TSEC TS60-AMH-365 H1 is a 365.0 W STC (338.8 W PTC) Mono-c-Si solar module ranking #12,044 of 21,677 CEC listings (below all-CEC median; higher than 42.9% of peers). It delivers 20.17% efficiency, 40.7 V Voc at 25 C, and 45.12 V cold Voc at -10 C (13 panels max per 600 V string).
- STC Wattage
- 365.0 W
- PTC Wattage
- 338.8 W
- Voc @ 25C
- 40.7 V
- Efficiency
- 20.17%
How Does TSEC TS60-AMH-365 H1 Compare Against Peer CEC Listings?
How TSEC TSEC TS60-AMH-365 H1 handles rooftop heat (338.8 W PTC), 8 kW sizing, and cold winter string voltage.
For NEC string engineering, TSEC TS60-AMH-365 H1 exhibits 11.43 A short-circuit current, requiring a 17.83 A (156%) conductor rating and 20 A OCPD under NEC 690.8. Ranked #12,044 of 21,677 (45.0 W below the 410.0 W Mono-c-Si median), this compact residential or specialty off-grid module covers 39.8 m2 for an 8 kW system (28 panels for 10 kW). Mid-range 40.7 V open-circuit voltage allows up to 13 panels per 600 V string at 14 F.
Where Does TSEC TS60-AMH-365 H1 Fall Across Listed CEC Models?
Where TSEC TS60-AMH-365 H1 (365.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define TSEC TS60-AMH-365 H1?
Percentile placement of TSEC TS60-AMH-365 H1 across power density (201.7 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for TSEC TS60-AMH-365 H1?
Four critical engineering numbers homeowners and solar installers check first when reviewing TSEC TS60-AMH-365 H1 specifications. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.
365.0 W STC · Higher Than 42.9%
365.0 W STC (-20.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
20.17% Aperture Efficiency
Power density 201.7 W/m2 (0.26 percentage points above 19.91% CEC median). PTC/STC ratio: 92.8% (rank #10,898).
13 Panels Max @ -10 C (600 V)
Cold Voc reaches 45.12 V at -10 C (586.6 V string) and 46.38 V at -20 C (12 max).
22 Panels = 8,030 W STC
Occupies 39.8 m2 (429 sq ft) producing 7,454 W PTC; NEC 690.8 OCPD floor is 17.83 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 40.7 * (1 + (-0.31/100) * (-10 - 25)) = 45.12 V | OCPD = 1.56 * 11.43 = 17.83 A
Inputs from CEC Modules.csv for TSEC TS60-AMH-365 H1: Voc=40.7 V, beta_Voc=-0.31%/C, Isc=11.43 A, STC=365.0 W, Area=1.81 m2.
Result: 13 panels max on 600 V (586.6 V); 22 panels for 8 kW (429 sq ft).
What Are the Published CEC Specifications for TSEC TS60-AMH-365 H1?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for TSEC TS60-AMH-365 H1.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 365.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 338.8 W (92.8% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 40.7 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 11.43 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 34.2 V / 10.68 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.31 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 20.17% (1.81 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Mono-c-Si) | Monofacial backsheet |
How Many TSEC TS60-AMH-365 H1 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using TSEC TS60-AMH-365 H1 (365.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 17 | 6.21 kW | 331 sq ft | $1,554 | $2,628 |
| 8 kW Class | 22 | 8.03 kW | 429 sq ft | $2,010 | $3,398 |
| 10 kW Class | 28 | 10.22 kW | 546 sq ft | $2,558 | $4,325 |
Which Sibling Wattage & Trim Variants Belong to This TSEC Series?
All closely matched TSEC wattages and cosmetic trims sharing the TSEC TS60-AMH-365 H1 architecture. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| TSEC TS60-AMH-355 H1 | 355.0 W | 329.3 W | 40.3 V | 33.8 V | 19.61% |
| TSEC TS60-AMH-360 H1 | 360.0 W | 334.0 W | 40.5 V | 34.0 V | 19.89% |
| TSEC TS60-AMH-365 H1 | 365.0 W | 338.8 W | 40.7 V | 34.2 V | 20.17% |
| TSEC TS60-AMH-370 H1 | 370.0 W | 343.6 W | 40.9 V | 34.4 V | 20.44% |
How Many TSEC TS60-AMH-365 H1 Modules Fit in a Cold-Weather String?
Maximum series module counts for TSEC TS60-AMH-365 H1 from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 46.38 V | 12 panels | 556.6 V | 21 panels |
| -10 C (14 F) | 45.12 V | 13 panels | 586.6 V | 22 panels |
| 0 C (32 F) | 43.85 V | 13 panels | 570.1 V | 22 panels |
| 25 C (77 F STC) | 40.7 V | 14 panels | 569.8 V | 24 panels |
Which Cross-Brand Solar Modules Compare Closest to TSEC TS60-AMH-365 H1?
Alternative CEC solar modules from competing brands near TSEC TS60-AMH-365 H1 (365.0 W), including Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-365W.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-365W Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd |
365.0 W | Tie (0 W) | 40.7 V | 20.51% | 92.6% |
| Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-HC-365W Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd |
365.0 W | Tie (0 W) | 40.7 V | 20.17% | 92.3% |
| Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-HC-365W Black Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd |
365.0 W | Tie (0 W) | 40.7 V | 19.95% | 93.3% |
| Aptos Solar Technology LLC DNA-120-MF26-365W Aptos Solar Technology LLC |
365.0 W | Tie (0 W) | 40.7 V | 20.74% | 91.3% |
What Are the Design Limits and Best-Fit Uses for TSEC TS60-AMH-365 H1?
Evaluate TSEC TS60-AMH-365 H1 (365.0 W STC, 40.7 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), TSEC TS60-AMH-365 H1 reaches 46.38 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
- Footprint constraint: 22 panels for an 8 kW build require 429 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 22 panels (429 sq ft).
- 2026 tax credit baseline: cash residential installs of TSEC TS60-AMH-365 H1 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
TSEC TS60-AMH-365 H1 8 kW Residential Fit
Needs 22 modules (429 sq ft) with a 20 A string OCPD, offsetting ~$2,010/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 13 panels (-10 C) or 12 panels (-20 C), or compare Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-365W.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 338.8 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for TSEC TS60-AMH-365 H1 by TSEC grounded in CEC test data and NEC 690.7/690.8 limits.
Why is TSEC TS60-AMH-365 H1 PTC wattage (338.8 W) lower than STC (365.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 338.8 W PTC (92.8% retention) across TSEC TS60-AMH-365 H1's 1.81 m2 aperture.
Who should skip TSEC TS60-AMH-365 H1 on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 22 TSEC TS60-AMH-365 H1 panels (429 sq ft) leave unusable roof gaps vs. Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-365W.
What is the 1,000 V commercial string limit for TSEC TS60-AMH-365 H1?
On 1,000 V commercial inverters at -10 C (45.12 V cold Voc), TSEC TS60-AMH-365 H1 fits up to 22 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting TSEC TS60-AMH-365 H1.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)