
How many Vikram Solar SOMERA VSM7238005 panels fit on a 600 V winter solar string?
At -10 C (14 F), Vikram Solar SOMERA VSM7238005 cold Voc rises from 48.9 V to 54.09 V (beta_Voc -0.303%/C), capping a 600 V string at 11 panels (595.0 V).
How much roof area does an 8 kW array of Vikram Solar SOMERA VSM7238005 need?
An 8 kW DC system uses 22 Vikram Solar SOMERA VSM7238005 modules (8,360 W STC / 7,698 W PTC), covering roughly 445 sq ft and saving ~$2,092/yr at 18.54 c/kWh.
How does Vikram Solar SOMERA VSM7238005 compare against Caterpillar Inc PVC380MP03H?
Vikram Solar SOMERA VSM7238005 outputs 380.0 W STC (48.9 V Voc, rank #11,043 of 21,677), while Caterpillar Inc PVC380MP03H delivers 380.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)