TSEC TS66-BMH-490 H1 is a 490.0 W STC (454.2 W PTC) Mono-c-Si solar module ranking #4,659 of 21,677 CEC listings (top 21.8%; higher than 78.2% of peers). It delivers 20.85% efficiency, 45.25 V Voc at 25 C, and 49.84 V cold Voc at -10 C (12 panels max per 600 V string).
- STC Wattage
- 490.0 W
- PTC Wattage
- 454.2 W
- Voc @ 25C
- 45.25 V
- Efficiency
- 20.85%
How Does TSEC TS66-BMH-490 H1 Compare Against Peer CEC Listings?
Solar engineering breakdown for TSEC TS66-BMH-490 H1: PTC thermal retention, roof footprint, and cold Voc string bounds. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.
Measured at 490.0 W STC and 454.2 W PTC, TSEC TS66-BMH-490 H1 sits +105.0 W vs all-CEC median (top 21.8%; higher than 78.2% of peers) among 21,677 listed modules. Power density reaches 208.5 W/m2 (0.94 percentage points above 19.91% CEC median). Mid-range 45.25 V open-circuit voltage allows up to 12 panels per 600 V string at 14 F, whereas 1,000 V commercial inverters handle up to 20 panels in series. Alternative peer DONGGUAN SUNWORTH SOLAR ENERGY CO LTD SW490M rates 490.0 W.
Where Does TSEC TS66-BMH-490 H1 Fall Across Listed CEC Models?
Distribution marker showing TSEC TS66-BMH-490 H1 (490.0 W) relative to the 385.0 W all-CEC solar panel median. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.
What Dataset Percentiles Define TSEC TS66-BMH-490 H1?
Dataset percentiles tracking TSEC TS66-BMH-490 H1 power output, thermal retention ratio, and aperture efficiency against 21,677 models. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.
What Do the Dataset Ranks Show for TSEC TS66-BMH-490 H1?
Benchmark highlights for TSEC TS66-BMH-490 H1 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.
Top 21.8% STC Output
490.0 W STC (+105.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
20.85% Aperture Efficiency
Power density 208.5 W/m2 (0.94 percentage points above 19.91% CEC median). PTC/STC ratio: 92.7% (rank #11,468).
12 Panels Max @ -10 C (600 V)
Cold Voc reaches 49.84 V at -10 C (598.1 V string) and 51.16 V at -20 C (11 max).
17 Panels = 8,330 W STC
Occupies 40.0 m2 (430 sq ft) producing 7,721 W PTC; NEC 690.8 OCPD floor is 21.43 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 45.25 * (1 + (-0.29/100) * (-10 - 25)) = 49.84 V | OCPD = 1.56 * 13.74 = 21.43 A
Inputs from CEC Modules.csv for TSEC TS66-BMH-490 H1: Voc=45.25 V, beta_Voc=-0.29%/C, Isc=13.74 A, STC=490.0 W, Area=2.35 m2.
Result: 12 panels max on 600 V (598.1 V); 17 panels for 8 kW (430 sq ft).
What Are the Published CEC Specifications for TSEC TS66-BMH-490 H1?
Official CEC datasheet figures for TSEC TS66-BMH-490 H1 (Mono-c-Si) used in utility interconnection and permit reviews. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 490.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 454.2 W (92.7% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 45.25 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 13.74 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 38.08 V / 12.87 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.29 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 20.85% (2.35 m2) | Array roof footprint density |
| Cell Count & Technology | 66 cells (Mono-c-Si) | Monofacial backsheet |
How Many TSEC TS66-BMH-490 H1 Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many TSEC TS66-BMH-490 H1 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 13 | 6.37 kW | 329 sq ft | $1,594 | $2,696 |
| 8 kW Class | 17 | 8.33 kW | 430 sq ft | $2,085 | $3,525 |
| 10 kW Class | 21 | 10.29 kW | 531 sq ft | $2,575 | $4,355 |
Which Sibling Wattage & Trim Variants Belong to This TSEC Series?
