Manufacturer: United Renewable Energy Co Ltd Registry: CEC Verified Engineering Specification

United Renewable Energy Co Ltd D6M290B4AME is a 290.0 W STC (255.9 W PTC) Mono-c-Si solar module ranking #17,253 of 21,677 CEC listings (below all-CEC median; higher than 18.8% of peers). It delivers 14.87% efficiency, 44.44 V Voc at 25 C, and 50.66 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
290.0 W
PTC Wattage
255.9 W
Voc @ 25C
44.44 V
Efficiency
14.87%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does United Renewable Energy Co Ltd D6M290B4AME Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for United Renewable Energy Co Ltd D6M290B4AME (Mono-c-Si) residential solar systems.

Homeowners evaluating United Renewable Energy Co Ltd D6M290B4AME need 21 panels for 6 kW or 28 panels (588 sq ft) for an 8 kW array—useful on tight dormer roofs or battery cabins, though 8 kW requires 28 panels (588 sq ft). Under NEC 690.7(A), beta_Voc (-0.4%/C) pushes open-circuit voltage to 50.66 V at 14 F and 52.44 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

Where Does United Renewable Energy Co Ltd D6M290B4AME Fall Across Listed CEC Models?

Comparison of United Renewable Energy Co Ltd D6M290B4AME (290.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where United Renewable Energy Co Ltd D6M290B4AME (290.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCUnited Renewable E: 290.0 W

What Dataset Percentiles Define United Renewable Energy Co Ltd D6M290B4AME?

Relative ranking of United Renewable Energy Co Ltd D6M290B4AME across nameplate watts, 88.2% PTC thermal ratio, and module aperture efficiency.

United Renewable Energy Co Ltd D6M290B4AME Engineering BenchmarksPercentile comparison of United Renewable Energy Co Ltd D6M290B4AME wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage290.0 WPTC/STC Retention88.2%Module Efficiency14.87%

What Do the Dataset Ranks Show for United Renewable Energy Co Ltd D6M290B4AME?

Summary of United Renewable Energy Co Ltd D6M290B4AME output rank, 8 kW array size (28 panels), efficiency rating, and 600 V string limit.

Rank #17,253 / 21,677

290.0 W STC · Higher Than 18.8%

290.0 W STC (-95.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #19,920

14.87% Aperture Efficiency

Power density 148.7 W/m2 (5.04 percentage points below 19.91% CEC median). PTC/STC ratio: 88.2% (rank #21,309).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 50.66 V at -10 C (557.3 V string) and 52.44 V at -20 C (11 max).

8 kW Reference Array

28 Panels = 8,120 W STC

Occupies 54.6 m2 (588 sq ft) producing 7,165 W PTC; NEC 690.8 OCPD floor is 13.67 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 44.44 * (1 + (-0.4/100) * (-10 - 25)) = 50.66 V | OCPD = 1.56 * 8.76 = 13.67 A

Inputs from CEC Modules.csv for United Renewable Energy Co Ltd D6M290B4AME: Voc=44.44 V, beta_Voc=-0.4%/C, Isc=8.76 A, STC=290.0 W, Area=1.95 m2.

Result: 11 panels max on 600 V (557.3 V); 28 panels for 8 kW (588 sq ft).

What Are the Published CEC Specifications for United Renewable Energy Co Ltd D6M290B4AME?

Complete CEC test sheet for United Renewable Energy Co Ltd D6M290B4AME including Isc (8.76 A), Voc (44.44 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for United Renewable Energy Co Ltd D6M290B4AME.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 290.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 255.9 W (88.2% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 44.44 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.76 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 35.96 V / 8.07 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.4 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 14.87% (1.95 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Monofacial backsheet

How Many United Renewable Energy Co Ltd D6M290B4AME Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using United Renewable Energy Co Ltd D6M290B4AME.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 21 6.09 kW 441 sq ft $1,524 $2,577
8 kW Class 28 8.12 kW 588 sq ft $2,032 $3,437
10 kW Class 35 10.15 kW 735 sq ft $2,540 $4,296

Which Sibling Wattage & Trim Variants Belong to This United Renewable Energy Co Ltd Series?

Related United Renewable Energy Co Ltd power steps and black/silver trims consolidated into this United Renewable Energy Co Ltd D6M290B4AME series guide.

Sibling CEC listings grouped into the United Renewable Energy Co Ltd D6M290B4AME wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
United Renewable Energy Co Ltd D6M285B4AME 285.0 W 251.3 W 43.93 V 35.48 V 14.61%
United Renewable Energy Co Ltd D6M290B4AME 290.0 W 255.9 W 44.44 V 35.96 V 14.87%
United Renewable Energy Co Ltd D6M295B4AME 295.0 W 260.4 W 44.94 V 36.44 V 15.13%

How Many United Renewable Energy Co Ltd D6M290B4AME Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for United Renewable Energy Co Ltd D6M290B4AME (44.44 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=44.44V and beta_Voc=-0.4%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 52.44 V 11 panels 576.8 V 19 panels
-10 C (14 F) 50.66 V 11 panels 557.3 V 19 panels
0 C (32 F) 48.88 V 12 panels 586.6 V 20 panels
25 C (77 F STC) 44.44 V 13 panels 577.7 V 22 panels

Which Cross-Brand Solar Modules Compare Closest to United Renewable Energy Co Ltd D6M290B4AME?

Four comparable CEC modules such as Centrosolar America DM72 290 (290.0 W) for side-by-side solar quote checks. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Centrosolar America DM72 290
Centrosolar America
290.0 W Tie (0 W) 44.4 V 14.92% 90.6%
Gintung Energy GTEC-290G6M
Gintung Energy
290.0 W Tie (0 W) 44.61 V 14.83% 89.6%
Gintung Energy GTEC-290G6S
Gintung Energy
290.0 W Tie (0 W) 44.84 V 14.83% 89.7%
AXITEC AC-290M/156-72S
AXITEC
290.0 W Tie (0 W) 44.98 V 14.95% 90.6%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for United Renewable Energy Co Ltd D6M290B4AME?

Evaluate United Renewable Energy Co Ltd D6M290B4AME (290.0 W STC, 44.44 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), United Renewable Energy Co Ltd D6M290B4AME reaches 52.44 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 28 panels for an 8 kW build require 588 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 28 panels (588 sq ft).
  • 2026 tax credit baseline: cash residential installs of United Renewable Energy Co Ltd D6M290B4AME carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

United Renewable Energy Co Ltd D6M290B4AME 8 kW Residential Fit

Needs 28 modules (588 sq ft) with a 15 A string OCPD, offsetting ~$2,032/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Centrosolar America DM72 290.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 255.9 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for United Renewable Energy Co Ltd D6M290B4AME by United Renewable Energy Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.

Why is United Renewable Energy Co Ltd D6M290B4AME PTC wattage (255.9 W) lower than STC (290.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 255.9 W PTC (88.2% retention) across United Renewable Energy Co Ltd D6M290B4AME's 1.95 m2 aperture.

Who should skip United Renewable Energy Co Ltd D6M290B4AME on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 28 United Renewable Energy Co Ltd D6M290B4AME panels (588 sq ft) leave unusable roof gaps vs. Centrosolar America DM72 290.

What is the 1,000 V commercial string limit for United Renewable Energy Co Ltd D6M290B4AME?

On 1,000 V commercial inverters at -10 C (50.66 V cold Voc), United Renewable Energy Co Ltd D6M290B4AME fits up to 19 panels per series string.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.