Manufacturer: TSEC Registry: CEC Verified Engineering Specification

TSEC TS54-BMH-405 H1 is a 405.0 W STC (375.4 W PTC) Mono-c-Si solar module ranking #8,961 of 21,677 CEC listings (top 43.4%; higher than 56.6% of peers). It delivers 20.88% efficiency, 37.06 V Voc at 25 C, and 40.82 V cold Voc at -10 C (14 panels max per 600 V string).

STC Wattage
405.0 W
PTC Wattage
375.4 W
Voc @ 25C
37.06 V
Efficiency
20.88%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does TSEC TS54-BMH-405 H1 Compare Against Peer CEC Listings?

Engineering position of TSEC TS54-BMH-405 H1 (405.0 W STC) vs. CSI Solar Co Ltd CS6R-405MS-HL {Blk} across 5,889 CEC Mono-c-Si solar modules.

Built with 54 Mono-c-Si cells, TSEC TS54-BMH-405 H1 pairs strong 92.7% PTC-to-STC heat retention (#11,468 of 21,677) with 37.06 V nominal Voc. An 8 kW residential build (8,100 W DC, 7,508 W PTC) saves ~$2,027/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer CSI Solar Co Ltd CS6R-405MS-HL {Blk} offers a 405.0 W alternative.

Where Does TSEC TS54-BMH-405 H1 Fall Across Listed CEC Models?

Plots TSEC TS54-BMH-405 H1 at 405.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where TSEC TS54-BMH-405 H1 (405.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCTSEC TS54-BMH-405 : 405.0 W

What Dataset Percentiles Define TSEC TS54-BMH-405 H1?

Benchmarks TSEC TS54-BMH-405 H1 on STC wattage, thermal PTC/STC retention, and 20.88 aperture conversion efficiency against CEC peers.

TSEC TS54-BMH-405 H1 Engineering BenchmarksPercentile comparison of TSEC TS54-BMH-405 H1 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage405.0 WPTC/STC Retention92.7%Module Efficiency20.88%

What Do the Dataset Ranks Show for TSEC TS54-BMH-405 H1?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for TSEC TS54-BMH-405 H1 by TSEC.

Rank #8,961 / 21,677

Top 43.4% STC Output

405.0 W STC (+20.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #6,925

20.88% Aperture Efficiency

Power density 208.8 W/m2 (0.97 percentage points above 19.91% CEC median). PTC/STC ratio: 92.7% (rank #11,468).

NEC 690.7 Limit

14 Panels Max @ -10 C (600 V)

Cold Voc reaches 40.82 V at -10 C (571.5 V string) and 41.9 V at -20 C (14 max).

8 kW Reference Array

20 Panels = 8,100 W STC

Occupies 38.8 m2 (418 sq ft) producing 7,508 W PTC; NEC 690.8 OCPD floor is 21.61 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 37.06 * (1 + (-0.29/100) * (-10 - 25)) = 40.82 V | OCPD = 1.56 * 13.85 = 21.61 A

Inputs from CEC Modules.csv for TSEC TS54-BMH-405 H1: Voc=37.06 V, beta_Voc=-0.29%/C, Isc=13.85 A, STC=405.0 W, Area=1.94 m2.

Result: 14 panels max on 600 V (571.5 V); 20 panels for 8 kW (418 sq ft).

What Are the Published CEC Specifications for TSEC TS54-BMH-405 H1?

Laboratory test ratings recorded for TSEC TS54-BMH-405 H1 (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for TSEC TS54-BMH-405 H1.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 405.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 375.4 W (92.7% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 37.06 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 13.85 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 30.52 V / 13.27 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.29 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 20.88% (1.94 m2) Array roof footprint density
Cell Count & Technology 54 cells (Mono-c-Si) Monofacial backsheet

How Many TSEC TS54-BMH-405 H1 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (418 sq ft at 8 kW), and estimated Year-1 electric bill offset for TSEC TS54-BMH-405 H1.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 15 6.08 kW 313 sq ft $1,522 $2,573
8 kW Class 20 8.1 kW 418 sq ft $2,027 $3,428
10 kW Class 25 10.12 kW 522 sq ft $2,533 $4,283

Which Sibling Wattage & Trim Variants Belong to This TSEC Series?

Sibling wattage bins and frame colors grouped with TSEC TS54-BMH-405 H1 under TSEC to prevent duplicate spec pages.

Sibling CEC listings grouped into the TSEC TS54-BMH-405 H1 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
TSEC TS54-BMH-400 H1 400.0 W 370.7 W 36.98 V 30.42 V 20.62%
TSEC TS54-BMH-405 H1 405.0 W 375.4 W 37.06 V 30.52 V 20.88%
TSEC TS54-BMH-410 H1 410.0 W 380.2 W 37.14 V 30.62 V 21.13%

How Many TSEC TS54-BMH-405 H1 Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for TSEC TS54-BMH-405 H1 (beta_Voc -0.29%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=37.06V and beta_Voc=-0.29%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 41.9 V 14 panels 586.6 V 23 panels
-10 C (14 F) 40.82 V 14 panels 571.5 V 24 panels
0 C (32 F) 39.75 V 15 panels 596.2 V 25 panels
25 C (77 F STC) 37.06 V 16 panels 593.0 V 26 panels

Which Cross-Brand Solar Modules Compare Closest to TSEC TS54-BMH-405 H1?

Closest cross-brand CEC competitors to TSEC TS54-BMH-405 H1 matched near 405.0 W STC and 37.06 V Voc, led by CSI Solar Co Ltd CS6R-405MS-HL {Blk}.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
CSI Solar Co Ltd CS6R-405MS-HL {Blk}
CSI Solar Co Ltd
405.0 W Tie (0 W) 37.0 V 20.77% 94.2%
Changzhou EGing Photovoltaic Technology Co Ltd EG-405M54-HLV
Changzhou EGing Photovoltaic Technology Co Ltd
405.0 W Tie (0 W) 37.2 V 20.77% 93.8%
CertainTeed CTM10405HC11-06
CertainTeed
405.0 W Tie (0 W) 37.23 V 20.77% 93.8%
AMPS Solar AMPS-405P-54BB
AMPS Solar
405.0 W Tie (0 W) 37.25 V 20.88% 94.2%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for TSEC TS54-BMH-405 H1?

Evaluate TSEC TS54-BMH-405 H1 (405.0 W STC, 37.06 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), TSEC TS54-BMH-405 H1 reaches 41.9 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 20 panels for an 8 kW build require 418 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (418 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of TSEC TS54-BMH-405 H1 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

TSEC TS54-BMH-405 H1 8 kW Residential Fit

Needs 20 modules (418 sq ft) with a 25 A string OCPD, offsetting ~$2,027/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare CSI Solar Co Ltd CS6R-405MS-HL {Blk}.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 375.4 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for TSEC TS54-BMH-405 H1 by TSEC grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for TSEC TS54-BMH-405 H1?

Multiplying TSEC TS54-BMH-405 H1's 13.85 A short-circuit current by 1.56 equals 21.61 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.

Can TSEC TS54-BMH-405 H1 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 40.82 V cold Voc at 14 F and handles 13.85 A Isc; string inverters cap TSEC TS54-BMH-405 H1 at 14 panels on 600 V.

Is TSEC TS54-BMH-405 H1 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of TSEC TS54-BMH-405 H1 rely on utility bill offset (~$2,027/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.