Manufacturer: TSEC Registry: CEC Verified Engineering Specification

TSEC TS60-AMH-365 H2 is a 365.0 W STC (337.8 W PTC) Mono-c-Si solar module ranking #12,044 of 21,677 CEC listings (below all-CEC median; higher than 42.9% of peers). It delivers 20.17% efficiency, 40.7 V Voc at 25 C, and 44.97 V cold Voc at -10 C (13 panels max per 600 V string).

STC Wattage
365.0 W
PTC Wattage
337.8 W
Voc @ 25C
40.7 V
Efficiency
20.17%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does TSEC TS60-AMH-365 H2 Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for TSEC TS60-AMH-365 H2 (Mono-c-Si) residential solar systems.

TSEC TS60-AMH-365 H2 delivers 201.7 W/m2 (0.26 percentage points above 19.91% CEC median) and strong 92.5% PTC-to-STC heat retention (#12,531 of 21,677), placing it as a compact residential or specialty off-grid module useful on tight dormer roofs or battery cabins, though 8 kW requires 22 panels (429 sq ft). At -4 F (-20 C), string voltage climbs to 46.19 V per unit, capping 600 V circuits at 12 panels. Compare specs directly with Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-365W (365.0 W).

Where Does TSEC TS60-AMH-365 H2 Fall Across Listed CEC Models?

Comparison of TSEC TS60-AMH-365 H2 (365.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where TSEC TS60-AMH-365 H2 (365.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCTSEC TS60-AMH-365 : 365.0 W

What Dataset Percentiles Define TSEC TS60-AMH-365 H2?

Relative ranking of TSEC TS60-AMH-365 H2 across nameplate watts, 92.5% PTC thermal ratio, and module aperture efficiency. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

TSEC TS60-AMH-365 H2 Engineering BenchmarksPercentile comparison of TSEC TS60-AMH-365 H2 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage365.0 WPTC/STC Retention92.5%Module Efficiency20.17%

What Do the Dataset Ranks Show for TSEC TS60-AMH-365 H2?

Summary of TSEC TS60-AMH-365 H2 output rank, 8 kW array size (22 panels), efficiency rating, and 600 V string limit.

Rank #12,044 / 21,677

365.0 W STC · Higher Than 42.9%

365.0 W STC (-20.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #9,881

20.17% Aperture Efficiency

Power density 201.7 W/m2 (0.26 percentage points above 19.91% CEC median). PTC/STC ratio: 92.5% (rank #12,531).

NEC 690.7 Limit

13 Panels Max @ -10 C (600 V)

Cold Voc reaches 44.97 V at -10 C (584.6 V string) and 46.19 V at -20 C (12 max).

8 kW Reference Array

22 Panels = 8,030 W STC

Occupies 39.8 m2 (429 sq ft) producing 7,432 W PTC; NEC 690.8 OCPD floor is 17.83 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 40.7 * (1 + (-0.3/100) * (-10 - 25)) = 44.97 V | OCPD = 1.56 * 11.43 = 17.83 A

Inputs from CEC Modules.csv for TSEC TS60-AMH-365 H2: Voc=40.7 V, beta_Voc=-0.3%/C, Isc=11.43 A, STC=365.0 W, Area=1.81 m2.

Result: 13 panels max on 600 V (584.6 V); 22 panels for 8 kW (429 sq ft).

What Are the Published CEC Specifications for TSEC TS60-AMH-365 H2?

Complete CEC test sheet for TSEC TS60-AMH-365 H2 including Isc (11.43 A), Voc (40.7 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for TSEC TS60-AMH-365 H2.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 365.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 337.8 W (92.5% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 40.7 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 11.43 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 34.2 V / 10.68 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.3 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 20.17% (1.81 m2) Array roof footprint density
Cell Count & Technology 60 cells (Mono-c-Si) Monofacial backsheet

How Many TSEC TS60-AMH-365 H2 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using TSEC TS60-AMH-365 H2.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 17 6.21 kW 331 sq ft $1,554 $2,628
8 kW Class 22 8.03 kW 429 sq ft $2,010 $3,398
10 kW Class 28 10.22 kW 546 sq ft $2,558 $4,325

Which Sibling Wattage & Trim Variants Belong to This TSEC Series?

Related TSEC power steps and black/silver trims consolidated into this TSEC TS60-AMH-365 H2 series guide. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Sibling CEC listings grouped into the TSEC TS60-AMH-365 H2 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
TSEC TS60-AMH-355 H2 355.0 W 328.3 W 40.3 V 33.8 V 19.61%
TSEC TS60-AMH-360 H2 360.0 W 333.0 W 40.5 V 34.0 V 19.89%
TSEC TS60-AMH-365 H2 365.0 W 337.8 W 40.7 V 34.2 V 20.17%
TSEC TS60-AMH-370 H2 370.0 W 342.5 W 40.9 V 34.4 V 20.44%

How Many TSEC TS60-AMH-365 H2 Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for TSEC TS60-AMH-365 H2 (40.7 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=40.7V and beta_Voc=-0.3%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 46.19 V 12 panels 554.3 V 21 panels
-10 C (14 F) 44.97 V 13 panels 584.6 V 22 panels
0 C (32 F) 43.75 V 13 panels 568.8 V 22 panels
25 C (77 F STC) 40.7 V 14 panels 569.8 V 24 panels

Which Cross-Brand Solar Modules Compare Closest to TSEC TS60-AMH-365 H2?

Four comparable CEC modules such as Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-365W (365.0 W) for side-by-side solar quote checks.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-365W
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd
365.0 W Tie (0 W) 40.7 V 20.51% 92.6%
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-HC-365W
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd
365.0 W Tie (0 W) 40.7 V 20.17% 92.3%
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-HC-365W Black
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd
365.0 W Tie (0 W) 40.7 V 19.95% 93.3%
Aptos Solar Technology LLC DNA-120-MF26-365W
Aptos Solar Technology LLC
365.0 W Tie (0 W) 40.7 V 20.74% 91.3%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for TSEC TS60-AMH-365 H2?

Evaluate TSEC TS60-AMH-365 H2 (365.0 W STC, 40.7 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), TSEC TS60-AMH-365 H2 reaches 46.19 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 22 panels for an 8 kW build require 429 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 22 panels (429 sq ft).
  • 2026 tax credit baseline: cash residential installs of TSEC TS60-AMH-365 H2 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

TSEC TS60-AMH-365 H2 8 kW Residential Fit

Needs 22 modules (429 sq ft) with a 20 A string OCPD, offsetting ~$2,010/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 12 panels (-20 C), or compare Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-365W.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 337.8 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for TSEC TS60-AMH-365 H2 by TSEC grounded in CEC test data and NEC 690.7/690.8 limits.

How many TSEC TS60-AMH-365 H2 panels fit on a 600 V winter solar string?

At -10 C (14 F), TSEC TS60-AMH-365 H2 cold Voc rises from 40.7 V to 44.97 V (beta_Voc -0.3%/C), capping a 600 V string at 13 panels (584.6 V).

How much roof area does an 8 kW array of TSEC TS60-AMH-365 H2 need?

An 8 kW DC system uses 22 TSEC TS60-AMH-365 H2 modules (8,030 W STC / 7,432 W PTC), covering roughly 429 sq ft and saving ~$2,010/yr at 18.54 c/kWh.

How does TSEC TS60-AMH-365 H2 compare against Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-365W?

TSEC TS60-AMH-365 H2 outputs 365.0 W STC (40.7 V Voc, rank #12,044 of 21,677), while Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-365W delivers 365.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.