Consolidated TSEC wattage variants sharing the TSEC TS66-BMH-490 H1 mechanical and cell layout. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| TSEC TS66-BMH-480 H1 | 480.0 W | 444.7 W | 44.95 V | 37.78 V | 20.43% |
| TSEC TS66-BMH-485 H1 | 485.0 W | 449.4 W | 45.1 V | 37.93 V | 20.64% |
| TSEC TS66-BMH-490 H1 | 490.0 W | 454.2 W | 45.25 V | 38.08 V | 20.85% |
| TSEC TS66-BMH-495 H1 | 495.0 W | 459.0 W | 45.4 V | 38.23 V | 21.06% |
How Many TSEC TS66-BMH-490 H1 Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on TSEC TS66-BMH-490 H1 (49.84 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 51.16 V | 11 panels | 562.8 V | 19 panels |
| -10 C (14 F) | 49.84 V | 12 panels | 598.1 V | 20 panels |
| 0 C (32 F) | 48.53 V | 12 panels | 582.4 V | 20 panels |
| 25 C (77 F STC) | 45.25 V | 13 panels | 588.2 V | 22 panels |
Which Cross-Brand Solar Modules Compare Closest to TSEC TS66-BMH-490 H1?
Competing CEC solar panels closest to TSEC TS66-BMH-490 H1 in nameplate wattage and Voc, starting with DONGGUAN SUNWORTH SOLAR ENERGY CO LTD SW490M.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| DONGGUAN SUNWORTH SOLAR ENERGY CO LTD SW490M DONGGUAN SUNWORTH SOLAR ENERGY CO LTD |
490.0 W | Tie (0 W) | 44.21 V | 25.79% | 95.0% |
| Elin Energy (Sirius PV) ELNSM66M-HC-495 Elin Energy (Sirius PV) |
495.0 W | +5.0 W | 45.45 V | 20.97% | 94.3% |
| Elin Energy (Sirius PV) ELNSM66M-HC-LV-495 Elin Energy (Sirius PV) |
495.0 W | +5.0 W | 45.45 V | 20.97% | 94.3% |
| Heliene 132HC-485 M10 SL Heliene |
485.0 W | -5.0 W | 45.77 V | 21.18% | 94.3% |
What Are the Design Limits and Best-Fit Uses for TSEC TS66-BMH-490 H1?
Evaluate TSEC TS66-BMH-490 H1 (490.0 W STC, 45.25 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), TSEC TS66-BMH-490 H1 reaches 51.16 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 17 panels for an 8 kW build require 430 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 17 panels (430 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of TSEC TS66-BMH-490 H1 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
TSEC TS66-BMH-490 H1 8 kW Residential Fit
Needs 17 modules (430 sq ft) with a 25 A string OCPD, offsetting ~$2,085/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 12 panels (-10 C) or 11 panels (-20 C), or compare DONGGUAN SUNWORTH SOLAR ENERGY CO LTD SW490M.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 454.2 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for TSEC TS66-BMH-490 H1 by TSEC grounded in CEC test data and NEC 690.7/690.8 limits.
How many TSEC TS66-BMH-490 H1 panels fit on a 600 V winter solar string?
At -10 C (14 F), TSEC TS66-BMH-490 H1 cold Voc rises from 45.25 V to 49.84 V (beta_Voc -0.29%/C), capping a 600 V string at 12 panels (598.1 V).
How much roof area does an 8 kW array of TSEC TS66-BMH-490 H1 need?
An 8 kW DC system uses 17 TSEC TS66-BMH-490 H1 modules (8,330 W STC / 7,721 W PTC), covering roughly 430 sq ft and saving ~$2,085/yr at 18.54 c/kWh.
How does TSEC TS66-BMH-490 H1 compare against DONGGUAN SUNWORTH SOLAR ENERGY CO LTD SW490M?
TSEC TS66-BMH-490 H1 outputs 490.0 W STC (45.25 V Voc, rank #4,659 of 21,677), while DONGGUAN SUNWORTH SOLAR ENERGY CO LTD SW490M delivers 490.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)